Overview: The NovaCHROM 4000 Gas Chromatograph by AGC Instruments is designed for precise analysis of gas mixtures using a Thermal Conductivity Detector (TCD). It is ideal for permanent gas analysis, offering cost-effectiveness, reliability, and ease of use.
Key Features:
  • Thermal Conductivity Detector (TCD) with sensitivity to ppm levels and accuracy to <5ppm.
  • Fast detector response time of <1 second (90%).
  • Large 6.5” LCD touch screen for user-friendly operation.
  • Fully automated with integrated diagnostics and configurable alarms.
  • Versatile with packed, micro-packed, and capillary columns for maximum sensitivity.
  • Independent column ovens with individual temperature control.
  • Enhanced connectivity options including USB, RS-232, and RS-485.
Principle of Operation: The TCD uses four sensing elements in a Wheatstone bridge circuit to measure changes in thermal conductivity of sample gases, providing output voltage changes measurable by data capture systems like TrendVision PLUS Software.
TrendVision PLUS Software: This software offers a unified chromatography method with settings for event tables, calibration, and integration. It supports unattended operation and can communicate results using fieldbus protocols or traditional signaling.
Specifications:
  • Detector: TCD with excellent repeatability and auto-calibration.
  • Temperature Range: Operating 30-45°C, Ambient +10°C to +30°C.
  • Response Time: <0.5 seconds (90%).
  • Power: 230 V AC / 50 Hz or 115V AC / 60Hz, 300W.
  • Interface: 6.5” LCD Colour Display with touch screen.
  • Carrier Gas: Helium, Argon, Hydrogen, or Nitrogen.
Applications: Suitable for various industries including industrial gas production, petrochemical refineries, natural gas analysis, and pharmacopeia applications.
Aftersales Care: AGC Instruments provides comprehensive after-sales support through trained distributors and online customer support.
Company Profile: AGC Instruments is a leading manufacturer of gas analysis solutions with over 50 years of experience, offering a range of detectors and emphasizing continuous development and customer support.
See more

Catalog excerpts

NovaCHROM 4000 GC-1

Gas Chromatograph % and ppm analysis using a Thermal Conductivity Detector Features The new NovaCHROM 4000 GC is built on the platform of the successful AGC Series 100 TCD Gas Chromatograph. This versatile and robust detector design, of which AGC Instruments is a leading supplier worldwide, is ideal for permanent gas analysis and its universal applicability ensures that it is both cost effective and reliable. Utilising the latest advanced technologies, this GC provides customers with the precise results they require with the ease of use and support features expected. Thermal Conductivity Detector (TCD) Accuracy to <5ppm (application dependent) Fast Detector Response time of < 1 Ideal for Permanent Gas Analysis Versatile & Robust Detector design Universal Detector Cost Effective and Reliable The NovaCHROM 4000 GC uses an industry proven method of analysis for the quality control of gases: the Thermal Conductivity Detector (TCD). This detector is ideal for measuring impurities from % to ppm and minimal training is required. The interactive touch screen uses an easy-to-use user interface for guided functionality and this enables the operator to achieve guaranteed applications with ease. Therefore, the NovaCHROM 4000 GC provides a top class service to you at all times. Large Colour 6.5” LCD Touch Screen Long Term Stability & Sensitivity Electropolished Stainless Steel Tubing Integrated Configurable Alarms System Packed, Micro-Packed & Capillary Columns for Maximum Sensitivity 1/8” Stainless Steel Swagelok fittings are combined with Vici Valco high purity rotary valves to guarantee a contamination free environment that will provide excellent stability, sensitivity and a long working life. The AGC engineering design team will devise a solution specified to suit the application at hand. Furthermore, all systems can be designed for corrosive applications with corrosion resistant materials employed throughout. Independent Column Ovens with individual Temperature Control Integrated Diagnostics System Full Control by TrendVision PLUS Software Increased Connectivity with both USB, RS-232 and RS-485 Drop Down Front Panel for easy access to electronics

 Open the catalog to page 1
NovaCHROM 4000 GC-2

Principle Of Operation The AGC NovaCHROM 4000, using the Thermal Conductivity Detector (TCD), is typically used for the precise analysis of the components in multiple gas mixtures at percentage and ppm levels. The TCD has four sensing elements which are connected to form an electrical Wheatstone bridge circuit. These elements are typically miniature rhenium-tungsten filaments which are mounted in a metallic cell block. A flow through type thermal conductivity cell is normally used in this analyser. This cell contains a sample and reference gas flow geometry and two elements are installed in each...

 Open the catalog to page 2
NovaCHROM 4000 GC-3

Specification Detector Thermal Conductivity Detector (TCD) Excellent Repeatability with auto-calibration function in TrendVision PLUS 1ppm over 48 hours (ppm application) Temperature Range Detector Response Time 10 μV maximum, depending on operating parameters 19” Rack, Bench Top or Wall Mount 6.5” LCD Colour Display with LED backlight and resistive touch screen Helium (He), Argon (Ar), Hydrogen (H2) or Nitrogen (N2) 5-10 Bar input: Controls Carrier Gas Output from 0-5 bar 10 - 500 mL/min flow (200ml/min flow recommended) Vici Valco high purity rotary valves Standard Fittings 1/8” Stainless Steel...

 Open the catalog to page 3
NovaCHROM 4000 GC-4

Company Profile AGC Instruments AGC Instruments is a leading manufacturer of Gas Analysis Solutions to all users requiring a Quality Control or identification of their gas stream. We have over 50 years experience in providing our customers with their “Total Gas Analysis Solutions”. We work closely with all customers to ensure they obtain the analytical solution that meets their needs and a system that is easy to use and understand. All AGC distributors are extremely experienced and factory trained to the highest standards, offering you a complete after sales support service. The wide range of...

 Open the catalog to page 4
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.