Catalog excerpts
Agilent 4300 Handheld FTIR Spectrometer AT-SITE. IMMEDIATE RESULTS. TRUE NON-DESTRUCTIVE ANALYSIS.
Open the catalog to page 1BRING THE POWER OF FTIR SPECTROSCOPY OUT OF THE LAB… AND TO THE SAMPLE From improving composite bonding… to performance-testing of coatings… to verifying polymer identity and authenticity… to measuring metal surface contamination… success depends upon generating actionable, on-the-spot results. Perform accurate, non-destructive material testing with the Agilent 4300 Handheld FTIR The versatile, ergonomic 4300 Handheld FTIR is ideally suited to at-site, mid-IR measurement of objects constructed from high-value materials. Its optimized design lets you quickly scan large surfaces or areas, and...
Open the catalog to page 2GENERATE ACTIONABLE DATA FOR THESE AND OTHER APPLICATIONS Aerospace, automotive, paints, and coatings • omposites: Assess thermal, chemical, and C environmental damage; test for curing; verify composition; and analyze surface plasma treatment • olymers: Verify composition and authenticity; detect P contaminants; and test for curing • ubber and elastomers: Measure the composition of R carbon-filled materials, such as tires • oatings: Confirm composition, thickness and C uniformity; measure degradation; and ensure proper surface preparation Non-destructive testing, right on the spot The 4300...
Open the catalog to page 3ENHANCED MATERIAL ANALYSIS FROM THE PEOPLE WHO DEVELOPED THE ORIGINAL HANDHELD FTIR More reproducible results: At 5 pounds (2.2 Kg), the 4300 is comfortable to hold and use. It also has a perfect weight distribution with its batteries located in the base to balance the optical head. Optimized ergonomics means better quality results, especially for analyses that require longer measurement times, numerous measurement points, or are on objects that are physically constrained. Superior performance: A proven interferometer design, ultra-short internal optical path, optically matched sample...
Open the catalog to page 4Longer periods of continuous operation: The lithium ion batteries that power the 4300 can easily be swapped while the system is running. Flexibility for every method: Interchangeable, snap-on interfaces require no alignment, and are custom engineered to match optics and electronics. These interfaces are RFID equipped to ensure they are correctly matched to the specific method required for an analysis. You can also choose between two detectors: a DGTS detector for routine analysis, and a thermoelectrically cooled MCT detector for applications that require high performance and speed. C ontrol...
Open the catalog to page 5MEET THE NEXT GENERATION OF FTIR MOBILITY Touch-screen user interface runs the MicroLab Mobile software. Flexibility for every method. Interchangeable, snap-on interfaces require no alignment, are custom engineered to match system optics, and are equipped with RFID sensors to ensure the correct match between sample interface and analytical method. Easy trigger initiates method commands. 4-hour Li ion batteries: “hot” swappable for extended system use Reliable field measurements when and where you need them. Visit agilent.com/chem/4300HandheldFTIR 6
Open the catalog to page 6Optically matched sample interfaces afford the highestquality data for the broadest range of samples Advanced optomechanical and low-noise electronics with no alignment needed DIAMOND ATR Just right for solids, liquids, pastes, and gels, this interface consists of a diamond ATR sensor, which is impervious to corrosion and scratching. After samples come into contact with the diamond window, the top 2-3 surface microns are analyzed. DIFFUSE REFLECTANCE Diffuse reflectance is best for samples that reflect little light, such as artwork, soils, rocks and minerals, composites, rough plastics,...
Open the catalog to page 7MEASURE SMARTER, MEASURE FASTER FOR YOUR KEY APPLICATIONS The Agilent 4300 Handheld FTIR non-destructively handles field measurements across diverse industries Composites The 4300 Handheld FTIR is proven to deliver outstanding results in applications such as: • etecting damage caused by excess exposure to heat D • Mapping thermal damage on surfaces • uiding sanding, scarfing, and patching repairs G • easuring oxidative damage from UV light and other M environmental factors • onfirming the effectiveness of plasma treatment in preparing C composite surfaces for bonding • etecting hydrocarbon...
Open the catalog to page 8From paints… to polymers… to adhesives… the 4300 Handheld FTIR lets you confidently: • onfirm that underlying metal surfaces are clean and C contaminant free • rack the cleaning of contaminants from inorganic and T organic surfaces • nsure that the correct coating has been applied to the E finished product • est whether primers and coatings are properly cured T • easure thickness and uniformity on metal surfaces M • valuate monolayer coatings for coverage and uniformity E • Monitor paint aging and weathering • dentify lacquers, paints, and pigments used in art conservation I and restoration...
