s112

s112

Product catalog summary
Overview: This document provides technical specifications and application details for gas alarm units GS 1.1 and GS 2.1, designed for residential use to detect inflammable gases such as methane, propane, and butane.
Technical Specifications:
  • Supply Voltage: AC 230 V
  • Dimensions: 158 x 90 x 44 mm
  • Protection Degree: IP 20 (EN 60529)
  • Operating Temperature: 0/50 °C; max. 75% relative humidity
  • Alarm Value: Approx. 20% LEL (Lower Explosive Limit)
  • Audible Alarm: Internal buzzer, minimum 50 dB(A)
  • Service Life: Approx. 5 years
Product Variants:
  • GS 1.1 for Methane (Part no. 61184) and Propane/Butane (Part no. 61186)
  • GS 2.1 for Methane (Part no. 61185) and Propane/Butane (Part no. 61187)
Application Description: The gas alarm units are equipped with an integrated semiconductor sensor and alarm buzzer. They feature LEDs for operation (green), alarm (red), and error (yellow), along with Test and Reset buttons. The alarm is activated at approximately 20% of the LEL, and the audible alarm can be muted using the Reset button, while the visual alarm remains active until the condition is resolved.
Additional Features of GS 2.1: Includes a relay output for connecting external alarm equipment and an input for an external gas sensor GS 4.1 to monitor different rooms.
Cross-Sensitivity: GS gas alarm units are sensitive to hydrocarbons, lacquers, solvents, alcohols, and similar substances.
See more

Catalog excerpts

s112-1

Building technology Gas alarm units for the private home Relay for external s e n so r For the detection of inflammable gases such as methane, propane, butane in ambient air in residential buildings. For the detection of inflammable gases such as methane, propane, butane in ambient air in residential buildings. Gas alarm unit with integrated semiconductor sensor and alarm buzzer. LEDs for operation (green), alarm (red), error (yellow), the Test button and the Reset button are located at the front side of the housing. The alarm is triggered when approx. 20 % of the LEL (lower explosive limit) is reached. The audible alarm can be muted with the Reset button. The visual alarm remains active until the alarm condition no longer exists (reset). Gas alarm unit with integrated semiconductor sensor, alarm buzzer and relay output for connection of additional external alarm equipment (e.g. horn). LEDs for operation (green), alarm (red), error (yellow), the Test button and the Reset button are located at the front side of the housing. The alarm is triggered when approx. 20 % of the LEL (lower explosive limit) is reached. The audible alarm can be muted with the Reset button. The visual alarm remains active until the alarm condition no longer exists (reset). The unit features an additional input for connection of an external gas sensor GS 4.1 as a second measuring point for monitoring different rooms. Technical specifications Housing W x H x D 158 x 90 x 44 mm Degree of protection: IP 20 (EN 60529) Housing W x H x D 158 x 90 x 44 mm Degree of protection: IP 20 (EN 60529) Operating temperature range Ambient: 0/50 °C; max. 75 % rH Operating temperature range Ambient: 0/50 °C; max. 75 % rH Alarm value: Approx. 20 % LEL Alarm value: Approx. 20 % LEL Audible alarm: Internal buzzer, min. 50 dB(A) Audible alarm: Internal buzzer, min. 50 dB(A) Service life: Approx. 5 years Service life: Approx. 5 years i GS gas alarm units are cross-sensitive to hydrocarbons, lacquers, solvents, alcohols and similar media. Gas alarm unit GS 1.1 Methane Gas alarm unit GS 1.1 Propane/Butane Gas alarm unit GS 2.1 Methane Gas alarm unit GS 2.1 Propane/Butane

 Open the catalog to page 1

All AFRISO-EURO-INDEX catalogs and technical brochures

  1. s022

    1  Page

  2. s025

    1  Page

  3. s033

    1  Page

  4. s056

    3  Pages

  5. s058

    2  Pages

  6. s062

    1  Page

  7. s116

    1  Page

  8. s113

    1  Page

  9. s114

    1  Page

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.