Your Essential Resource for
Open the catalog to page 1ACROSS THE LAB, AROUND THE WORLD, WITH YOU EVERY STEP OF THE WAY. Real stories from the lab. Whatever your lab needs, Agilent CrossLab is ready to partner with you to create new and transformative opportunities. Together, we’ll support your scientific and business goals with superior laboratory services, software, and consumables from Agilent. A direct connection to a global team of service experts delivers vital, actionable insights at every level for your lab. Our solutions maximize performance, reduce complexity, and drive improved economic, operational, and measurable outcomes. And our innovative...
Open the catalog to page 2MAXIMIZE THE EFFICIENCY OF YOUR LC WORKFLOWS The InfinityLab family is an optimized portfolio of LC instruments, columns, and supplies designed to work together seamlessly for maximum efficiency and performance–regardless of application area. Supporting your efforts to increase your analytical, instrument, and laboratory efficiency in your everyday work. Achieve optimal LC performance with simplified laboratory solutions From routine analysis to cutting-edge research, the InfinityLab family gives you the ability to: • Maximize performance and efficiency of your LC workflows with the latest innovations...
Open the catalog to page 3AGILENT ESSENTIAL CHROMATOGRAPHY AND SPECTROSCOPY CATALOG—INFINITYLAB LC SUPPLIES
Open the catalog to page 4FEATURED PRODUCTS Featured Products Agilent 1260 Infinity II Prime LC Achieve the highest convenience for your everyday analysis The Agilent 1260 Infinity II Prime LC is the most capable and convenient LC within the 1260 Infinity II LC portfolio. Featuring an extended pressure range of up to 800 bar, enhanced quaternary mixing, and superior Agilent 1290 Infinity II technology it offers the highest ease-of-use and functionality for your everyday analysis. • The 1260 Infinity II Flexible pump features an extended pressure range of up to 800 bar and superior quaternary mixing. Perfectly matching...
Open the catalog to page 5FEATURED PRODUCTS InfinityLab Capillary and Convenience Kits Quickly access the essentials you need for optimal performance of your InfinityLab LC Series instrument. Turn to Page 3 or visit www.agilent.com/chem/capillaryfittingkits InfinityLab Stay Safe Caps Simplify every day solvent handling, safely and more reliably, with Stay Safe caps and ergonomic solvent bottles. Turn to Pages 25–26 or visit www.agilent.com/chem/staysafecaps InfinityLab Quick Connect/Quick Turn Fittings These award-winning fittings offer easy, leak-proof connections for every user, every time. Turn to Pages 103–106 or...
Open the catalog to page 6INSTRUMENT AND MODULE KITS InfinityLab Convenience Kits A carefully selected portfolio of InfinityLab supplies for efficient ramp up usage of new InfinityLab LC Series instruments. InfinityLab Capillary Kits A complete set of system capillaries, including InfinityLab fittings available in 0.17 and 0.12 mm internal diameters. System Kits Description Kit Contents Part No. Convenience Kits InfinityLab convenience kit, Includes solvent bottles 1 L (3 clear, 1 amber), identification rings and 5067-6617 for 1260 Infinity II LC removable stickers for solvent bottles, vials (2 mL) clear with...
Open the catalog to page 7INSTRUMENT AND MODULE KITS Preventive Maintenance Kits Noisy baselines. Shorter column life. Lower analytical sensitivity. Variable retention times. Any – or all – of these problems can be caused by a lack of preventive maintenance. That’s why it’s critical to set up an LC instrument maintenance program, and to keep essential supplies in stock for regular replacement of worn or damaged components. You can keep LC pumps, autosamplers, and detectors operating at their best with Agilent preventive maintenance kits. These kits contain the seals, frits, stators, fittings, connections, and other components...
Open the catalog to page 8INSTRUMENT AND MODULE KITS Routine Pump Maintenance Procedures Symptom Solvent dripping out of waste outlet when valve closed Leak on pump head Exchange the purge valve frit or the purge valve Pressure ripple unstable Dirty active inlet valve cartridge Run leak test for verification and exchange the active inlet valve cartridge Leak on pump head Run leak test for verification and exchange the outlet ball valve sieve or the complete valve Gradient performance problems, intermittent pressure fluctuations Solvent filter is blocked Change the solvent filter A pressure drop of > 10 bar across the...
Open the catalog to page 9INSTRUMENT AND MODULE KITS Pump Kits Description Kit Contents Part No. Preventive maintenance kit, Includes PTFE pump seals (4/pk), seal caps G1312-68730 for 1100/1200 binary pump (400 bar) (3/pk), PTFE frits (5/pk), film washers (4/pk) Preventive maintenance kit, Includes PTFE pump seals (4/pk), seal caps G1312-68741 for 1260 Infinity LC binary pump (600 bar) (3/pk), PTFE frits (5/pk), film washers (4/pk) Preventive maintenance kit, for 1100/1200 Includes filter cup, seal prep flange (4/pk), G1361-68710 and 1260 Infinity LC preparative pump filter assembly, peristaltic...
Open the catalog to page 10Description Kit Contents Part No. Instrument Tool Kits 1290 Infinity II LC tool kit Includes hex key set, seal insert tool, hex driver G7120-68708 slitted (3/pk), wrenches, plastic syringe, syringe adapter, blanking nut Compact tool kit Includes tool for 1/8 nut, seal insert tool, wrench G4296-68715 0.25 inch to 0.31 inch, open wrench 14 mm, hex key (2.5 mm, 4 mm), 9/64 inch, wrench 0.50 inch to 0.56 inch 1290 Infinity pump service kit Includes pump seal exchange tool, torque 5067-4699 1290 Infinity pump service kit, for pumps with Long Life and Easy Maintenance pump heads...
Open the catalog to page 11INSTRUMENT AND MODULE KITS Procedure When to Perform Time Required Exchanging the needle assembly When needle shows indication of damage or blockage 15 minutes Exchanging the seat assembly When the seat shows indication of damage or blockage 10 minutes Exchanging the metering seal When autosampler reproducibility indicates seal wear 30 minutes Autosampler KitsDescription Kit Contents Starter Kits Start-up kit for Includes Vespel rotor seal, needle seat, needle, metering seals (2/pk) G1313A, G1329A and finger caps (15/pk) autosamplers Preventive Maintenance...
Open the catalog to page 1212 Pages
40 Pages
164 Pages
144 Pages
12 Pages
104 Pages
27 Pages
536 Pages
44 Pages
53 Pages
35 Pages
29 Pages
16 Pages
8 Pages
12 Pages
12 Pages
12 Pages
12 Pages
5 Pages
4 Pages
19 Pages
22 Pages
16 Pages
16 Pages
7 Pages
27 Pages
10 Pages
16 Pages
16 Pages
4 Pages
8 Pages
8 Pages
20 Pages
24 Pages
9 Pages
2 Pages
8 Pages
18 Pages
2 Pages
10 Pages
25 Pages
2 Pages
34 Pages
2 Pages
31 Pages
8 Pages
41 Pages
8 Pages
96 Pages
39 Pages
24 Pages
24 Pages
26 Pages
37 Pages