Agilent 1290 Infinity Thermostat User Manual Agilent Technologies
Open the catalog to page 1No part of this manual may be reproduced in any form or by any means (including elec- tronic storage and retrieval or translation into a foreign language) without prior agree- ment and written consent from Agilent Technologies, Inc. as governed by United States and international copyright laws. Manual Part Number Agilent Technologies This product may be used as a com- ponent of an in vitro diagnostic sys- tem if the system is registered with plies with the relevant regulations. Otherwise, it is intended only for gen- The material contained in this docu- ject to being changed, without...
Open the catalog to page 22 Site Requirements and Specifications 11 Optimizing the Stack Configuration 19 Transporting the Thermostatted Autosampler or Fraction Collector Agilent Lab Advisor Software 34 Overview of the Thermostat's Indicators and Test Functions 35 What Are Error Messages 40 General Error Messages 41 Thermostat Error Messages 48 1290 Infinity Thermostat User Manual
Open the catalog to page 3Exchanging the Power Supply Fuses 58 Main Assemblies (External Parts) 62 HPLC System Tool Kit 65 External Contact Cable 79 Early Maintenance Feedback 85 General Safety Information 88 The Waste Electrical and Electronic Equipment (WEEE) Directive Agilent Technologies on Internet 94 1290 Infinity Thermostat User Manual
Open the catalog to page 41290 Infinity Thermostat User Manual
Open the catalog to page 51 Introduction Introduction to the Thermostat Introduction to the Thermostat The Agilent 1290 Infinity Thermostat is designed for use with other modules of the Agilent 1200 Infinity Series or with other LC systems if adequate remote control inputs and outputs are available. The thermostat is controlled from the Agilent 1200 Infinity Series Instant Pilot or from your Agilent control software for LC systems. The specially-designed thermostattable sample trays holds either 100 × 1.8 mL vials or two wellplates and 10 × 1.8 mL vials. The thermostat contains Peltier-controlled heat exchangers. A...
Open the catalog to page 6Heat sink fans Power supply Heat sink Heat exchanger Condensation leak drain Figure 1 Overview of the Thermostat 1290 Infinity Thermostat User Manual
Open the catalog to page 7Thermostat Operation Thermostat Operation Heat exchanger Special sample tray autosampler sampling unit Heating/cooling module Peltier elements Figure 2 Thermostat Principle The thermostat is equipped with a cooling/heating module which uses Peltier elements for efficient air cooling. When turned on the front side of the Peltier elements is heated/cooled according to the temperature setting. A fan draws air from the sample tray area and blows it through the channels of the heating/cooling module. The fan speed is determined according to the environmental conditions (e.g., ambient...
Open the catalog to page 8Introduction Thermostat Operation 1 heating/cooling module the air reaches the temperature of the Peltier elements and this thermostatted air is blown underneath the special sample tray where it is evenly distributed and streams back into the sample tray area. From there it is again drawn into the thermostat. This “recycle” mode assures a very efficient cooling/heating of the sample vials. In cooling mode the opposite side of the Peltier element will become very hot and to maintain the performance of the elements they have to be cooled down. This is done with large heat exchangers in the...
Open the catalog to page 9Thermostat Operation 1290 Infinity Thermostat User Manual
Open the catalog to page 101290 Infinity Thermostat User Manual Site Requirements and Specifications
Open the catalog to page 112 Site Requirements and Specifications Site Requirements Site Requirements A suitable site environment is important to ensure optimum performance of the instrument. Power Consideration The autosamplers comprises two modules, the autosampler module (G1329A/B, G1367A-E, G1377A, G2260A, G4226A, G5667A, G4303A) or fraction collector (G1364A-C, G1364D, G5664A) and the thermostat module (G1330B). Both modules have a separate power supply and a power plug for the line connections. The two modules are connected by a control cable and both are turned on by the autosampler or fraction collector. The...
Open the catalog to page 122 Site Requirements and Specifications Site Requirements Power Cords Different power cords are offered as options with the module. The female end of all power cords is identical. It plugs into the power-input socket at the rear. The male end of each power cord is different and designed to match the wall socket of a particular country or region. WA R N I N G Absence of ground connection or use of unspecified power cord The absence of ground connection or the use of unspecified power cord can lead to electric shock or short circuit. ➔ Never operate your instrumentation from a power outlet...
