  3. PrimoTherm 180-3 RTA - Heating pump assemblies

PrimoTherm 180-3 RTA - Heating pump assemblies

PrimoTherm 180-3 RTA - Heating pump assemblies

PrimoTherm 180-3 RTA - Heating pump assemblies

Product catalog summary
Overview
The document describes the PrimoTherm® 180-3 RTA heating pump assembly designed to increase the return temperature of system water to solid fuel boilers. This helps maintain the boiler temperature above the condensation point, reducing deposits and extending the system's service life.

Key Features
  • Temperature-controlled condensation protection valve with preset temperatures of 45 °C, 55 °C, and 60 °C.
  • Pre-assembled, tightness-tested, and heat-insulated.
  • High energy efficiency pump, ErP-Ready, with modular system for flexible installation.
  • Integrated gravity brake and second ball valve for easy pump replacement.

Application
The assembly is suitable for heating systems with a capacity of up to 32 kW and a flow rate of up to 1,400 l/h. It prevents corrosion and chimney fires by avoiding soot deposits.

Technical Specifications
  • Axis distance: 125 mm
  • System connections: G1 female thread
  • Operating temperature range: Medium Tmax 100 °C
  • System pressure: Max. 10 bar
  • Nominal size: DN 25
  • Insulation: Polypropylene EPP, IP 42
  • Dimensions: 250 x 475 x 153 mm

Operation Phases
  1. Start Mode: The thermal valve remains closed until the boiler reaches the opening temperature, recirculating liquid to increase boiler temperature.
  2. Transition Phase: Upon reaching the opening temperature, the circuit to the consumer opens proportionally.
  3. Regular Operation: The thermal valve fully opens as temperature increases, closing the bypass proportionally.

Product Variants
Several versions are available with different opening temperatures and configurations, including options without a pump.
See more

Catalog excerpts

PrimoTherm 180-3 RTA - Heating pump assemblies-1

Fig. shows high-efficiency pump WILO YONOS PARA 25/6 Heating pump assemblies for increased return temperature with solid fuel boilers Your benefits With temperature-controlled condensation protection valve ossible preset temperatures: 45 °C, 55 °C, 60 °C P reduced amounts of condensate in the combustion process For voids deposits in the boiler and in the smoke vent A Pre-assembled, tightness-tested and heat-insulated assembly lass A high energy efficiency pump, ErP-Ready C odular system with flow at left or right, horizontal or M vertical installation ntegrated gravity brake in the ball valve of the flow line I Second ball valve in the return line allows for replacement of pump without draining the system Application Heating pump assembly for increasing the return temperature of the system water to the solid fuel boiler. This keeps the temperature in the heating boiler above the condensation point in all operating states. It also avoids deposits in the boiler and in the smoke vent Form-fit insulation: Many standard pumps can be installed without refitting of the insulation and increases the service life of the system. The risk of corrosion damage to the boiler and chimney fires resulting from soot deposits is reduced. The pump assembly is designed for a capacity of up to 32 kW and a flow rate of up to 1,400 l/h.

 Open the catalog to page 1
PrimoTherm 180-3 RTA - Heating pump assemblies-2

Solid fuel boiler Solid fuel boiler Solid fuel boiler Start mode (heating up of boiler) Transition phase when opening temperature is reached Regular operation When the boiler heats up, the thermal valve is fully closed in the direction of the consumer (inlet A). It remains closed until the liquid heated up by the boiler has reached the opening temperature of the thermal valve (e.g. 55 °C). During this time, the liquid coming from the boiler is recirculated in the small circuit (bypass B), which causes the boiler temperature to increase more rapidly. When the opening temperature is reached (e.g....

 Open the catalog to page 2

All AFRISO-EURO-INDEX catalogs and technical brochures

  1. s022

    1  Page

  2. s025

    1  Page

  3. s033

    1  Page

  4. s056

    3  Pages

  5. s058

    2  Pages

  6. s062

    1  Page

  7. s112

    1  Page

  8. s116

    1  Page

  9. s113

    1  Page

  10. s114

    1  Page

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.