High productivity vapor generation with the VGA 77 accessory • • Technical Overview Agilent's fully automated, modular VGA 77 Vapor Generation Accessory is an optional accessory for the 200 Series Atomic Absorption Spectrometers. It is ideal for rapid trace level determinations of mercury (using the proven cold vapor technique) and other hydride-forming elements at parts-per-billion (pg/L) concentrations. The VGA 77 offers: • The convenience of flame AA determinations • Unmatched precision at ppb levels • Ease-of-use, flexibility and automation
Open the catalog to page 1The continuous flow VGA 77 offers the convenience of flame AA operation, while delivering exceptional precision with total flexibility and automation. Benefits of the VGA 77 include: • High sensitivity • Precisions of 1-2 % RSD at ppb levels, achieved using integration of the steady state signal for a few seconds • High sample throughput—results are achieved in less than 1 minute allowing determination of up to 70 samples/hour • Simple operation—the integral pump provides continuous flow conditions with automatic reagent addition • Enhanced stability—the continuous flow conditions ensure a...
Open the catalog to page 2• Greater productivity—samples only need to be aspirated once to obtain precise results from multiple replicates. Flow injection produces transient signals, requiring separate injections for each replicate reading. Each replicate consumes several milliliters of sample to ensure the injection loop is filled. This reduces sample throughput and increases sample consumption • Simple and automatic operation—each sample is automatically combined with a continuous flow of acid and reagents Table 1. Typical performance # with flow through cell * using Agilent high intensity UltrAA lamps Unattended hydride...
Open the catalog to page 3Ordering information For ordering information or for more information about our products and services, please consult your local Agilent office or supplier, or see the Agilent website at: www.agilent.com. www.agilent.com Agilent shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance or use of this material. Information, descriptions, and specifications in this publication are subject to change without notice. © Agilent Technologies, Inc. 2016 Published May 4, 2016 Publication number: 5990-6710EN
Open the catalog to page 412 Pages
40 Pages
148 Pages
164 Pages
144 Pages
12 Pages
104 Pages
27 Pages
536 Pages
44 Pages
53 Pages
35 Pages
29 Pages
16 Pages
8 Pages
12 Pages
12 Pages
12 Pages
12 Pages
5 Pages
4 Pages
19 Pages
22 Pages
16 Pages
16 Pages
7 Pages
27 Pages
10 Pages
16 Pages
16 Pages
4 Pages
8 Pages
8 Pages
20 Pages
24 Pages
9 Pages
2 Pages
8 Pages
18 Pages
2 Pages
10 Pages
25 Pages
2 Pages
34 Pages
2 Pages
31 Pages
8 Pages
41 Pages
8 Pages
96 Pages
39 Pages
24 Pages
24 Pages
26 Pages
37 Pages