1. Catalogs
  2. AFRISO-EURO-INDEX
  3. Measuring and control technology for hygienic processes

Measuring and control technology for hygienic processes

Measuring and control technology for hygienic processes
1 / 16 PagesView full catalog

Measuring and control technology for hygienic processes

Product catalog summary
Overview
AFRISO provides advanced measuring and control technology solutions for industries such as beverages, food, biotechnology, and pharmaceuticals. These solutions ensure process reliability through sterile process separation, hygienic design, superior material quality, and maximum measuring accuracy.
Specifications and Standards
AFRISO products adhere to various national and international standards, including GMP, FDA, ATEX, SIL, GOSSTANDART, PED, EHEDG, and 3-A. These standards guarantee product quality and safety in hygienic processes, focusing on material quality, design, and cleanability.
Product Features
AFRISO offers products like pressure gauges, pressure transmitters, and diaphragm seals, featuring hygienic design with materials such as stainless steel and FDA-listed coatings. They are resistant to cleaning agents and temperature variations, with various process connections for optimal application adaptation, complying with EHEDG and 3-A standards.
Technological Innovations
AFRISO utilizes advanced technologies, including seal-free diaphragm seals and sophisticated kit systems, to optimize production facilities. Their products prevent contamination and ensure easy cleaning through methods like CIP (Cleaning in Place) and SIP (Sterilization in Place).
Applications
AFRISO's technology is suitable for hygienic processes in food, cosmetics, and pharmaceutical manufacturing, designed to withstand harsh conditions and provide accurate measurements, ensuring safety and quality.
Specifications
The document details temperature and level measurement devices, with temperature ranges from -50°C to +500°C and various process connections. Resistance thermometers are noted for high accuracy and short response times, with hygienic designs and ATEX approval.
Procedures
Installation lengths and process connections for sensors are discussed, emphasizing the importance of selecting the right configuration. The integration of transducers for enhanced functionality is also mentioned.
Standards and Norms
Devices comply with standards such as EN 13190 and IEC 751, ensuring accuracy and reliability. DIN 16195 for accuracy and EHEDG recommendations for hygienic design are also referenced.
Recommendations
The document suggests using specific devices for demanding applications, highlighting features like vibration resistance and high accuracy. It also recommends AFRISO's service and rental options for maintenance and operational continuity.
Key Data from Tables and Graphs
Detailed specifications for each device, including measuring ranges, sensor types, and output signals, are provided. Process connections and installation lengths are listed, offering a comprehensive overview of available options.
Company Profile
AFRISO is a family-owned company with over 140 years of experience in measuring and control technology. It operates globally with 1,000 employees and exports to 60 countries, offering a wide range of products and services, including custom solutions and after-sales support.
See more

Catalog excerpts

Measuring and control technology for hygienic processes-1

Measuring and control technology

 Open the catalog to page 1
Measuring and control technology for hygienic processes-3

Pressure. Temperature. Level. A comprehensive range of measuring technology for hygienic systems and Druck. Temperatur. Füllstand. processes. Das komplette Programm für hygienegerechte Anlagen und Prozesse. Abgestimmt auf die spezifischen ProduktiInnovation und Entwicklungsgeschwindigkeit onsverfahren erfüllen Komponenten und Löbestimmen die Produktionsabläufe in der Gesungen von AFRISO diese hohen Ansprüche tränke-, Nahrungs- und Genussmittelindustrie sowie gesetzliche und empfohlene Hygienerewie auch in der Biotechnik und Pharmazie. Die gularien. Unsere robusten Messgeräte liefern Fertigungsbedingungen...

 Open the catalog to page 3
Measuring and control technology for hygienic processes-4

We know your industry. Requirements for sterile processes Manufacturing and processing food, cosmetics and pharmaceuticals involve highly demanding production technologies. A vast array of standards and stringent directives cover all aspects of the hygienic design of machines, systems and, of course, peripheral equipment such as measuring instruments. AFRISO products consider these standards. National and international approvals and certificates ensure superior quality Good Manufacturing Practice GMP is based on special directives implemented to improve and secure the quality of drugs as well...

 Open the catalog to page 4
Measuring and control technology for hygienic processes-5

Measuring technology for hygienic processes Hygienic production equipment is designed in such a way as to avoid external contamination and microbiological pollution and to ensure easy cleaning. All wetted parts, i. e. materials coming into contact with the medium, must have been tested and classified as hygienic. The materials used in hygienic AFRISO measuring systems meet FDA requirements for contact with food and drugs as per CFR (Code of Federal Regulations), part 21. These materials comprise metals as well as elastomers for seals or oils for transmission in diaphragm seals. The EHEDG recommendations...

