Building technology/industry Gas alarm unit GW-S in wall mounting housing ■■ ■■ For two or four gas sensors (measuring points) Digital display for concentration, programming and calibration data Alarms: memory mode or volatile mode (1–2) Self-monitoring for line interruption, short circuit and power failure For continuous monitoring of inflammable or toxic gases as well as oxygen in ambient air. Ideal for industrial and building technology applications. Not suitable for use in hazardous areas (EX areas). Freely programmable gas alarm unit in a compact wall mounting housing for the connection of one or two gas sensors. The control unit can monitor various types of gases. GW-S can be operated in single-stage or dual-stage mode. Limit values can be set as required. Four integrated relays can be assigned as required (1 relay is used for general alarm and 1 relay for the audible alarm signal (horn). The other relays are available for control outputs. The gas alarm system features a display with alternating indication of measured values and three operating levels: 1. Measurement level: Displays measured values, faults, alarms 2. Parameter level: Displays measuring ranges, limit values, alarm groups 3. Service level: Displays limit values, performs function checks of the relays, setting of parameters (such as alarm group and limit value settings) GW-S alternately displays the concentration of the gas in the ambient air. If a sensor exceeds alarm level 1 or alarm level 2, the visual alarm and the alarm relay are activated. When the concentration falls below the alarm level, the alarm is cleared. It is also possible to program GW-S in such a way that alarm level 2 remains stored until a manual reset. The activation of the relay for the horn can also be programmed for each alarm level. Stop mode allows for permanent indication of the concentration at a given measuring point. GW-S is self-monitoring (line interruption, short circuit and power failure) and signals faults via LED and fault relay. In addition, the display shows an "E". The alarm function can be tested without test gas. Version GW-S4 for connection of up to four gas sensors. Technical specifications Sensor inputs 4–20 mA GW-S: 2 gas sensors can be connected GW-S4: 4 gas sensors can be connected Housing Wall mounting housing W x H x D: 195 x 160 x 137 mm Weight: 1.3 kg Degree of protection: IP 54 (EN 60529) Alarm thresholds Max. 2, adjustable, memory mode or volatile mode Connectable sensors Series 400, 500, 600, 700 and 800 Switching outputs 4 voltage-free relay contacts Option Controls ■■ Data logger Keypad for alarm and horn reset, edit, menu selection, confirmation Display Digital display for: concentration value, menu LEDs for: ■■ Alarm and fault for each measuring point ■■ Operational, horn and indicated measuring point Supply voltage: AC 230 V Power input: Max. 20 VA i Suitable gas sensors (series 400−800) see page 118–119. Operating temperature range Ambient: -10/+40 °C Version with data logger

Open the catalog to page 1

All AFRISO-EURO-INDEX catalogs and technical brochures

  1. s022

    1 Pages

  2. s025

    1 Pages

  3. s033

    1 Pages

  4. s056

    3 Pages

  5. s058

    2 Pages

  6. s062

    1 Pages

  7. s112

    1 Pages

  8. s113

    1 Pages

  9. s114

    1 Pages

  10. S286

    3 Pages

Archived catalogs

  1. EUROLYZER ST

    2 Pages