Atomic Absorption Spectrometers Productive, Precise, Reliable. Agilent 200 series AA systems
Open the catalog to page 1Productive, Precise, Reliable. Agilent’s AA range is productive, user-friendly, and exceptionally reliable. The instruments deliver the high performance that analysts require, while being equally at home in routine laboratories where reliability and simple operation are vital. A family of atomic absorption solutions –– he Agilent 240 AA combines flexibility with reliable T hardware, providing budget-sensitive users with a high-performance AA for routine flame/furnace/vapor analyses. –– he Agilent 240FS/280FS AA are fast and productive T flame AA systems, with Fast Sequential operation...
Open the catalog to page 2Agilent is committed to providing solutions for your application. We have the technology, platforms, and expert guidance you need to be successful. Industrial Chemical and Environmental Food and Metals/mining petrochemical agriculture Chemical analysis of cement Zn and Sb in paper Ca, Cr, Cu, Fe, K, Mg, and Na in plating solutions (fatty acid methyl esters) Ca, and K in brines Pb and Mn in unleaded (SIPS accessory provides gasoline automated calibration and online sample dilution) Wear metals in used oils Pb in airborne particulates Additives (e.g. Ba, Ca, Mn, and Zn) in fresh lubricating...
Open the catalog to page 3Fast Sequential Flame AA Achieve the productivity and speed of sequential ICP with Agilent’s Fast Sequential (FS) AA systems. Fast Sequential mode will: Boost productivity and slash running costs –– Determine the concentration of all elements from a single aspiration of each sample –– Halve your analysis time by reducing sample analysis delays –– Reduce sample consumption—with less delay throughout analysis and less sample waste –– Save labor and reduce running costs—the more elements you determine, the more you save on gas, reagent, and lamp usage Get accurate results –– Determine 10...
Open the catalog to page 4Fast Sequential vs Conventional AA Fast Sequential mode Using Fast Sequential mode, samples are only aspirated once, with all elements being measured before the next sample is aspirated. Sample 1 Uptake Delay Sample 2 Uptake Delay Sample 3 Uptake Delay Conventional mode Conventional AA determines only one element from each sample aspiration, so samples are analyzed time and time again during a multi-element sequence. Sample 1 Uptake Delay Sample 1 Uptake Delay Sample 2 Uptake Delay Sample 2 Uptake Delay Sample 3 Uptake Delay Sample 1 Uptake Delay Sample 2 Uptake Delay Sample 3 Uptake Delay...
Open the catalog to page 5Sensitive and Accurate Furnace AA Agilent’s 240Z/280Z AA with Zeeman background correction provides the furnace performance and background correction accuracy required to measure ppb levels of toxic, heavy metals such as Pb and Cd. 240Z/280Z AA Zeeman dedicated GFAA Agilent’s 240Z/280Z AA features Zeeman background correction for correction over the full wavelength range, structured backgrounds, spectral interferences, and high background absorbances. Outstanding performance for challenging samples –– Outstanding performance at ppb levels from the Constant Temperature Zone (CTZ) furnace...
Open the catalog to page 6An Agilent Duo system – simultaneous flame and furnace operation from one PC The Duo–simultaneous flame and furnace The Agilent range of Duo systems offer simultaneous flame and furnace operation that delivers the lowest cost per analysis, making it ideal for busy laboratories. –– Double the productivity of your laboratory—an Agilent AA Duo provides true simultaneous operation of flame and graphite furnace from a central computer –– Save time with dedicated atomizers that eliminate complex setup and time consuming changeovers. Each atomizer is permanently aligned for immediate use and never...
Open the catalog to page 7Accessories to Meet Your Analysis Challenges With an extensive range of accessories to extend the capabilities of Agilent AA instruments, you can meet all your analysis challenges. Automatic dilutions, calibrations, and inline additions and spikes Agilent’s Sample Introduction Pump Systems (SIPS) improve productivity with a range of unique benefits for flame AA. –– Inline addition of ionization suppressants during analysis, eliminating manual preparation before analysis –– Eliminates tedious, manual preparation of multiple calibration standards. SIPS requires only one calibration standard...
