Infiniium DCA-X 86100D Wide-Bandwidth Oscilloscope Mainframe and Modules
24Pages

{{requestButtons}}

Catalog excerpts

Infiniium DCA-X 86100D Wide-Bandwidth Oscilloscope Mainframe and Modules - 1

infiniium DCA-X Oscilloscope Mainframe See the TRUE performance of your designs. The 861 OOD DCA-X is the premier solution for accurate and precise measurements on high-speed digital designs from 50 Mb/s to over 80 Gb/s. Applications include: • Optical—Transceiver design and manufacturing compliance test • Electrical—ASIC/FPGA/IC design and channel characterization • TDR/TDT/S-parameter—Serial bus design, cable, and PCB channel The DCA-X provides powerful analysis and measurement insight for the novice and expert user alike: • Scope, eye diagram and mask testing • Jitter and amplitude analysis • Equalization, de-embedding, and embedding • Phase locked loop (PLL) analysis • Phase noise analysis

Open the catalog to page 1
Infiniium DCA-X 86100D Wide-Bandwidth Oscilloscope Mainframe and Modules - 2

Overview of the Infiniium DCA-X The 86100D DCA-X can be viewed as four powerful instruments in one: Scope mode Jitter mode A full function oscilloscope providing high-fidelity waveform characterization Eye/Mask mode Precision jitter, amplitude, and frequency analysis capability TDR/TDT mode A digital communication analyzer providing fast transmitter characterization using eye diagram analysis, calibrated reference receivers, and automated mask margin measurements Accurate time domain reflectometry/transmission impedance and S-Parameter measurements These basic instrument modes are further...

Open the catalog to page 2
Infiniium DCA-X 86100D Wide-Bandwidth Oscilloscope Mainframe and Modules - 3

The DCA-X provides users with a variety of benefits: Lower cost of test Improved margins, differentiated products Increased channel density and fast measurement functions and algorithms (such as fast Auto Scale and ER tuning) result in lower cost of test per port. • High density channel count configurations • Optimized algorithms for high volume manufacturing Standards are continually moving towards faster and faster data rates in response to market demands. As a result, data signals have shorter bit periods and faster edge speeds. In order for digital communication systems to approach...

Open the catalog to page 3
Infiniium DCA-X 86100D Wide-Bandwidth Oscilloscope Mainframe and Modules - 4

The 86100D Ininiium DCA-X Wide-Bandwidth Oscilloscope— Engineered for unmatched measurement accuracy, insight, and ease-of-use High-resolution touch screen display See your signal more clearly with a larger 10.4” XGA (1024 x 768) high-resolution color touch screen display Dual user interfaces A dual user interface comes standard. FlexDCA enables next generation measurement capability while the classic DCA-J user interface provides 100% backwards compatibility FlexDCA Remote Access Software The new user interface is also available as N1010A FlexDCA Remote Access Software, a PCbased...

Open the catalog to page 4
Infiniium DCA-X 86100D Wide-Bandwidth Oscilloscope Mainframe and Modules - 5

Dedicated mode buttons One-touch Mode buttons quickly conigure standards-based measurements Customizable controls Vertical gain and offset controls can be assigned to any channel or math function for quick and easy amplitude adjustments One-touch operation Customizable multipurpose key can be conigured to print/save screen shots, save waveforms or load a favorite setup. Analog control The User Knob controls any analog entry area that is active, making adjustments easier and faster than keying in numbers from a keypad. Easy-to-use marker controls Control multiple markers without lifting your...

Open the catalog to page 5
Infiniium DCA-X 86100D Wide-Bandwidth Oscilloscope Mainframe and Modules - 6

Precision measurements on high-speed digital designs from 50 Mb/s to over 80 Gb/s Applications include: Optical • Transceiver design and manufacturing compliance test Electrical • ASIC/FPGA/SERDES/IC design and characterization TDR/TDT/S-parameter • Serial bus design, cable and PCB characterization 86100D mainframe hardware options Trigger and timebase options1 • Option STR – Standard Trigger For basic eye diagram measurements • Option ETR – Enhanced Trigger For pattern waveform and more advanced measurements such as jitter analysis. Option ETR increases trigger bandwidth to > 13 GHz adds...

Open the catalog to page 6
Infiniium DCA-X 86100D Wide-Bandwidth Oscilloscope Mainframe and Modules - 7

Dual user interfaces (standard with every 86100D) The 86100D DCA-X includes two user interfaces for even greater ease-of-use and 100% backwards compatibility with the 86100C DCA-J. Switch between FlexDCA, the new vector-based interface, and the classic DCA user interface, at the touch of a button. FlexDCA user interface • De-embedding, embedding using Option SIM • Jitter on long patterns (PRBS31), DDPWS, J2, J9 using 86100D Options 200/401 • Graphical signal processing • Up to 64 simultaneous measurements “Classic” DCA user interface • Provides 100% backwards compatibility with the 86100C...

Open the catalog to page 7
Infiniium DCA-X 86100D Wide-Bandwidth Oscilloscope Mainframe and Modules - 8

Oscilloscope measurements (standard with every 86100D) Highest accuracy waveforms. Wide-bandwidth, lownoise, and low-jitter samples result in accurate waveform measurements. • Comprehensive time measurements such as rise time, fall time, jitter rms, jitter p-p • Amplitude measurements such as Vampl, Vpp, overshoot, Vrms, OMA • Display and measure simulated waveforms For more detailed information: www.agilent.com/find/86100D Time domain reflectometry/transmission (TDR/TDT) (86100D with 54754A and N1055A1) Precision impedance and S-parameter measurements on serial bus designs, cables, and...

Open the catalog to page 8
Infiniium DCA-X 86100D Wide-Bandwidth Oscilloscope Mainframe and Modules - 9

Jitter analysis (86100D-2001) As data rates increase in both electrical and optical applications, jitter is an ever increasing design and measurement challenge. The DCA-X provides: • Simple, one button execution of jitter analysis • Compliant, fast and accurate results on both optical and electrical signals • Automated jitter decomposition into: ◦ TJ/RJ/DJ/PJ/DDJ/ISI/DCD ◦ UJ/J2/ J5/J9/DDPWS and more… ◦ Bounded Uncorrelated Jitter (BUJ) analysis For more detailed information: www.agilent.com/find/86100D-200 1 Amplitude and noise analysis/RIN/Q-Factor (86100D-3002) In addition to jitter,...

Open the catalog to page 9
Infiniium DCA-X 86100D Wide-Bandwidth Oscilloscope Mainframe and Modules - 10

861OOD DCA-X overview (continued) De-embedding/embedding capability Improve insight and design margins and comply with new standards based measurements. InfiniiSim-DCA provides an intuitive graphical interface that helps users: • Improve margin by removing signal degradation caused by fixtures and cables (de-embedding) • Simulate the signal at the end of a user-defined fixture • Predict performance at a location you cannot directly • Any measurement available for live signals can also be performed on simulated signals (jitter, waveform, eye For more detailed information: File Qmlral Setup...

Open the catalog to page 10

All Agilent Technologies - Life Sciences and Chemical catalogs and technical brochures

  1. MS500

    12 Pages

  2. 4200 MP-AES

    12 Pages

  3. Agilent B1507A

    22 Pages

  4. Agilent M9703A

    16 Pages

  5. I/O Hardware

    16 Pages

  6. VEE 9.32

    24 Pages

Archived catalogs