Catalog excerpts
Master Your Next Designs Data Sheet Version 1.0 • Emulate a wide range of channel loss with cascadable ISI traces with fine resolution • Real Nelco FR4 PC board material with known S21 • Differential channels compliant ISI channels (PCIe, • Small size The M8048A ISI Channels can be used to emulate channel loss in receiver test setups. A choice of 8 PC board traces with different lengths can be inserted into the signal path. The 8 trace lengths range from 7.7 inch (196 mm) to 34.4 inch (874 mm). By cascading the traces within one box or with the other box a wide range of channels can be emulated with very fine resolution steps. With their small size the ISI channels can be located closely to the device under test. The cascadable ISI channels are complemented by Agilent's compliance channels for SATA, DisplayPort, PCI Express, and HDMI. Agilent Technologies
Open the catalog to page 1Emulate channel loss The channel loss between transmitter and receiver is a critical element for the receiver test for all electrical multi gigabit serial interfaces. The channel loss depends primarily on the distance between transmitter and receiver and the electrical medium. The channel loss is typically defined by the S21 parameter in dB for certain frequencies. Some standards define the receiver test to include a certain channel loss in the test setup. M8048A offers a wide range of cascadable channels to emulate certain S21 parameter conditions in a repeatable and accurate way. Emulate...
Open the catalog to page 2Figure 3: Front panel view of M8048A option 001 (top) and M8041A option 002 (bottom). Trace lengths of Nelco FR 4 Insertion loss Typical values see figure 2 (excludes cables) Insertion loss for M8048A-801 cable Return loss Better than -16 dB at up to 10 GHz typical Better than -12 dB at up to 16 GHz typical see figure 4 Intra-pair skew Input impedance 100 Ω differential, 50 Ω single ended, ± 10% typical Max input voltage levels
Open the catalog to page 3Figure 4: Typical return loss (reflection) – example for trace 14.4”. Pattern PRBS 215-1 Data rate Trace length Figure 5: Typical ISI jitter values for all traces at PRBS 215 -1 pattern and selected data rates.
Open the catalog to page 4Figure 6: Rear panel view of M8048A-001 (left) and M8028A-002 (right). Table 6. General characteristics Operating temperature Storage temperature Operating humidity 15% to 95% relative humidity at 40ºC (non-condensing) Storage humidity 24% to 90% relative humidity at 65ºC (non-condensing) Physical dimensions (W x H x D) with connectors Bench top (with bumper): Warranty period 1 year return to Agilent Quality management 228 x 59 x 221 mm 9 x 2.3 x 8.7 inch Rack mount (without bumper): 213 x 44.5 x 221 mm 8.4 x 1.8 x 8.7 inch Specification assumptions The specifications in this document...
Open the catalog to page 5Related Agilent literature J-BERT M8020A High-Performance BERT Data Sheet N4915A-014 PCIe Compliance Channels Data Sheet N4915A-005 DisplayPort ISI Generator Data Sheet N4915-60001 SATA ISI Channel Data Sheet Ordering instructions Each M8048A option includes the following accessories by default: SMA matched cable pair for cascading ISI channels, functional test certificate, and certificate of conformance ISI channel, 4 short traces (7.7” to 12.8“) ISI channel, 4 long traces (14.4” to 34.4”) SMA matched cable pair for cascading channels, 0.4 m, ±5 ps (See figure 7) Recommended accessories:...
Open the catalog to page 6A personalized view into the information most relevant to you. Three-Year Warranty For more information on Agilent Technologies’ products, applications or services, please contact your local Agilent office. The complete list is available at: Agilent Assurance Plans Canada Brazil Mexico United States Beyond product specification, changing the ownership experience. Agilent is the only test and measurement company that offers three-year warranty on all instruments, worldwide. Five years of protection and no budgetary surprises to ensure your instruments are operating to specifications and you...
Open the catalog to page 7All Agilent Technologies - Life Sciences and Chemical catalogs and technical brochures
-
Agilent 280 Series AA Systems
12 Pages
-
Inorganic Standards
40 Pages
-
InfinityLab LC Supplies
148 Pages
-
General Chromatography
164 Pages
-
Sample Preparation (2018/2019)
144 Pages
-
MS500
12 Pages
-
FLAME ATOMIC ABSORPTION SPECTROSCOPY
104 Pages
-
Agilent training
27 Pages
-
AGILENT VACUUM PRODUCTS CATALOG
536 Pages
-
Vacuum Measurement Catalog
44 Pages
-
AGILENT ION Pumps
53 Pages
-
AGILENT DIFFUSION PUMPS
35 Pages
-
AGILENT Rotary Vane Pumps
29 Pages
-
Agilent InfinityLab LC Series
16 Pages
-
3100 fractionator
8 Pages
-
4200 MP-AES
12 Pages
-
Agilent GPC/SEC Solutions
12 Pages
-
Agilent?s biomass solutions
12 Pages
-
X-ray Crystallography
12 Pages
-
Agilent ProPulse NMR System
5 Pages
-
An autosampler like no other
4 Pages
-
Agilent U1450A/U1460A
19 Pages
-
Agilent B1507A
22 Pages
-
Agilent M9703A
16 Pages
-
W1905 Radar Model Library
16 Pages
-
Agilent J-BERT M8020A
27 Pages
-
Agilent N8900 Series
10 Pages
-
I/O Hardware
16 Pages
-
Advanced Design System
16 Pages
-
RF & Microwave Attenuators
4 Pages
-
E4980AL Precision LCR Meter
8 Pages
-
FieldFox Handheld Analyzers
8 Pages
-
AFM/SPM Accessories
20 Pages
-
VEE 9.32
24 Pages
-
89600 VSA Software
9 Pages
-
Command Expert
2 Pages
-
E5061B Network Analyzer
8 Pages
-
E5071C ENA Network Analyzers
18 Pages
-
N9038A MXE EMI Receiver
2 Pages
-
N9322C Basic Spectrum Analyzer
10 Pages
-
Digital Multimeters
25 Pages
-
M9361A PXI Downconverter
2 Pages
-
Power Meters and Power Sensors
34 Pages
-
E7515A UXM Wireless Test Set
2 Pages
-
Agilent Power Products
31 Pages
-
E5063A Network Analyzer
8 Pages
-
Leak Detection Catalog
41 Pages
-
Agilent 7820A GC brochure
8 Pages
-
Agilent GC-MSD and QTOF
96 Pages
-
Agilent GC-MSD 5977
39 Pages
-
Agilent Intro BERLIN
24 Pages
-
1290 Infinity Quaternary LC
24 Pages
-
1260 Infinity Bio-inert
26 Pages
Archived catalogs
-
Diffusion Pumps Catalog
37 Pages