Open the catalog to page 8Agilent AA 280FS, fitted with the GTA 120 Hydride analysis Graphite furnace The 240 AA flame with Vapor Generation Accessory (VGA 77) is well suited to cost-conscious environmental, food, and agriculture laboratories. It offers a dedicated solution for trace level determination of Hg using the regulatory approved cold vapor technique, or hydride forming elements such as As and Se using the vapor generation technique. Agilent’s integrated GTA 120 Graphite Tube Atomizer provides superior furnace performance, no matter how difficult the sample, making it ideal for applications as diverse as...
Open the catalog to page 9Software to Simplify Your Analysis User-friendly software with all instrument controls, sample results, and signal graphics accessible from one window. Simple method development Track consumables usage –– Be guided through every aspect of analysis. This includes setting up a Fast Sequential sequence or creating custom racks and layouts for use with the SPS 4 autosampler –– Save on downtime and running costs by tracking the operating lifetime of key consumables such as lamps, electrodes, and pump tubing. You can also track how many replicates or samples have been run to help anticipate...
Open the catalog to page 10Services and Supplies Maximize your productivity and data quality with genuine Agilent atomic spectroscopy supplies. Your essential resource for supplies Agilent AA supplies are manufactured to stringent specifications and rigorously tested to ensure you can optimize performance. Agilent offers an extensive range of single-element and solid cathode multi-element lamps, and high intensity UltrAA lamps for superior, cost effective performance. Why risk compromising your analytical result with anything else? For more information, see www.agilent.com/chem/specsuppliesinfo Our services let you...
Open the catalog to page 11All Agilent Technologies - Life Sciences and Chemical catalogs and technical brochures
-
Agilent 280 Series AA Systems
12 Pages
-
Inorganic Standards
40 Pages
-
InfinityLab LC Supplies
148 Pages
-
General Chromatography
164 Pages
-
Sample Preparation (2018/2019)
144 Pages
-
MS500
12 Pages
-
FLAME ATOMIC ABSORPTION SPECTROSCOPY
104 Pages
-
Agilent training
27 Pages
-
AGILENT VACUUM PRODUCTS CATALOG
536 Pages
-
Vacuum Measurement Catalog
44 Pages
-
AGILENT ION Pumps
53 Pages
-
AGILENT DIFFUSION PUMPS
35 Pages
-
AGILENT Rotary Vane Pumps
29 Pages
-
Agilent InfinityLab LC Series
16 Pages
-
3100 fractionator
8 Pages
-
4200 MP-AES
12 Pages
-
Agilent GPC/SEC Solutions
12 Pages
-
Agilent?s biomass solutions
12 Pages
-
X-ray Crystallography
12 Pages
-
Agilent ProPulse NMR System
5 Pages
-
An autosampler like no other
4 Pages
-
Agilent U1450A/U1460A
19 Pages
-
Agilent B1507A
22 Pages
-
Agilent M9703A
16 Pages
-
W1905 Radar Model Library
16 Pages
-
M8048A ISI Channels
7 Pages
-
Agilent J-BERT M8020A
27 Pages
-
Agilent N8900 Series
10 Pages
-
I/O Hardware
16 Pages
-
Advanced Design System
16 Pages
-
RF & Microwave Attenuators
4 Pages
-
E4980AL Precision LCR Meter
8 Pages
-
FieldFox Handheld Analyzers
8 Pages
-
AFM/SPM Accessories
20 Pages
-
VEE 9.32
24 Pages
-
89600 VSA Software
9 Pages
-
Command Expert
2 Pages
-
E5061B Network Analyzer
8 Pages
-
E5071C ENA Network Analyzers
18 Pages
-
N9038A MXE EMI Receiver
2 Pages
-
N9322C Basic Spectrum Analyzer
10 Pages
-
Digital Multimeters
25 Pages
-
M9361A PXI Downconverter
2 Pages
-
Power Meters and Power Sensors
34 Pages
-
E7515A UXM Wireless Test Set
2 Pages
-
Agilent Power Products
31 Pages
-
E5063A Network Analyzer
8 Pages
-
Leak Detection Catalog
41 Pages
-
Agilent 7820A GC brochure
8 Pages
-
Agilent GC-MSD and QTOF
96 Pages
-
Agilent GC-MSD 5977
39 Pages
-
Agilent Intro BERLIN
24 Pages
-
1290 Infinity Quaternary LC
24 Pages
-
1260 Infinity Bio-inert
26 Pages
Archived catalogs
-
Diffusion Pumps Catalog
37 Pages