Leak Detection Catalog

Leak Detection Catalog
1 / 41 PagesView full catalog

Leak Detection Catalog

Product catalog summary
Agilent Leak Detection Overview
Agilent offers comprehensive leak detection solutions aimed at enhancing productivity and uptime in manufacturing and research settings. Key components include global applications support, high-performance instruments, and industry-leading service and support.
Leak Detection Instruments
The VS Series features easy operation with automated start-up and calibration, a color touch screen for programming, and wireless remote options. The VS C15 is compact and integrates with various interfaces, while the 959 Leak Detector is rugged for industrial use, offering automatic pump down and overpressure protection.
Accessories and Options
Agilent provides accessories like wireless remotes and the Leak Test Data Wizard for data management, enhancing system functionality and ease of use.
Global Support Network
Agilent offers extensive global support with service engineers, flexible service plans, and technical support to ensure smooth operation. Application notes and literature guide users in selecting appropriate leak detection methods.
Training and Support Programs
Agilent provides training programs and a field and factory support program to maximize user investment.
Advantages of Helium Leak Detection
Helium leak detection is noted for its sensitivity and efficiency, suitable for a wide range of applications.
Leak Detection Methods and Applications
Various methods and applications are discussed, highlighting the versatility of Agilent's solutions.
Design and Application Considerations
Guidance is provided for designing and applying leak detection systems to ensure optimal performance.
Technical Notes
Technical specifications and compliance standards for the VS Series and other models are detailed for user selection.
Key Features of VS Series
  • Easy-to-Use: Two-button operation with automated start-up and calibration.
  • Powerful: Equipped with a state-of-the-art spectrometer and vacuum system.
  • Versatile: Multiple configurations and language options.
  • Dependable: Robust design for reliable operation.
  • Portable: Wireless remote control for testing over 100 meters.
Applications
  • Industrial Process Tools: Suitable for vacuum furnaces and coating systems.
  • Power Generation: Effective for detecting leaks in condensers and heat exchangers.
  • High Energy Physics: Ideal for accelerators and beam lines.
  • Semiconductor Production: Meets needs of semiconductor processing equipment.
  • Small Parts Manufacturing: Enhances production efficiency.
  • General R&D: Portable and versatile for research labs.
Technical Specifications
  • VS C15 Component Leak Detector: Compact design, automated calibration, wide interface options.
  • Agilent 959: Rugged design with high roughing speeds.
  • Agilent PHD-4: Portable detector with high sensitivity to helium.
Ordering Information
Includes part numbers and descriptions for configurations, accessories, and replacement parts.
Specifications and Features of PHD-4
High sensitivity to helium, excellent selectivity, and user-friendly design. Portable and versatile for various applications.
Applications of PHD-4
Used in water heating and cooling pipes, airplane fuel tanks, underground pipes, and large vessels.
Pumps and Accessories
Details on DS Series Rotary Vane Pumps, MacroTorr Turbo pumps, and TriScroll Series Dry Scroll Pumps. Accessories include calibrated helium leaks and probe kits.
Training and Support
Agilent offers training programs for operation and maintenance, with various accessories to enhance capabilities.
Overview of PHD-4 Extension Probe
Designed for detecting leaks in hard-to-reach areas, with a small funnel tip for helium conveyance.
Support and Services
Agilent provides onsite integration support, technical support, and a trade-up program for older units.
Training Programs
Courses cover vacuum fundamentals, operation, tuning, calibration, and maintenance of leak detectors.
Advantages of Helium Leak Detection
Helium is non-toxic, inert, and non-flammable, effective in locating and quantifying leaks.
Conclusion
The document serves as a guide for selecting, ordering, and maintaining leak detection equipment, providing training resources to enhance operational efficiency.
Introduction to Leak Detection Methods
Outlines different methods and technologies for leak detection, focusing on helium as a tracer gas.
Halogen Gas Detection
Used in air conditioning and cooling industries, but impractical due to environmental concerns.
Mass Spectrometer Leak Detector (MSLD)
Comprehensive system for detecting leaks using helium.
Selective Ion Pump Detection (SIPD)
Used in PHD-4 Portable Helium Detector for sensitive helium detection.
Leak Testing Methods
Includes Vacuum Testing, Pressure Testing, and Accumulation Testing.
System Leak Test Methods
Systems should be tested under operational conditions.
Applications of Leak Detection
Vital in quality control, maintenance, and system integration across various industries.
Guidelines for Selecting Leak Detection Methods
Table provides guidance based on industry applications.
Key Sections
1. Leak Detection Methods: Vacuum and Pressure methods are outlined.
2. Technology & Models: Various models of mass spectrometers and leak detectors are mentioned.
3. Design and Application Considerations: Discusses helium pumping speed and detection efficiency.
4. Selecting Proper Connections: Importance of choosing appropriate connections.
5. Evacuation Process: Guidance on evacuating parts for leak testing.
6. Parallel Operation: Use of auxiliary pumping stations for large volumes.
7. Helium Consumption: Strategies for reducing helium consumption.
8. Equations for Helium Leak Detection: Provides equations for critical parameters.
9. Conversion Tables: Tables for converting units of pumping speed, flow/leak rate, pressure, and volume.
See more

Catalog excerpts

Leak Detection Catalog-1

Agilent Leak Detection 2-3 Leak Detection Instruments Global Support Network Field & Factory Support Program Advantages of Helium Leak Detection Leak Detection Methods Typical Applications Design and Application Considerations Technical Notes

 Open the catalog to page 1
Leak Detection Catalog-2

Agilent Leak Detection The Agilent Advantage Rigorous standards in today’s manufacturing and research and development environments require complete leak detection solutions. The Agilent Advantage offers a comprehensive solution the primary component of which is our committment to Maximize your Productivity and Uptime. Key components of The Agilent Advantage: • Global Applications Support • High Performance Instruments • Industry Leading Service and Support VS Series • Easy, two button operation with fully automated start-up and calibration. • Color touch screen display allows users to program...

