Measuring and control technology for hygienic processes
16Pages

{{requestButtons}}

Catalog excerpts

Measuring and control technology for hygienic processes - 1

Measuring and control technology

Open the catalog to page 1
Measuring and control technology for hygienic processes - 3

Pressure. Temperature. Level. A comprehensive range of measuring technology for hygienic systems and Druck. Temperatur. Füllstand. processes. Das komplette Programm für hygienegerechte Anlagen und Prozesse. Abgestimmt auf die spezifischen ProduktiInnovation und Entwicklungsgeschwindigkeit onsverfahren erfüllen Komponenten und Löbestimmen die Produktionsabläufe in der Gesungen von AFRISO diese hohen Ansprüche tränke-, Nahrungs- und Genussmittelindustrie sowie gesetzliche und empfohlene Hygienerewie auch in der Biotechnik und Pharmazie. Die gularien. Unsere robusten Messgeräte liefern...

Open the catalog to page 3
Measuring and control technology for hygienic processes - 4

We know your industry. Requirements for sterile processes Manufacturing and processing food, cosmetics and pharmaceuticals involve highly demanding production technologies. A vast array of standards and stringent directives cover all aspects of the hygienic design of machines, systems and, of course, peripheral equipment such as measuring instruments. AFRISO products consider these standards. National and international approvals and certificates ensure superior quality Good Manufacturing Practice GMP is based on special directives implemented to improve and secure the quality of drugs as...

Open the catalog to page 4
Measuring and control technology for hygienic processes - 5

Measuring technology for hygienic processes Hygienic production equipment is designed in such a way as to avoid external contamination and microbiological pollution and to ensure easy cleaning. All wetted parts, i. e. materials coming into contact with the medium, must have been tested and classified as hygienic. The materials used in hygienic AFRISO measuring systems meet FDA requirements for contact with food and drugs as per CFR (Code of Federal Regulations), part 21. These materials comprise metals as well as elastomers for seals or oils for transmission in diaphragm seals. The EHEDG...

Open the catalog to page 5
Measuring and control technology for hygienic processes - 6

Mechanical and electronic Robust pressure gauges a transmitters Bourdon tube and capsule type pressure gauges Measuring system and housing made of stainless steel ousing welded to process H connection Available with optional housing filling indow made of safety glass W or acrylic glass Nominal size 50 – 63 – 100 – 160 Accuracy class 1.0 or 1.6 Range -25/0 mbar to -1000/0 mbar -1/0 bar to -1/+15 bar 0/0.6 bar to 0/4000 bar Temperature range Medium: Tmax +150 °C Ambient: -20/+60 °C Bourdon tube pressure gauges with electrical contacts p to 4 contacts possible U Electrical contact as magnetic...

Open the catalog to page 6
Measuring and control technology for hygienic processes - 7

c pressure measurement: and sensitive pressure Field housing for DMU available on request Pressure transducer DMU 04 MR Low measuring ranges possible Optional field housing Optional ATEX approval Measuring range -1/0 bar and -1/+5 bar 0/0.4 bar to 0/40 bar (relative) Transmission medium Multi-grade oil, FDA-listed Output 4-20 mA / 2-wire Temperature range Medium: -25/+125 °C Ambient: -25/+85 °C Process connection Cone connection DIN 11851 N 25 to DN 50 D Pressure transducer DMU 02 Vario BC Pressure transducer DMU 02 Vario CP Connection technology used worldwide Version without internal...

Open the catalog to page 7
Measuring and control technology for hygienic processes - 8

Chemical seals For hygienic separation of measuring instrument and Chemical seals Chemical seals are mechanical process separators. They use a diaphragm to separate the medium to be measured from the measuring system. This separating diaphragm is joined to the body of the chemical seal, in hygienic applications usually by means of welding. Chemical seal systems A chemical seal system consists of two connected devices (instrument and seal). Welding or screwing turn the chemical seal and the instrument (e. g. Bourdon tube pressure gauge, pressure transducer or pressure switch) into a single,...

Open the catalog to page 8
Measuring and control technology for hygienic processes - 9

Diaphragm seals with screwed pipe connections Diaphragm seals with clamp connection iary fitting according to stanD dard 3-A-certified in conjunction with various pressure gauges deal for diary and fruit juice I plants Connection technology used worldwide Easy installation Measuring range -1/0 bar and –1/+24 bar 0/0.6 bar to 0/40 bar Transmission medium Multi-grade oil, FDA-listed Transmission medium Multi-grade oil, FDA-listed Process connection ■ Tapered/threaded socket DIN 11851 (DIN 11887), DN 25 to DN 65 ■ Tapered/threaded socket SMS 1147 1½" to 2½", DIN 11864 Materials According to...

Open the catalog to page 9
Measuring and control technology for hygienic processes - 10

Mechanical and electronic t Versatile and application-sp Bimetalthermometers Proven technology For temperatures up to 160 °C Nominal size 63 – 80 – 100 Accuracy class (EN 13190) Class 1 Range (°C) -20/+60, 0/60, 0/120, 0/160 Process connection Centre back or bottom Clamp, diary connection or thread for different thermowells Gas filled thermometers with capillary tube High measurement accuracy For remote measurement Nominal size 100 – 160 Accuracy class (EN 13190) Class 1 Range (°C) -20/+60, 0/60, 0/120, 0/160, 0/200, 0/300, 0/400, 0/500 Gas filled thermometers or extremely demanding F...

Open the catalog to page 10
Measuring and control technology for hygienic processes - 11

temperature measurement: pecific Pipe temperature sensor RTS with plug-in display n-line measurement for pipes I o sensor damage with highly N viscous media ther measuring ranges O optionally Measuring range 0/150 °C Sensor 1 x Pt 100, 2-, 3- or 4-wire, class B, IEC 751 Output 4–20 mA, 2-wire Resistance thermometer WTh 30 clamp High accuracy Short response time Transducer can be integrated Measuring range -50/+200 °C Resistance thermometer WTh 28 Hygienic process connections such as clamp, VARIVENT®, dairy and many others Optional ATEX approval Measuring range -35/+200 °C Sensor 1 x Pt 100,...

Open the catalog to page 11
Measuring and control technology for hygienic processes - 12

Individual or complete solu measurement, evaluation a Magnetostrictive level indicator MagFox® MMG 01 or liquid, non-adhesive and F not highly viscous media valuation with microcontroller E High-precision, temperaturecompensated measuring principle Optional ATEX approval Measuring range 0/200 mm to 0/4.000 mm Measuring accuracy ±0.25 mm, resolution < 0,.1 mm Output 4–20 mA, HART (option) Temperature range Medium: -40/+125 °C Ambient: -40/+85 °C Potentiometric level indicator CoFox® CMG 01 For liquid, electrically conductive media Measurements are independent of pressure, temperature,...

Open the catalog to page 12

All AFRISO-EURO-INDEX catalogs and technical brochures

  1. s022

    1 Pages

  2. s025

    1 Pages

  3. s033

    1 Pages

  4. s056

    3 Pages

  5. s058

    2 Pages

  6. s062

    1 Pages

  7. s112

    1 Pages

  8. s116

    1 Pages

  9. s113

    1 Pages

  10. s114

    1 Pages

  11. S286

    3 Pages

Archived catalogs

  1. EUROLYZER ST

    2 Pages