NovaCHROM 5000 GC
4Pages

{{requestButtons}}

Catalog excerpts

NovaCHROM 5000 GC - 1

Gas Chromatograph ppm to low ppb SULPHUR analysis using a Flame Photometric Detector Features The new NovaCHROM 5000 GC contains the latest GC technology based around the industry proven double Flame Photometric Detector (FPD). This sulphur selective detector, of which AGC Instruments has extensive experience, is ideal for characterising and quantifying a wide range of low level sulphur species in gaseous streams. Utilising the latest advanced technologies, this GC provides customers with the precise results they require with the ease of use and support features expected. The NovaCHROM 5000 detects and identifies individual sulphur species as opposed to total sulphur values and there is no interference from matrix gases which occurs in spectrometry analysers. Multiple column ovens, with heated valves to eliminate cold spots, are combined with passivated tubing to maximise sensitivity and achieve ultra low ppb levels. As a result, quick analysis times are achieved of between one to five minutes typically. AGC Instruments will custom design an analytical solution to meet your application. All systems are constructed using pipework not exceeding 1/8” in diameter and using only Swagelok® stainless steel fittings. The flow paths are contamination free and allow a fresh sample to reach the detector with speed. This is coupled with the ability to purge the valves and column ovens with an inert gas. Teflon tubing and heated lines are employed where necessary as well as flame-off and flow restrictor safety features. Furthermore, the NovaCHROM 5000 can be used with Natural Gas and ATEX versions are available upon demand. Measurements are achieved with ease and with minimal training required using the new interactive touch screen. The new Electronic Pressure & Flow Management System has ensured all functionality is easy and accessible also. The constant monitoring of critical status information such as flows, pressures and temperatures is readily available to the operator and is backed up with the Alarm activation function. This allows feedback locally to other locations such as the Control Room or DCS. As a result, this robust system ensures a consistent performance with excellent stability, sensitivity and a long working life. Double Flame Photometric Detector (FPD) Ideal for the analysis of Sulphurous species such as H2S , COS , CS2 , Mercaptans and Sulfides Accuracy Example: 0.01 ppm of 2.55ppm H2S in Natural Gas Fast Detector Response: < 0.5 seconds (90%) Versatile & Robust Detector design Cost Effective and Reliable Electropolished Stainless Steel Tubing passivated for Sulphur Teflon Tubing & Heated Lines depending on application Packed, Micro-Packed & Capillary Columns for Maximum Sensitivity Multiple Column Ovens with individual temperature control, heated gas sampling & column switching valves to eliminate cold spots Electronic Pressure & Flow Management System Long Term Stability & Sensitivity Automated use with large colour 6.5” LCD Touch Screen Integrated Configurable Alarms System Integrated Diagnostics System Full Control by TrendVision PLUS Software Increased Connectivity with both USB, RS-232 and RS-485 Drop Down Front Panel for easy access during maintenance Built-in Safety Features such as Flame-Off Protection...etc.

Open the catalog to page 1
NovaCHROM 5000 GC - 2

Principle Of Operation The AGC NovaCHROM 5000, uses a double Flame Photometric Detector (FPD) which is designed to give a selective response to sulphur (or phosphorous) compounds. When an excitation energy is applied to the atoms of an element, a photometric emission spectrum is obtained whose wavelength is characteristic of the element. The intensity of the emitted light is proportional to the number of excited atoms. Within the flame photometric detector, the excitation energy is derived from the dual-heat zone combustion of the sample in a hydrogen-rich flame. This double flame...

Open the catalog to page 2
NovaCHROM 5000 GC - 3

Specification Detector Double Flame Photometric Detector (FPD) < 20pg S/sec for Thiophene (Sulphur Mode) Accuracy Examples 0.01 ppm Standard Deviation on 2.55 ppm H2S in Natural Gas 0.02 ppm Standard Deviation on 1.62 ppm COS in Natural Gas Minimum Detectable Level Detector Response Time Temperature Range 19” Rack, Bench Top or Wall Mount 6.5” LCD Colour Display with LED backlight and resistive touch screen Nitrogen (N2), Helium (He), Argon (Ar) : <5ppm H2O free from CnHm 20-40mL/min Support Gases 500 mL/min flow (200ml/min flow recommended) 5-10 Bar input: Controls Carrier Gas Output from...

Open the catalog to page 3
NovaCHROM 5000 GC - 4

Company Profile AGC Instruments AGC Instruments is a leading manufacturer of Gas Analysis Solutions to all users requiring a Quality Control or identification of their gas stream. We have over 50 years experience in providing our customers with their “Total Gas Analysis Solutions”. We work closely with all customers to ensure they obtain the analytical solution that meets their needs and a system that is easy to use and understand. All AGC distributors are extremely experienced and factory trained to the highest standards, offering you a complete after sales support service. The wide range...

Open the catalog to page 4