s022
1Pages

{{requestButtons}}

Catalog excerpts

s022 - 1

Capacitance level indicator with EX approval CapFox® S 74x 1 For liquid and powdery media Various probes available for optimum adaptation to the process Hazardous area Non-hazardous area For continuous level measurement in tanks and containers in hazardous areas, Ex zones 0, 1 and 2. Suitable for liquid, powdery, electrically conductive or non-conductive media. Also suitable for pressurised or vacuum tanks. The capacitance level indicator consists of the control unit CapFox® S 74x with digital display, a probe and an EX pre-amplifier which is factory-mounted in the probe head. CapFox® S 74x has an intrinsically safe power circuit. In order to ensure the intrinsic safety of the circuit, the S 74x control unit may only be operated in conjunction with the HF pre-amplifier (part no. 51791) and a capacitance rod probe type 88. The control unit must be installed outside of the hazardous area. The choice of measuring probe (partially or fully insulated, rigid) depends on the properties of the medium to be measured and the shape of the tank. Fully insulated probes must be used for conductive media. The probes are equipped with a capacitance voltage transducer (HF probe insert) in the probe head and are mounted vertically. Technical specifications Measuring range 0/200 mm to 0/3,000 mm, depending on selected probe Measuring accuracy ±1.5 % FS Operating temperature range Ambient: -10/+50 °C Process pressure Depending on selected probe Display 3½ digit LCD Resolution 0.1 % (±1 digit) Displayed values 0/100 % liquid level Supply voltage AC 230 V or DC 24 V Power input 5 VA Housing Wall mounting housing with plug-in base made of impact-resistant plastic (ABS) W x H x D: 76 x 150 x 115 mm Degree of protection IP 30 (EN 60529) EX approval II (1) G [Ex ia] II C T6 BASEFA 02ATEX0088 HF pre-amplifier EX HF pre-amplifier insert part no. 51791 exclusively for the CapFox® S 74x to ensure the intrinsic safety of the circuit. The pre-amplifier is factorymounted in the probe head. Scope of order Complete measuring system (items to be ordered separately): ■■ Control units S 74x ■■ HF probe insert part no. 51791 ■■ Rod probe series 88 ■■ Concentric shielding tube Outputs 0–10 V/0–1 mA /4–20 mA Visual indication Yellow LED: Power on Intrinsically safe circuit UM = 250 V, U0 = 13.0 V, I0 = 76 mA P0 = 0.25 W, C0 = 1.0 µF, L0 = 6.1 mH i Probes and accessories see page 23–24.

Open the catalog to page 1

All AFRISO-EURO-INDEX catalogs and technical brochures

  1. s025

    1 Pages

  2. s033

    1 Pages

  3. s056

    3 Pages

  4. s058

    2 Pages

  5. s062

    1 Pages

  6. s112

    1 Pages

  7. s116

    1 Pages

  8. s113

    1 Pages

  9. s114

    1 Pages

  10. S286

    3 Pages

Archived catalogs

  1. EUROLYZER ST

    2 Pages