Catalog excerpts
Agilent Atomic Absorption Spectrometers Agilent 280 Series AA Systems
Open the catalog to page 1Highest Performance For Your Toughest Analytical Challenges The Agilent 280 AA range is productive, user-friendly, and exceptionally reliable. With a high specification optical system the instruments deliver the high performance that analysts require, while being equally at home in routine laboratories where reliability and simple operation are vital. A family of atomic absorption instruments – The 280 AA series feature a high specification optical system, with a 1800 lines/mm grating and a 330 mm focal length monochromator for enhanced resolution. Combined with a wide range photomultiplier...
Open the catalog to page 2For Your Application Agilent is committed to providing instrumentation for your application. We have the technology, platforms, and expert guidance you need to be successful. Environmental Determination of Mg, Ca, and K in brines (SIPS accessory provides automated calibration and online sample dilution) Major elements Ca, Cu, Fe, Mg, Na and Zn in food, beverage, and agricultural samples Na and K in FAME (fatty acid methyl esters) Cu in traditional Chinese medicines Au, Ag, and Pt group elements in ore grade material Analysis of Cr in soils and solid wastes Vapor Generation AA 280FS AA + VGA...
Open the catalog to page 3Fast Sequential Flame AA Achieve the productivity and speed of sequential ICP with Agilent’s Proven and Reliable Fast Sequential (FS) AA systems. Fast Sequential mode will: Boost productivity and slash running costs – Determine the concentration of all elements from a single aspiration of each sample – Halve your analysis time by reducing sample analysis delays – Reduce sample consumption—with less delay throughout analysis and less sample waste – Save labor and reduce running costs—the more elements you determine, the more you save on gas, reagents, and lamps – Further analysis time...
Open the catalog to page 4Fast Sequential vs Conventional AA Fast Sequential mode Using Fast Sequential mode, samples are only aspirated once, with all elements being measured before the next sample is aspirated. Sample 1 Uptake Delay Sample 2 Uptake Delay Sample 3 Uptake Delay Conventional mode Conventional AA determines only one element from each sample aspiration, so samples are analyzed time and time again during a multi-element sequence. Sample 1 Uptake Delay Sample 1 Uptake Delay Sample 2 Uptake Delay Sample 1 Uptake Delay Sample 2 Uptake Delay Sample 3 Uptake Delay Sample 2 Uptake Delay Sample 3 Uptake Delay...
Open the catalog to page 5Sensitive and Accurate Furnace AA The Agilent 280Z AA with Zeeman background correction provides the furnace performance and background correction accuracy required to measure ppb levels of toxic, heavy metals such as Pb and Cd. 280Z AA Zeeman dedicated GFAA Environmental agencies (such as the US EPA) accept Zeeman background correction as the most effective background correction technique for regulated environmental analyses. The Agilent 280Z AA features powerful transverse Zeeman background correction over the full wavelength range for structured backgrounds, spectral interferences, and...
Open the catalog to page 6Automate furnace AA method development Simple setup and operation Method development for the Agilent 280Z furnace AA is automated with the surface response methodology (SRM) wizard. – The PSD120 furnace autosampler (with capacity for up to 130 solutions), automatically prepares and delivers calibration standards from a single bulk standard. The autosampler also provides calibration through standard addition. Good method development is critical to ensure the best performance in GFAAS. The unique Agilent SRM Wizard finds the optimum relationship between furnace ash temperature, atomization...
Open the catalog to page 7The Duo–simultaneous flame and furnace The Agilent range of Duo systems offer simultaneous flame and furnace operation that delivers the lowest cost per analysis, making it ideal for busy laboratories. – Double the productivity of your laboratory—an Agilent AA Duo provides true simultaneous operation of flame and graphite furnace from a central computer – Save time with dedicated atomizers that eliminate complex setup and time consuming changeovers. Each atomizer is permanently aligned for immediate use and never needs re-alignment – Analyze any sample, with the widest linear dynamic range...
Open the catalog to page 8Software to Simplify Your Analysis User-friendly software with all instrument controls, sample results, and signal graphics accessible from one window. Simple method development – Be guided through every aspect of analysis. Guidance includes setting up a Fast Sequential sequence or creating custom racks and layouts for use with the SPS 4 autosampler – Save on downtime and running costs by tracking the operating lifetime of key consumables such as lamps, electrodes, and pump tubing. You can also track how many replicates or samples have been run to help anticipate consumable replacement –...