Open the catalog to page 132 Site Requirements and Specifications Site Requirements Bench Space The module dimensions and weight (see Table 1 on page 15) allow you to place the module on almost any desk or laboratory bench. It needs an additional 25 cm (10 inches) of space on either side and approximately 8 cm (3.1 inches) in the rear for air circulation and electric connections. If the bench shall carry a complete HPLC system, make sure that the bench is designed to bear the weight of all modules. The module should be operated in a horizontal position. Environment Your modules will work at ambient temperatures and...
Open the catalog to page 14Site Requirements and Specifications 2 Physical Specifications Physical Specifications Table 1 Physical Specifications Type Specification Comments width x depth) (5.5 x 13.5 x 17 inches) Line voltage 100-240 VAC, ± 10 % Wide-ranging Power consumption 260 VA / 210 W/717 BTU Maximum Ambient operating 4-40 °C (39- 104 °F) See warning "Hot rear temperature panel" on page 15 Non-operating altitude Up to 4600 m (15091 ft) For storing the module Safety standards: IEC, CSA, Installation category II, Pollution degree 2 For indoor use only. Using the module at high environmental temperatures may...
Open the catalog to page 152 Site Requirements and Specifications Performance Specifications Performance Specifications Table 2 Performance specifications Agilent 1290 Infinity Thermostat Type Specification Temperature range Settable from 4 °C to 40 °C in 1 ° increments Temperature accuracy at ambient 3 °C to 8 °C at a setpoint of 4 °C* Temperature accuracy at ambient 3 °C to 9 °C at a setpoint of 4 °C* Measurement conditions: with 100-Vial Tray in vial location 2,10,92 and 100 vials filled with water For vials: Using the Thermostattable Tray (G1329-60011) or 100 Micro-Vial For well plates: Standard Tray...
Open the catalog to page 16All Agilent Technologies - Life Sciences and Chemical catalogs and technical brochures
-
Agilent 280 Series AA Systems
12 Pages
-
Inorganic Standards
40 Pages
-
InfinityLab LC Supplies
148 Pages
-
General Chromatography
164 Pages
-
Sample Preparation (2018/2019)
144 Pages
-
MS500
12 Pages
-
FLAME ATOMIC ABSORPTION SPECTROSCOPY
104 Pages
-
Agilent training
27 Pages
-
AGILENT VACUUM PRODUCTS CATALOG
536 Pages
-
Vacuum Measurement Catalog
44 Pages
-
AGILENT ION Pumps
53 Pages
-
AGILENT DIFFUSION PUMPS
35 Pages
-
AGILENT Rotary Vane Pumps
29 Pages
-
Agilent InfinityLab LC Series
16 Pages
-
3100 fractionator
8 Pages
-
4200 MP-AES
12 Pages
-
Agilent GPC/SEC Solutions
12 Pages
-
Agilent?s biomass solutions
12 Pages
-
X-ray Crystallography
12 Pages
-
Agilent ProPulse NMR System
5 Pages
-
An autosampler like no other
4 Pages
-
Agilent U1450A/U1460A
19 Pages
-
Agilent B1507A
22 Pages
-
Agilent M9703A
16 Pages
-
W1905 Radar Model Library
16 Pages
-
M8048A ISI Channels
7 Pages
-
Agilent J-BERT M8020A
27 Pages
-
Agilent N8900 Series
10 Pages
-
I/O Hardware
16 Pages
-
Advanced Design System
16 Pages
-
RF & Microwave Attenuators
4 Pages
-
E4980AL Precision LCR Meter
8 Pages
-
FieldFox Handheld Analyzers
8 Pages
-
AFM/SPM Accessories
20 Pages
-
VEE 9.32
24 Pages
-
89600 VSA Software
9 Pages
-
Command Expert
2 Pages
-
E5061B Network Analyzer
8 Pages
-
E5071C ENA Network Analyzers
18 Pages
-
N9038A MXE EMI Receiver
2 Pages
-
N9322C Basic Spectrum Analyzer
10 Pages
-
Digital Multimeters
25 Pages
-
M9361A PXI Downconverter
2 Pages
-
Power Meters and Power Sensors
34 Pages
-
E7515A UXM Wireless Test Set
2 Pages
-
Agilent Power Products
31 Pages
-
E5063A Network Analyzer
8 Pages
-
Leak Detection Catalog
41 Pages
-
Agilent 7820A GC brochure
8 Pages
-
Agilent GC-MSD and QTOF
96 Pages
-
Agilent GC-MSD 5977
39 Pages
-
Agilent Intro BERLIN
24 Pages
-
1290 Infinity Quaternary LC
24 Pages
-
1260 Infinity Bio-inert
26 Pages
Archived catalogs
-
Diffusion Pumps Catalog
37 Pages