Catalog excerpts
DUAL VIEW ICP-OES
Open the catalog to page 1THE FASTEST ICP-OES... EVER. The Agilent 5100 Synchronous Vertical Dual View (SVDV) ICP-OES revolutionizes ICP-OES analysis. With its unique Dichroic Spectral Combiner (DSC) technology, you can now run axial and radial view analysis at the same time. Save time and money Simplify your analysis • the fastest ICP-OES analysis, using less gas. Run • Take the guess work out of method development with intuitive ICP Expert software and DSC technology. • Measure all wavelengths in one measurement, for higher precision without delays. • Ensure fast startup with minimal training using...
Open the catalog to page 255% FASTER. 50% LESS ARGON. How does Synchronous Vertical Dual View work? The 5100 SVDV ICP-OES needs only a single measurement per sample. The Dichroic Spectral Combiner allows both the axial and radial views of the plasma to be captured in one reading. This delivers accurate results in the quickest possible time1. Radial light Axial light Dramatically reduce your argon consumption1 The 5100 ICP-OES has the lowest argon consumption per sample of any ICP-OES instrument. Vertical torch and plasma DID YOU KNOW? Dichroic Spectral Combiner (DSC) Conventional dual view ICP-OES systems require...
Open the catalog to page 3FAST, ACCURATE RESULTS, EVEN FOR YOUR TOUGHEST SAMPLES. MINIMIZE INTERFERENCES The CCI removes the cool plasma tail from the axial optical path. This minimizes self-absorption and recombination interferences to provide a wide linear dynamic range and low background for the most accurate results. ACHIEVE LONG TERM ANALYTICAL STABILITY A solid state RF system delivers a reliable, robust and maintenance-free plasma for even the toughest samples. CONQUER EVEN THE MOST DIFFICULT SAMPLES A vertical torch allows you to measure the most challenging samples – from high matrix to volatile organic...
Open the catalog to page 4DELIVER FAST, ACCURATE RESULTS IN A SINGLE MEASUREMENT The DSC enables the light from both the radial and the axial views of the plasma to be measured at the same time. Only one reading is needed per sample. CHOOSE HIGH THROUGHPUT AND DYNAMIC RANGE The VistaChip II detector is a high speed, continuous wavelength coverage CCD detector with anti-blooming protection on every pixel. It is a zero gas consumption design and enables fast warm-up, high throughput, high sensitivity, and the largest dynamic range. SAVE BENCH SPACE WITH COMPACT DESIGN The world’s smallest ICP-OES saves valuable bench...
Open the catalog to page 5AGILENT5100 ICP-OES AGILENT 5100 ICP-OES GET THE RIGHT RESULTS THE FIRST TIME, EVERY TIME. Simplify your analysis A Off peak background correction B Fitted background correction (FBC) The Agilent ICP Expert software has a familiar worksheet interface, easy method development and software applets that include pre-set method templates, saving you time. C Analytical wavelength D Error without using FBC Take the guess work out of method development The 5100 ICP-OES with DSC eliminates the need to select the correct plasma mode in which to run each element. Just choose your elements and...
Open the catalog to page 6PRODUCTIVITY & PERFORMANCE ENHANCEMENTS. Plug-and-play torch The simple and effective torch loader mechanism automatically aligns the torch and connects gases for fast start up and reproducible performance. Once the torch is loaded, no further alignment or adjustment is required. SVS 2+ Switching Valve System Reduces cost per analysis and more than doubles the productivity of your 5100 ICP-OES by reducing sample uptake, stabilization times, and rinse delays. Torch installation in three easy steps Open the torch loader Automates and simplifies analysis, with extended sample capacity via rack...
Open the catalog to page 7For more information Learn more www.agilent.com/chem/5100icpoes U.S. and Canada 1-800-227-9770 agilent_inquiries@agilent.com Europe info_agilent@agilent.com Asia Pacific inquiry_lsca@agilent.com In other countries, please call your local Agilent Representative or Agilent Authorized Distributor — visit www.agilent.com/chem/contactus Services let you focus on what you do best Whether you need support for a single instrument or multiple labs, Agilent can help you solve problems quickly, increase uptime, and maximize the productivity of your team with: • Familiarization disk including over 20...
Open the catalog to page 8All Agilent Technologies - Life Sciences and Chemical catalogs and technical brochures
-
Agilent 280 Series AA Systems
12 Pages
-
Inorganic Standards
40 Pages
-
InfinityLab LC Supplies
148 Pages
-
General Chromatography
164 Pages
-
Sample Preparation (2018/2019)
144 Pages
-
MS500
12 Pages
-
FLAME ATOMIC ABSORPTION SPECTROSCOPY
104 Pages
-
Agilent training
27 Pages
-
AGILENT VACUUM PRODUCTS CATALOG
536 Pages
-
Vacuum Measurement Catalog
44 Pages
-
AGILENT ION Pumps
53 Pages
-
AGILENT DIFFUSION PUMPS
35 Pages
-
AGILENT Rotary Vane Pumps
29 Pages
-
Agilent InfinityLab LC Series
16 Pages
-
3100 fractionator
8 Pages
-
4200 MP-AES
12 Pages
-
Agilent GPC/SEC Solutions
12 Pages
-
Agilent?s biomass solutions
12 Pages
-
X-ray Crystallography
12 Pages
-
Agilent ProPulse NMR System
5 Pages
-
An autosampler like no other
4 Pages
-
Agilent U1450A/U1460A
19 Pages
-
Agilent B1507A
22 Pages
-
Agilent M9703A
16 Pages
-
W1905 Radar Model Library
16 Pages
-
M8048A ISI Channels
7 Pages
-
Agilent J-BERT M8020A
27 Pages
-
Agilent N8900 Series
10 Pages
-
I/O Hardware
16 Pages
-
Advanced Design System
16 Pages
-
RF & Microwave Attenuators
4 Pages
-
E4980AL Precision LCR Meter
8 Pages
-
FieldFox Handheld Analyzers
8 Pages
-
AFM/SPM Accessories
20 Pages
-
VEE 9.32
24 Pages
-
89600 VSA Software
9 Pages
-
Command Expert
2 Pages
-
E5061B Network Analyzer
8 Pages
-
E5071C ENA Network Analyzers
18 Pages
-
N9038A MXE EMI Receiver
2 Pages
-
N9322C Basic Spectrum Analyzer
10 Pages
-
Digital Multimeters
25 Pages
-
M9361A PXI Downconverter
2 Pages
-
Power Meters and Power Sensors
34 Pages
-
E7515A UXM Wireless Test Set
2 Pages
-
Agilent Power Products
31 Pages
-
E5063A Network Analyzer
8 Pages
-
Leak Detection Catalog
41 Pages
-
Agilent 7820A GC brochure
8 Pages
-
Agilent GC-MSD and QTOF
96 Pages
-
Agilent GC-MSD 5977
39 Pages
-
Agilent Intro BERLIN
24 Pages
-
1290 Infinity Quaternary LC
24 Pages
-
1260 Infinity Bio-inert
26 Pages
Archived catalogs
-
Diffusion Pumps Catalog
37 Pages