Oxygen Removal System AGC 75-900

Oxygen Removal System AGC 75-900

Product catalog summary
Overview: The Model AGC 75-900 De-OX is an oxygen removal system designed for analyzing the purity of oxygen by detecting trace levels of nitrogen (N2), argon (Ar), and methane (CH4) in high purity oxygen standards. It is capable of analyzing oxygen to the part-per-billion level.
Specifications: The system includes a 2m x 1/8” pre-column and an O2 Trap. The pre-column allows for baseline separation of components, while the O2 Trap captures oxygen from the sample. The system uses a reducing gas, such as hydrogen (H2) or carbon monoxide (CO), to react with copper (Cu) to form copper oxide (CuO), which is then reduced back to copper, releasing water (H2O).
Procedures: The system operates by injecting a gas sample that passes through the pre-column and O2 Trap. A valve switches the flow to route the reducing gas over the catalyst. The system is ready for analysis within a few hours.
Performance: The Model AGC 75-900 De-OX, in conjunction with the AGC Series 100 DID Gas Chromatograph, has demonstrated effective analysis of oxygen purity to the part-per-billion level, despite potential anomalous peaks during base oxygen analysis.
Contact Information: AGC Instruments is headquartered in Shannon Free Zone West, Shannon, Co. Clare, Ireland. Contact can be made via phone at +353 61 471632, fax at +353 61 471042, or email at [email protected]. More information is available at www.agc-instruments.com.
See more

Catalog excerpts

Oxygen Removal System AGC 75-900-1

The Model AGC 75-900 De-OX is designed to analyse oxygen purity with a gas chromatograph. It is used specifically for measuring very low concentrations of impurities in oxygen base gas such as Nitrogen, Argon, and Methane. Exposure of the oxygen sample to a catalyst after injection with a gas sample valve results in oxidation of the copperbased catalyst, leaving the remaining impurities in the sample/helium carrier stream. (Impurities + 02) + Cu ^ CuO2 + Impurities The Trap can be regenerated after approximately 200 samples (using a 2 cc sample) by switching a valve that routes a reducing gas, i.e., H2 or CO, over the catalyst. In a few hours, the AGC Model 75-900 De-OX is ready again for operation. The Trap can be cycled indefinitely unless abused. H2 + CuO ^ Cu + H2O A special column configuration is required for use with the AGC Discharge Ionization Detector (DID)* used for the analysis of ppb levels of impurities in base gases. The AGC research in this application has shown that anomalous peaks can occur when analyzing the base oxygen. The chromatography required for good analytical data is provided when purchasing the Model AGC 75-900 system. A 2m x 1/8" pre-column of molecular sieve will separate the impurities found in the Oxygen sample and those possibly manufactured impurities found in the reagent material used in the Trap. The pre-column is positioned after the gas sample valve and before the O2 Trap. An injected gas sample passes through the pre-column then through the O2Trap where the oxygen is captured. The impurities pass onto the analytical column, then into the detector. The precolumn will delay the sample impurities which will result in a longer retention time than any anomalous peaks generated by the catalytic reaction. The AGC Model 75-900 De-OX detection limit for the impurities in Oxygen, such as N2, Ar, and CH4 is dependent upon the detection capability of the detector in the gas chromatograph. The Model ATC 75-900 de-OX and the AGC Series 100 DID Gas Chromatograph have demonstrated the analysis of Oxygen to the part-per-billion level. Headquarters Shannon Free Zone West, Shannon, Co. Clare, Ireland T: +353 61 471632 F: +353 61 471042 E: [email protected] A certified helium standard containing 2 ppm of N2, Ar, CH4, and CO should be analyzed first to determine retention times of each of the components. This chromatogram shows the analysis of a commercially available high purity oxygen standard. The pre-column has allowed baseline separation from the ppb Ar, N2, and ch4 Oxygen standard. The anomalous peaks can be ignored and the resulting chromatogram is an analysis of part-per-billion levels of Ar, N2, and CH4 in O2.