 Open the catalog to page 2
Leak Detection Catalog-3

Leak Detection Application Notes and Literature Our offering of technical information guides you to the most appropriate leak detection method or system design for your specific application. • Application notes are available at no cost. • Agilent handbooks on leak detection principles, operation, and techniques. Global Applications Support Maximize Your Productivity and System Uptime Industry Leading Service & Support Get the Most from Your Investment • Extensive network of service engineers available to meet your needs. • Flexible, comprehensive service plans provide service and support for...

 Open the catalog to page 3
Leak Detection Catalog-4

Agilent Leak Detection Instruments Mass Spectrometer Leak Detectors (MSLD) Portable VS PR02 VS PD03 Nominal Pumping Speed Sensitivity Ranges Primary Pumps Minimum Detectable Leak Maximum Test Port Pressure Automated or Manual (Internal or External) Background Suppression Push Button Initiated Auto Zero, and Auto Zero < Zero Function Communication Interface RS232 and analog (standard), Discrete IO (optional) 5 Set Points Standard, N/O or N/C; 3 Leak Rate, 1 Pressure, 1 Audio Remote Display/Control Shipping Weight (base unit)

 Open the catalog to page 4
Leak Detection Catalog-5

Leak Detection Selective Ion Pump Detector Component VS C15 Dry Scroll or Rotary Vane 4 working ranges covering Automated or manual (internal or external) Auto zero, and auto zero < zero function RS232, analog, discrete IO, and Profinet Standard Analog and RS-232 Serial Output 5 set points: 4 leak rate and/or pressure, 1 audio Leak Detection

 Open the catalog to page 5
Leak Detection Catalog-6

Agilent Leak Detection Instruments Agilent VS Series Dimensions: millimeters (inches) VS Series leak detectors combine the simplicity of two-button operation with advanced system intelligence. Start and vent buttons permit simple day-to day operation. User friendly software offers intuitive navigation to vast system capabilities. Programmable test sequences simplify daily operation, minimize operator error, and maximize production effieciency. The TFT style touch screen features high definition and brightness with wide viewing angles. Setup for worldwide use, these leak detectors can be operated...

 Open the catalog to page 6
Leak Detection Catalog-7

Leak Detection Ordering Information Shipping Weight kg (lbs) Accessories Oil mist eliminator, PR02 only Wireless remote, base unit Hand-held remote control Discrete I/O Leak Test Data Wizard software 1⅛ in. compression test port Power probe sniffer, NW25 Power Cords Rating 16A/250 V 15A/125 V 20A/250 V 20A/125 V 15A/250 V 15A/250 V Country Where Used China Japan, Philippines, Thailand North America North America UK, Ireland, Hong-Kong, Malaysia, Singapore Europe, Korea, Indonesia Part Number Denmark, Switzerland Israel India, South Africa Australia, New Zealand Support Plans – see page 26 Additional...

 Open the catalog to page 7
Leak Detection Catalog-8

Agilent Leak Detection Instruments Agilent Wireless Remote for VS Series Leak Detectors Leaks in large systems often occur far from the leak detector. Wired remote controls have sought to address this problem, but impedance and the cumbersome nature of long cables are often limiting factors. For many applications these traditional wired remotes provide little benefit. By utilizing modern wireless technology, leak testing hard-to-reach locations is now much easier, and can be performed at much greater distances of up to 100 meters. Applications in large systems which have traditinally required...

 Open the catalog to page 8
Leak Detection Catalog-9

Leak Detection Leak Test Data Wizard for VS Series Leak Detectors Capturing and analyzing leak test data are increasingly critical to the leak test process. Aggressive manufacturing yield and efficiency targets, demanding quality control procedures, and ISO and regulatory compliance requirements have created a need for a capable, user-friendly data management tool. To meet this need, Agilent has designed the Leak Test Data Wizard, a comprehensive data management software package for use with our VS Series mass spectrometer leak detectors. The Leak Test Data Wizard is a flexible PC based, graphic-rich...

 Open the catalog to page 9
Leak Detection Catalog-10

VS Series Features and Benefits Easy-to-Use – Two Button Operation VS Series Leak Detectors combine the simplicity of two-button operation with advanced expert system intelligence. • Fully automated start-up and calibration maximizes productivity • Intuitive menu structure is easy to navigate • Programmable test sequences improves testing efficiency • Color touch screen provides excellent clarity, even at wide angles Powerful – Broad Range of Test Methods The state-of-the-art spectrometer and vacuum system design provides powerful capability, enabling a broad range of test methods for specific...

 Open the catalog to page 10
Leak Detection Catalog-11

Leak Detection Industrial Process Tools VS Series Leak Detectors can help rid your process tool of costly and inefficient leaks. Robust system features assure reliable operation in the most challenging industrial environments. Superior pumping characteristics such as high inlet pressure tolerance and split flow capability deliver fast response and clean-up times. Wireless remote control enables single-person leak testing of even the largest systems. • Vacuum furnaces • Coating systems • Electronic beam welders Power Generation Leaks within power plant condensers can cause a significant loss of...

 Open the catalog to page 11

All Agilent Technologies - Life Sciences and Chemical catalogs and technical brochures

  1. MS500

    12  Pages

  2. 4200 MP-AES

    12  Pages

  3. Agilent B1507A

    22  Pages

  4. Agilent M9703A

    16  Pages

  5. I/O Hardware

    16  Pages

  6. VEE 9.32

    24  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.