Catalog excerpts
EXM Wireless Test Set Datasheet Solve today, evolve tomorrow Agilent EXM Benefits • Optimize multi-device testing with up to four TRX channels per EXM: each is a complete vector signal analyzer/vector signal generator (VSA/VSG) instrument • Easily test multi-format devices with standard-specific X-Series measurement applications • Maximize throughput with raw hardware speed and advanced sequencing • Increase first-pass yield with superior signal purity and measurement accuracy • Get up and running in hours, not days, with validated turnkey chipset solutions In wireless device manufacturing, meeting ever-tougher goals and tighter schedules is easier when you have access to the best resources. The Agilent Technologies EXM wireless test set scales with your production needs and is in sync with the latest cellular and WLAN chipsets. Better yet, it delivers the speed, accuracy, and port density you need to ramp up rapidly and optimize full-volume manufacturing. The EXM is designed for multi-device testing with up to four TRXs: each is a complete vector signal analyzer (VSA), vector signal generator (VSG), and four-port RFIO. It can easily test multi-format cellular and WLAN devices including the latest technologies such as: • LTE-Advanced Carrier Aggregation (CA) • 802.11n/ac Multiple Input Multiple Output (MIMO) • LTE FDD/TDD • TD-SCDMA • HSPA+, W-CDMA • 1xEV-DO, cdma2000® • GSM/EDGE/Evo • 802.11a/b/g/n/ac
Open the catalog to page 1Agilent Technologies provides the speed, performance, and results you can trust…across the wireless device lifecycle Development Design verication & conformance (RF/RRM/PCT) Ultimate scalability & port density Exceptional value for cellular verication Low-cost WiCon test Industry’s 3G benchmark Industry benchmark GPS LTE-TDD GNSS 802.11ac W-CDMA WLAN HSPA+ HSPA TD-SCDMA EDGE Evo TD-HSPA MIMO Bluetooth® 1x EVDO Speed, performance and results you can trust...Across the wireless device lifecycle
Open the catalog to page 2Product Features X-Series user interface1 Display port Each TRX has a fully integrated VSA/VSG 1. Technology-specific software. Sold seperately. 2. Included on each TRX module. 4
Open the catalog to page 4E6640A EXM Applications Cellular Application Flexibility • Consistent repeatability of standard-based X-Series measurement applications • One application license covers up to four TRX units per mainframe • SCPI-controlled PXIe OBT compatible with EXT/E6630A • HSPA+, W-CDMA • GSM/EDGE/EDGE Evo • TD-SCDMA Wireless connectivity • 802.11a/b/g/n/ac • WiMAX • Bluetooth® 1.0 to 4.0 • GNSS: GPS, Galileo, GLONASS, Beidou, SBAS, QZSS • Digital video MIMO (2x2, 3x3, 4x4) and carrier aggregation • Switched MIMO for manufacturing test • True MIMO (multi-TRX) for design validation • LTE-A CA inter- and...
Open the catalog to page 5Product Specifications Definitions and conditions Specification Specifications describe the performance parameters covered by the product warranty and are valid from 20 to 35 °C unless otherwise noted. Typical Typical describes additional product performance information that is not covered by the product warranty. It is performance beyond specifications that 95 percent of the units exhibit with a 95 percent confidence level. This data, shown in italics, does not include measurement uncertainty, and is valid only at room temperature (approximately 25 °C) after alignment within the stated...
Open the catalog to page 6Vector signal analyzer performance Performance Capture depth Frequency and time specifications Frequency range All RF ports (options are per TRX module) Option E6640A-504 380 MHz to 3.8 GHz Option E6640A-5WC 1.1 to 1.8 GHz, 2.3 to 2.6 GHz, and 4.8 to 6.0 GHz 380 MHz to 6.0 GHz Option E6640A-506 Specified frequency range (dependent on selected frequency range option) 380 to 495 MHz 695 to 920 MHz 1425 to 1485 MHz 1620 to 2030 MHz 2300 to 2700 MHz 3400 to 3800 MHz 4900 to 6000 MHz Frequency reference Accuracy, aging rate, stability Refer to Timebase Specifications CW measurement frequency...
Open the catalog to page 7Vector signal analyzer performance continued Amplitude accuracy and range specifications (continued) CW absolute amplitude accuracy RF3 I|O and RF4 I|O ports (configured to input mode in specified frequencies) Frequency range Input level ≤ –8 to –70 dBm 380 to 495 MHz < ±0.60 dB, < ±0.30 dB typical 695 to 730 MHz < ±0.60 dB, < ±0.25 dB typical > 730 to 920 MHz < ±0.50 dB, < ±0.15 dB typical 1425 to 1485 MHz < ±0.65 dB, < ±0.30 dB typical 1620 to 2030 MHz 40 MHz BW < ±0.45 dB, < ±0.20 dB typical 160 MHz BW < ±0.70 dB, < ±0.35 dB typical 2300 to 2700 MHz 40 MHz BW < ±0.55 dB, < ±0.25 dB...