 Open the catalog to page 5
Measuring and control technology for hygienic processes-6

Mechanical and electronic Robust pressure gauges a transmitters Bourdon tube and capsule type pressure gauges Measuring system and housing made of stainless steel ousing welded to process H connection Available with optional housing filling indow made of safety glass W or acrylic glass Nominal size 50 – 63 – 100 – 160 Accuracy class 1.0 or 1.6 Range -25/0 mbar to -1000/0 mbar -1/0 bar to -1/+15 bar 0/0.6 bar to 0/4000 bar Temperature range Medium: Tmax +150 °C Ambient: -20/+60 °C Bourdon tube pressure gauges with electrical contacts p to 4 contacts possible U Electrical contact as magnetic spring...

 Open the catalog to page 6
Measuring and control technology for hygienic processes-7

c pressure measurement: and sensitive pressure Field housing for DMU available on request Pressure transducer DMU 04 MR Low measuring ranges possible Optional field housing Optional ATEX approval Measuring range -1/0 bar and -1/+5 bar 0/0.4 bar to 0/40 bar (relative) Transmission medium Multi-grade oil, FDA-listed Output 4-20 mA / 2-wire Temperature range Medium: -25/+125 °C Ambient: -25/+85 °C Process connection Cone connection DIN 11851 N 25 to DN 50 D Pressure transducer DMU 02 Vario BC Pressure transducer DMU 02 Vario CP Connection technology used worldwide Version without internal seals...

 Open the catalog to page 7
Measuring and control technology for hygienic processes-8

Chemical seals For hygienic separation of measuring instrument and Chemical seals Chemical seals are mechanical process separators. They use a diaphragm to separate the medium to be measured from the measuring system. This separating diaphragm is joined to the body of the chemical seal, in hygienic applications usually by means of welding. Chemical seal systems A chemical seal system consists of two connected devices (instrument and seal). Welding or screwing turn the chemical seal and the instrument (e. g. Bourdon tube pressure gauge, pressure transducer or pressure switch) into a single, inseparable...

 Open the catalog to page 8
Measuring and control technology for hygienic processes-9

Diaphragm seals with screwed pipe connections Diaphragm seals with clamp connection iary fitting according to stanD dard 3-A-certified in conjunction with various pressure gauges deal for diary and fruit juice I plants Connection technology used worldwide Easy installation Measuring range -1/0 bar and –1/+24 bar 0/0.6 bar to 0/40 bar Transmission medium Multi-grade oil, FDA-listed Transmission medium Multi-grade oil, FDA-listed Process connection ■ Tapered/threaded socket DIN 11851 (DIN 11887), DN 25 to DN 65 ■ Tapered/threaded socket SMS 1147 1½" to 2½", DIN 11864 Materials According to the...

 Open the catalog to page 9
Measuring and control technology for hygienic processes-10

Mechanical and electronic t Versatile and application-sp Bimetalthermometers Proven technology For temperatures up to 160 °C Nominal size 63 – 80 – 100 Accuracy class (EN 13190) Class 1 Range (°C) -20/+60, 0/60, 0/120, 0/160 Process connection Centre back or bottom Clamp, diary connection or thread for different thermowells Gas filled thermometers with capillary tube High measurement accuracy For remote measurement Nominal size 100 – 160 Accuracy class (EN 13190) Class 1 Range (°C) -20/+60, 0/60, 0/120, 0/160, 0/200, 0/300, 0/400, 0/500 Gas filled thermometers or extremely demanding F measuring...

 Open the catalog to page 10
Measuring and control technology for hygienic processes-11

temperature measurement: pecific Pipe temperature sensor RTS with plug-in display n-line measurement for pipes I o sensor damage with highly N viscous media ther measuring ranges O optionally Measuring range 0/150 °C Sensor 1 x Pt 100, 2-, 3- or 4-wire, class B, IEC 751 Output 4–20 mA, 2-wire Resistance thermometer WTh 30 clamp High accuracy Short response time Transducer can be integrated Measuring range -50/+200 °C Resistance thermometer WTh 28 Hygienic process connections such as clamp, VARIVENT®, dairy and many others Optional ATEX approval Measuring range -35/+200 °C Sensor 1 x Pt 100, 2-,...

 Open the catalog to page 11
Measuring and control technology for hygienic processes-12

Individual or complete solu measurement, evaluation a Magnetostrictive level indicator MagFox® MMG 01 or liquid, non-adhesive and F not highly viscous media valuation with microcontroller E High-precision, temperaturecompensated measuring principle Optional ATEX approval Measuring range 0/200 mm to 0/4.000 mm Measuring accuracy ±0.25 mm, resolution < 0,.1 mm Output 4–20 mA, HART (option) Temperature range Medium: -40/+125 °C Ambient: -40/+85 °C Potentiometric level indicator CoFox® CMG 01 For liquid, electrically conductive media Measurements are independent of pressure, temperature, density...

 Open the catalog to page 12

All AFRISO-EURO-INDEX catalogs and technical brochures

  1. s022

    1  Page

  2. s025

    1  Page

  3. s033

    1  Page

  4. s056

    3  Pages

  5. s058

    2  Pages

  6. s062

    1  Page

  7. s112

    1  Page

  8. s116

    1  Page

  9. s113

    1  Page

  10. s114

    1  Page

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.