Open the catalog to page 9Accessories to Meet Your Analysis Challenges With an extensive range of accessories to extend the capabilities of Agilent AA instruments, you can meet all your analysis challenges. Automatic dilutions, calibrations, and inline additions and spikes Fast and flexible autosampler The Sample Introduction Pump System (SIPS) improves productivity with a range of unique benefits for flame AA. Able to minimize re-runs by automatically preparing calibration standards and performing over-range dilutions up to 200x with less than 2% error. Automate your analysis with the Agilent SPS 4 high-performance...
Open the catalog to page 10Tune your flame AA performance The Agilent Mark 7 atomization system is supplied as standard with the 280 FS AA instruments. It can: – Achieve high sensitivity—typically > 0.9 Abs. from 5 mg/L Cu – Optimize precision—typically < 0.5% RSD from ten 5 second integrations – Reduce interferences for complex samples with removable twin headed mixing paddles – Minimize burner blockage with a contoured burner design – Corrosion resistant components provide increased durability making it ideal for high acid matrices Services and Supplies Maximize your productivity and data quality with genuine...
Open the catalog to page 11All Agilent Technologies - Life Sciences and Chemical catalogs and technical brochures
-
Inorganic Standards
40 Pages
-
InfinityLab LC Supplies
148 Pages
-
General Chromatography
164 Pages
-
Sample Preparation (2018/2019)
144 Pages
-
MS500
12 Pages
-
FLAME ATOMIC ABSORPTION SPECTROSCOPY
104 Pages
-
Agilent training
27 Pages
-
AGILENT VACUUM PRODUCTS CATALOG
536 Pages
-
Vacuum Measurement Catalog
44 Pages
-
AGILENT ION Pumps
53 Pages
-
AGILENT DIFFUSION PUMPS
35 Pages
-
AGILENT Rotary Vane Pumps
29 Pages
-
Agilent InfinityLab LC Series
16 Pages
-
3100 fractionator
8 Pages
-
4200 MP-AES
12 Pages
-
Agilent GPC/SEC Solutions
12 Pages
-
Agilent?s biomass solutions
12 Pages
-
X-ray Crystallography
12 Pages
-
Agilent ProPulse NMR System
5 Pages
-
An autosampler like no other
4 Pages
-
Agilent U1450A/U1460A
19 Pages
-
Agilent B1507A
22 Pages
-
Agilent M9703A
16 Pages
-
W1905 Radar Model Library
16 Pages
-
M8048A ISI Channels
7 Pages
-
Agilent J-BERT M8020A
27 Pages
-
Agilent N8900 Series
10 Pages
-
I/O Hardware
16 Pages
-
Advanced Design System
16 Pages
-
RF & Microwave Attenuators
4 Pages
-
E4980AL Precision LCR Meter
8 Pages
-
FieldFox Handheld Analyzers
8 Pages
-
AFM/SPM Accessories
20 Pages
-
VEE 9.32
24 Pages
-
89600 VSA Software
9 Pages
-
Command Expert
2 Pages
-
E5061B Network Analyzer
8 Pages
-
E5071C ENA Network Analyzers
18 Pages
-
N9038A MXE EMI Receiver
2 Pages
-
N9322C Basic Spectrum Analyzer
10 Pages
-
Digital Multimeters
25 Pages
-
M9361A PXI Downconverter
2 Pages
-
Power Meters and Power Sensors
34 Pages
-
E7515A UXM Wireless Test Set
2 Pages
-
Agilent Power Products
31 Pages
-
E5063A Network Analyzer
8 Pages
-
Leak Detection Catalog
41 Pages
-
Agilent 7820A GC brochure
8 Pages
-
Agilent GC-MSD and QTOF
96 Pages
-
Agilent GC-MSD 5977
39 Pages
-
Agilent Intro BERLIN
24 Pages
-
1290 Infinity Quaternary LC
24 Pages
-
1260 Infinity Bio-inert
26 Pages
Archived catalogs
-
Diffusion Pumps Catalog
37 Pages