Catalog excerpts
Agilent 200 Series AA Systems AGILENT ATOMIC ABSORPTION
Open the catalog to page 1PRODUCTIVE, PRECISE, RELIABLE. Agilent’s AA range is productive, user-friendly and exceptionally reliable. The instruments deliver the high performance that analysts require, while being equally at home in routine laboratories where reliability and simple operation are vital. A family of Atomic Absorption solutions • Double your productivity with Agilent’s AA Duo, the world’s only AA systems that provide true simultaneous operation of flame and graphite furnace without changeover delays. • Agilent’s 240 AA combines flexibility with reliable hardware, providing budget-sensitive users with a...
Open the catalog to page 2FOR YOUR APPLICATION Agilent is committed to providing solutions for your application. We have the technology, platforms, and expert guidance you need to be successful. INDUSTRIAL CHEMICAL & FOOD & PETROCHEMICAL ENVIRONMENTAL AGRICULTURE Pb & Cd in consumer goods e.g., toys, jewelry Ca, Cr, Cu, Fe, K, Mg & Na in plating solutions Na & K in FAME (fatty acid methyl esters) Pb & Mn in unleaded gasoline Heavy metals in soils Chemical analysis of cement Zn & Sb in paper Ca, Cr, Cu, Fe, K, Mg & Na in plating solutions Wear metals in used oils Additives (e.g. Ba, Ca, Mn & Zn) in fresh lubricating...
Open the catalog to page 3AGILENTAA SPECTROMETERS AGILENT 5100 ICP-OES THE FASTEST FLAME AA. Achieve the productivity and speed of sequential ICP with Agilent’s Fast Sequential (FS) AA systems. Agilent’s FS systems deliver productivity and profitability for your lab. 240FS/280FS AA How does Fast Sequential AA work? By measuring all elements in a single analysis of each sample, Agilent’s Fast Sequential AA provides complete results for each sample in minutes. In addition to saving you valuable time and doubling sample throughput, the 240FS/280FS AA also reduce running costs. 1. etermination time is optimized as the...
Open the catalog to page 4INDUSTRIAL & PETROCHEMICAL Whether you are analyzing raw materials and components, or conducting product testing, robust reliable solutions are essential to your success. Agilent's AA range is ideal for mid-sized laboratories handling a wide variety of sample types such as feed or reagents, intermediate and final products, samples from cooling systems, waste products and final residues or effluents. Flexible sample handling Automate your analyses with Agilent's SPS 3 Sample Preparation System and speed up flame AA even further. Using the SPS 3, you can create a convenient sample preparation...
Open the catalog to page 5AGILENTAA SPECTROMETERS AGILENT 5100 ICP-OES THE MOST SENSITIVE FURNACE AA. Graphite furnace AA is the preferred technique for ppb level determinations of toxic, heavy metals such as Pb and Cd. The 240Z/280Z AA with Zeeman background correction provides superior furnace performance and accurate background correction to eliminate interferences. 240Z/280Z AA Zeeman dedicated GFAA The 240Z/280Z AA features Zeeman background correction for correction over the full wavelength range, structured background, spectral interferences and high background absorbances. The 240FS/240Z AA Duo system offers...
Open the catalog to page 6The world’s best Zeeman AA PRECISE SOLUTIONS FOR ENVIRONMENTAL Zeeman background correction has been widely accepted by international regulatory agencies (such as the US EPA) as the most effective background correction technique for regulated environmental analyses. In a field that demands accuracy, productivity and regulatory compliance, your challenges have never been greater. Today, environmental analysis must be done more reliably, more efficiently, and with even higher quality results. Agilent Zeeman systems feature the transverse AC modulated Zeeman configuration with the field...
Open the catalog to page 7AGILENTAA SPECTROMETERS AGILENT 5100 ICP-OES MEET YOUR ANALYSIS CHALLENGES. With an extensive range of accessories to extend the capabilities of Agilent AA instruments, you can meet all your analysis challenges. SIPS 20 Eliminate manual dilution errors SIPS provides better accuracy and reproducibility than manual dilution Agilent’s Sample Introduction Pump Systems (SIPS) improve productivity with a range of unique benefits for flame AA. SIPS dilution performance Actual Conc. mg/L • Performs online spiking of samples for spike recovery studies • Enhances accuracy and precision — with < 2%...
