Agilent AssayMAP Cartridges Automated Sample Preparation Data Sheet • Perform quantitation and sample preparation in the same workflow Agilent AssayMAP is a quantitative, high-throughput sample preparation technology which uses disposable chromatography cartridges on the Bravo Platform for AssayMAP. AssayMAP technology relies on a modified 96-channel, microplatecompatible liquid handler equipped with precision flow syringes that connect to the chromatography cartridges through a special probe. The AssayMAP Bravo head provides precise, positive-displacement flow control through the cartridges in either direction to well under 1 µL/min. The cartridges incorporate a 5 µL packed bed that can accommodate virtually any polymer, silica, or gel-based resin with particle diameters from 15 to 100 µm. Included are the specifications for four prepacked AssayMAP cartridges. • Reduce errors and increase walkaway time with reliable, automated processess • Increase throughput using existing chemistry or customized workflows
Open the catalog to page 1AssayMAP Cartridge Release Criteria Each batch of resin slurry that serves as the packing material for multiple cartridge racks is packed into cartridges and representative cartridges per batch are functionally tested for dynamic binding. Every AssayMAP cartridge is pressure/flow tested and visually inspected. The flow test measures the pressure drop across the cartridge at a specified flow rate. Visual inspection verifies correct assembly and complete filling of the bed volume. AssayMAP Cartridge Reuse Performance is guaranteed when cartridges are used on the same day they are equilibrated....
Open the catalog to page 2Cartridge Part number Cartridge code Contents Resin Pore size Particle size range Bed volume Chemistry Bead Ligand Capacity Dynamic binding capacity Saturation binding capacity Stability pH Range Reversed Phase G5496-60033 RP-S 1 rack/96 cartridges Synthetic polymer Streptavidin, recombinant Underivatized polystyrene-divinylbenzene none Biotinylated IgG: ≥ 90 µg (≥ 600 pmol) Biotinylated BSA: ≥ 50 µg (≥ 750 pmol) Biotinylated FITC: ND Biotinylated IgG: ~100 µg (~700 pmol) Biotinylated BSA: ~60 µg (~900 pmol) Biotinylated FITC: ~3.5 µg (~5000 pmol) Quantitative binding of ≥ 450 µg human insulin...
Open the catalog to page 3Learn More www.agilent.com/lifesciences/AssayMAP Find a local Agilent customer center www.agilent.com/chem/contactus USA and Canada 1-800-227-9770 [email protected] Europe [email protected] Asia Pacific [email protected] This information is subject to change www.agilent.com/chem/xxxxx without notice. For Research Use Only. Not for use in diagnostic procedures. © Agilent Technologies, Inc., 2011 Published in Country, Month xx, 2011 © Agilent Technologies, Inc., 2013 Publication Number xxxx-xxxxEN
Open the catalog to page 412 Pages
40 Pages
148 Pages
164 Pages
144 Pages
12 Pages
104 Pages
27 Pages
536 Pages
44 Pages
53 Pages
35 Pages
29 Pages
16 Pages
8 Pages
12 Pages
12 Pages
12 Pages
12 Pages
5 Pages
4 Pages
19 Pages
22 Pages
16 Pages
16 Pages
7 Pages
27 Pages
10 Pages
16 Pages
16 Pages
4 Pages
8 Pages
8 Pages
20 Pages
24 Pages
9 Pages
2 Pages
8 Pages
18 Pages
2 Pages
10 Pages
25 Pages
2 Pages
34 Pages
2 Pages
31 Pages
8 Pages
41 Pages
8 Pages
96 Pages
39 Pages
24 Pages
24 Pages
26 Pages
37 Pages