Open the catalog to page 9AGILENT MICROLAB MOBILE SOFTWARE For any application… Agilent MicroLab Mobile software is the perfect complement for the 4300 Handheld FTIR Powerful analytical capability, combined with an intuitive user interface, allows users of all levels to obtain great data in the field. • Pictoral interface simplifies sample measurement • FID-enabled to optimize system acquisition parameters, and R confirm that your sample interface and selected method are a match • eal-time analysis mode and rapid scan rate make it easy to analyze R the surface of an object, determine areas for more in-depth...
Open the catalog to page 10Visual, intuitive user enable rapid system The highly acclaimed Agilent MicroLab Mobile software enables users of varied experience to get great results from the 4300 with a minimal training. The software guides the user through the measurement, and the RFID-equipped sample interfaces ensure that the method and measurement parameters are correctly matched. These innovations mean the 4300 will rapidly become an important part of your company's workflow. METHOD: COMPOSITE Select Method From the home screen you can quickly launch analysis, choose a method, and create a new reference method....
Open the catalog to page 11All Agilent Technologies - Life Sciences and Chemical catalogs and technical brochures
-
Agilent 280 Series AA Systems
12 Pages
-
FLAME ATOMIC ABSORPTION SPECTROSCOPY
104 Pages
-
Inorganic Standards
40 Pages
-
InfinityLab LC Supplies
148 Pages
-
General Chromatography
164 Pages
-
Sample Preparation (2018/2019)
144 Pages
-
MS500
12 Pages
-
FLAME ATOMIC ABSORPTION SPECTROSCOPY
104 Pages
-
Agilent training
27 Pages
-
AGILENT VACUUM PRODUCTS CATALOG
536 Pages
-
Vacuum Measurement Catalog
44 Pages
-
AGILENT ION Pumps
53 Pages
-
AGILENT DIFFUSION PUMPS
35 Pages
-
AGILENT Rotary Vane Pumps
29 Pages
-
Agilent InfinityLab LC Series
16 Pages
-
3100 fractionator
8 Pages
-
4200 MP-AES
12 Pages
-
Agilent GPC/SEC Solutions
12 Pages
-
Agilent?s biomass solutions
12 Pages
-
X-ray Crystallography
12 Pages
-
Agilent ProPulse NMR System
5 Pages
-
An autosampler like no other
4 Pages
-
Agilent U1450A/U1460A
19 Pages
-
Agilent B1507A
22 Pages
-
Agilent M9703A
16 Pages
-
W1905 Radar Model Library
16 Pages
-
M8048A ISI Channels
7 Pages
-
Agilent J-BERT M8020A
27 Pages
-
Agilent N8900 Series
10 Pages
-
I/O Hardware
16 Pages
-
Advanced Design System
16 Pages
-
RF & Microwave Attenuators
4 Pages
-
E4980AL Precision LCR Meter
8 Pages
-
FieldFox Handheld Analyzers
8 Pages
-
AFM/SPM Accessories
20 Pages
-
VEE 9.32
24 Pages
-
89600 VSA Software
9 Pages
-
Command Expert
2 Pages
-
E5061B Network Analyzer
8 Pages
-
E5071C ENA Network Analyzers
18 Pages
-
N9038A MXE EMI Receiver
2 Pages
-
N9322C Basic Spectrum Analyzer
10 Pages
-
Digital Multimeters
25 Pages
-
M9361A PXI Downconverter
2 Pages
-
Power Meters and Power Sensors
34 Pages
-
E7515A UXM Wireless Test Set
2 Pages
-
Agilent Power Products
31 Pages
-
E5063A Network Analyzer
8 Pages
-
Leak Detection Catalog
41 Pages
-
Agilent 7820A GC brochure
8 Pages
-
Agilent GC-MSD and QTOF
96 Pages
-
Agilent GC-MSD 5977
39 Pages
-
Agilent Intro BERLIN
24 Pages
-
1290 Infinity Quaternary LC
24 Pages
-
1260 Infinity Bio-inert
26 Pages
Archived catalogs
-
Diffusion Pumps Catalog
37 Pages