Open the catalog to page 8RELIABLE SOLUTIONS FOR FOOD & AGRICULTURE Agilent’s integrated GTA 120 Graphite Tube Atomizer provides superior furnace performance, no matter how difficult the sample, making them ideal for applications as diverse as chemical, petrochemical, food and agriculture. You are committed to providing food, beverages and agricultural products of consistent quality and uncompromising safety. Agilent provides products and services to help you deliver on that promise. • Extremely fast atomization even with difficult sample matrices • Best signal-to-noise, due to the long atomization cell. This...
Open the catalog to page 9AGILENTAA SPECTROMETERS AGILENT 5100 ICP-OES BE SURE OF YOUR ANSWERS. With the world’s fastest flame AA, the world’s most sensitive furnace AA, straightforward software and unmatched instrument ruggedness and reliability, you can be sure that an Agilent AA will give you answers you can trust. Tune your flame AA performance Application flexibility The Mark 7 atomization system provides the capability to routinely handle high matrix samples, and the flexibility to achieve high sensitivity. Achieve precise results quickly and handle complex matrices with Agilent’s flexible and convenient Mark...
Open the catalog to page 10SOFTWARE TO SIMPLIFY YOUR ANALYSIS. User friendly software with all instrument controls, sample results and signal graphics accessible from one window. • guided through every aspect of analysis, such as setting up Be a Fast Sequential sequence or creating custom racks and layouts for use with the SPS 3. • Save on downtime and running costs by tracking the operating lifetime of key consumables such as lamps, electrodes and pump tubing. For GLP compliance, you can also track how many replicates or samples have been run. • Eliminate method development and automate furnace optimization with the...
Open the catalog to page 11All Agilent Technologies - Life Sciences and Chemical catalogs and technical brochures
-
Agilent 280 Series AA Systems
12 Pages
-
FLAME ATOMIC ABSORPTION SPECTROSCOPY
104 Pages
-
Inorganic Standards
40 Pages
-
InfinityLab LC Supplies
148 Pages
-
General Chromatography
164 Pages
-
Sample Preparation (2018/2019)
144 Pages
-
MS500
12 Pages
-
FLAME ATOMIC ABSORPTION SPECTROSCOPY
104 Pages
-
Agilent training
27 Pages
-
AGILENT VACUUM PRODUCTS CATALOG
536 Pages
-
Vacuum Measurement Catalog
44 Pages
-
AGILENT ION Pumps
53 Pages
-
AGILENT DIFFUSION PUMPS
35 Pages
-
AGILENT Rotary Vane Pumps
29 Pages
-
Agilent InfinityLab LC Series
16 Pages
-
3100 fractionator
8 Pages
-
4200 MP-AES
12 Pages
-
Agilent GPC/SEC Solutions
12 Pages
-
Agilent?s biomass solutions
12 Pages
-
X-ray Crystallography
12 Pages
-
Agilent ProPulse NMR System
5 Pages
-
An autosampler like no other
4 Pages
-
Agilent U1450A/U1460A
19 Pages
-
Agilent B1507A
22 Pages
-
Agilent M9703A
16 Pages
-
W1905 Radar Model Library
16 Pages
-
M8048A ISI Channels
7 Pages
-
Agilent J-BERT M8020A
27 Pages
-
Agilent N8900 Series
10 Pages
-
I/O Hardware
16 Pages
-
Advanced Design System
16 Pages
-
RF & Microwave Attenuators
4 Pages
-
E4980AL Precision LCR Meter
8 Pages
-
FieldFox Handheld Analyzers
8 Pages
-
AFM/SPM Accessories
20 Pages
-
VEE 9.32
24 Pages
-
89600 VSA Software
9 Pages
-
Command Expert
2 Pages
-
E5061B Network Analyzer
8 Pages
-
E5071C ENA Network Analyzers
18 Pages
-
N9038A MXE EMI Receiver
2 Pages
-
N9322C Basic Spectrum Analyzer
10 Pages
-
Digital Multimeters
25 Pages
-
M9361A PXI Downconverter
2 Pages
-
Power Meters and Power Sensors
34 Pages
-
E7515A UXM Wireless Test Set
2 Pages
-
Agilent Power Products
31 Pages
-
E5063A Network Analyzer
8 Pages
-
Leak Detection Catalog
41 Pages
-
Agilent 7820A GC brochure
8 Pages
-
Agilent GC-MSD and QTOF
96 Pages
-
Agilent GC-MSD 5977
39 Pages
-
Agilent Intro BERLIN
24 Pages
-
1290 Infinity Quaternary LC
24 Pages
-
1260 Infinity Bio-inert
26 Pages
Archived catalogs
-
Diffusion Pumps Catalog
37 Pages