Open the catalog to page 8Vector signal generator performance Performance Arb bandwidth Arb sample memory (storage capacity) Frequency specifications Frequency range All RF ports (options are per TRX module) 380 MHz to 3.8 GHz Option E6640A-504 1.1 to 1.8 GHz, 2.3 to 2.6 GHz, and 4.8 to 6 GHz Option E6640A-5WC 380 MHz to 6.0 GHz Option E6640A-506 Specified frequency range (dependent on selected frequency range option) 380 to 490 MHz 695 to 960 MHz 1100 to 1325 MHz 1425 to 2180 MHz 2300 to 2700 MHz 3400 to 3800 MHz 4900 to 6000 MHz Frequency reference Accuracy, aging rate, stability Refer to Timebase specifications...
Open the catalog to page 9Vector signal generator performance continued Amplitude accuracy and range specifications (continued) Absolute level accuracy (specified frequencies, CW) continued 3400 to 3800 MHz Level ≤ +5 to –15 dBm < ±0.60 dB, < ±0.20 dB typical Level ≤ –15 to –80 dBm < ±0.60 dB, < ±0.30 dB typical Level ≤ –80 to –110 dBm < ±1.10 dB, < ±0.55 dB typical 4900 to 6000 MHz Level ≤ +5 to –15 dBm < ±0.70 dB, < ±0.25 dB typical Level ≤ –15 to –80 dBm < ±0.75 dB, < ±0.30 dB typical Level ≤ –80 to –100 dBm < ±1.00 dB, < ±0.50 dB typical Setting resolution 0.01 dB VSWR RF3 I|O and RF4 I|O ports (configured to...
Open the catalog to page 10All Agilent Technologies - Life Sciences and Chemical catalogs and technical brochures
-
Agilent 280 Series AA Systems
12 Pages
-
Inorganic Standards
40 Pages
-
InfinityLab LC Supplies
148 Pages
-
General Chromatography
164 Pages
-
Sample Preparation (2018/2019)
144 Pages
-
MS500
12 Pages
-
FLAME ATOMIC ABSORPTION SPECTROSCOPY
104 Pages
-
Agilent training
27 Pages
-
AGILENT VACUUM PRODUCTS CATALOG
536 Pages
-
Vacuum Measurement Catalog
44 Pages
-
AGILENT ION Pumps
53 Pages
-
AGILENT DIFFUSION PUMPS
35 Pages
-
AGILENT Rotary Vane Pumps
29 Pages
-
Agilent InfinityLab LC Series
16 Pages
-
3100 fractionator
8 Pages
-
4200 MP-AES
12 Pages
-
Agilent GPC/SEC Solutions
12 Pages
-
Agilent?s biomass solutions
12 Pages
-
X-ray Crystallography
12 Pages
-
Agilent ProPulse NMR System
5 Pages
-
An autosampler like no other
4 Pages
-
Agilent U1450A/U1460A
19 Pages
-
Agilent B1507A
22 Pages
-
Agilent M9703A
16 Pages
-
W1905 Radar Model Library
16 Pages
-
M8048A ISI Channels
7 Pages
-
Agilent J-BERT M8020A
27 Pages
-
Agilent N8900 Series
10 Pages
-
I/O Hardware
16 Pages
-
Advanced Design System
16 Pages
-
RF & Microwave Attenuators
4 Pages
-
E4980AL Precision LCR Meter
8 Pages
-
FieldFox Handheld Analyzers
8 Pages
-
AFM/SPM Accessories
20 Pages
-
VEE 9.32
24 Pages
-
89600 VSA Software
9 Pages
-
Command Expert
2 Pages
-
E5061B Network Analyzer
8 Pages
-
E5071C ENA Network Analyzers
18 Pages
-
N9038A MXE EMI Receiver
2 Pages
-
N9322C Basic Spectrum Analyzer
10 Pages
-
Digital Multimeters
25 Pages
-
M9361A PXI Downconverter
2 Pages
-
Power Meters and Power Sensors
34 Pages
-
E7515A UXM Wireless Test Set
2 Pages
-
Agilent Power Products
31 Pages
-
E5063A Network Analyzer
8 Pages
-
Leak Detection Catalog
41 Pages
-
Agilent 7820A GC brochure
8 Pages
-
Agilent GC-MSD and QTOF
96 Pages
-
Agilent GC-MSD 5977
39 Pages
-
Agilent Intro BERLIN
24 Pages
-
1290 Infinity Quaternary LC
24 Pages
-
1260 Infinity Bio-inert
26 Pages
Archived catalogs
-
Diffusion Pumps Catalog
37 Pages