1. Catalogs
  2. AERSERVICE EQUIPMENTS SRL
  3. wall mounted filter with one or two extraction arms
video corpo

wall mounted filter with one or two extraction arms

wall mounted filter with one or two extraction arms
1 / 16 PagesView full catalog

wall mounted filter with one or two extraction arms

Product catalog summary
Overview
Aerservice specializes in air filtration solutions for occasional and non-intensive industrial processes, prioritizing operator safety and adherence to national and international standards. Their solutions include mechanical and electrostatic air cleaners designed to capture harmful fumes and particulates directly at the source.
Specifications
The suspended modules are tailored for single workstations and light-duty applications, featuring a multi-stage filter section with activated carbon and HEPA filters for high filtration efficiency and durability. These units comply with standards such as the Italian decree D.Lgs. 81/2008 and ACGIH guidelines.
Technology and Safety
The technology ensures pollutant capture speed is maintained at a minimum of 0.5 m/sec, meeting regulatory requirements. Filtration performance aligns with international standards to limit airborne pollutants, safeguarding worker health.
Environmental and Operational Aspects
The units are designed to optimize space usage while maximizing performance, offering a high quality-price ratio. They feature low power consumption and operate quietly. Regular maintenance and filter cleaning are recommended to sustain efficiency.
Product Features
Models like ICAP and ECOP include high-efficiency suction fans, multi-stage filtration, and optional HEPA filters for controlled environments. They are designed for easy installation and maintenance, using lightweight materials and incorporating noise reduction features.
Limitations
The modules are intended for occasional welding fume extraction and are unsuitable for dust or liquid aspiration, which could lead to equipment malfunctions.
Technical Data
The document provides detailed technical specifications for various models, including airflow capacity, filtration efficiency, and power requirements. Filters are certified to standards such as CEN 779 and EN 1822, ensuring high filtration efficiency.
Procedures
Testing procedures include visual inspections, functional tests, and electrical tests conducted in laboratories to ensure quality. The document emphasizes maintaining prescribed air intake velocities.
Norms and Certifications
Filters are tested and certified according to CEN 779, EUROVENT 4/4, and CEN EN 1822 standards, with all technical data validated by relevant authorities or partner laboratories.
Recommendations
Lightweight materials are recommended for easy installation, and maintaining optimal air flow and filtration surface area ratios is crucial for efficiency. Regular checks using differential pressure gauges are advised to monitor filter conditions.
Additional Features
Systems include features like halogen lamp light fixtures, flexible arms, and adapters for flexible hoses. ECOP models are noted for their space-efficient design and high performance, suitable for oil-laden fume filtration.
Specifications and Features
The document details a filtration system with an Automatic Filter Control (A.F.C.) system for managing electrostatic filter status and a multi-stage filtration process to prevent metal particulate ingress. It includes a droplet separator for enhanced performance in severe conditions and a continuous discharge hopper for oil recovery.
Filter Section and Certifications
The unit operates on a single-phase 230 V 50-60 Hz power supply. All filters are tested and certified according to CEN 779, EUROVENT 4/4, and CEN EN 1822 standards, achieving an efficiency of H10* 99.99% for particles less than 0.3 µm.
Metallic Filtering Cells
Metallic filtering cells, series F 13 ZMA, are designed for industrial applications, featuring a galvanized steel frame and a flat aluminum wire filter medium. They are suitable for aggressive atmospheres, anti-spark filtration, and oil fog separation.
Accessories
Accessories include a halogen lamp light fixture, activated carbon filter for adsorption and deodorization, IBS articulated arm, IBF flexible arm, and an adapter for flexible hose, enhancing the system's functionality and adaptability.
Replacement Parts
The document details replacement parts for ECOP and ECOPN models, including various filter types categorized by type, thickness, efficiency, and penetration, ensuring optimal performance and compliance with industry standards.
See more

Catalog excerpts

wall mounted filter with one or two extraction arms-1

60 1 AERSERVICE FORNISCE PRODOTTI E SOLUZIONI TENENDO CONTO DI RIFERIMENTI NORMATIVI NAZIONALI E INTERNAZIONALI TURNING SHOP 3 WELDING AND FINISHING AREA APPLICATIONS Suspended modules are designed and built for extremely occasional and non intensive work processes. The proposed solution is a mechanical or electrostatic air cleaner, which can solve the majority of problems deriving from work processes that generate both dry and oil impregnated fumes and, in certain specific cases, also oil mist. Coupling the filtration unit to a suction arm (our IBS series) makes it possible to capture, at source, fumes, gas, microscopic particulate that are harmful for operator health, and is recognised and approved by international institutions responsible for promoting and regulating health and safety in the workplace. These units are suitable exclusively for single work stations and, thanks to their excellent quality-price ratio, they constitute the ideal solution for occasional and light duty applications involving the generation of fumes that are potentially harmful for operator health. In the case of replenishment of filtered air, we recommend frequent servicing and cleaning of the filter sections to obtain higher efficiency levels and maintain filtration capacity. AERSERVICE SUPPLIES PRODUCTS AND SOLUTIONS TAKING ACCOUNT OF NATIONAL AND INTERNATIONAL NORMATIVE REFERENCES OPERATOR SAFETY Pollutants deriving from industrial and small workshop processes must be captured as close as possible to the point of release and routed to the exterior of the workplace. In the case of intermittent work processes however, such pollutants can be aspirated and filtered out of the air, which is subsequently returned to the workplace. In this case, in addition to the use of portable air cleaner systems the installation of ambient ventilation systems may be required. Italian decree D.Lgs. 81/2008 - 2006/15/EC TECHNOLOGY EMPLOYED To guarantee and satisfy the applicable national and international standards and regulations, we make use of the best available technology, which, combined with superior technical know-how, results in the creation of safe products that are in compliance with the people responsible for using the equipment; for example, the speed of capture of the pollutant is never considered at less than 0.5 m/sec during the design stage (as required by the controlling authorities). ENVIRONMENTAL ASPECT The filtration performance levels guaranteed are established in accordance with international specifications that limit the concentration levels of airborne pollutants for professional activities for which a repeatedly exposed worker does not suffer any form of health impairment. American Conference of Industrial Hygienists (ACGIH) – Italian decree D.M. 20/08/1999. National and international regulations are referred to the values specified by ACGIH.

 Open the catalog to page 1
wall mounted filter with one or two extraction arms-2

61 SUSPENDED EQUIPMENT AND DEVICES FOR EXTRACTION Equipments AND FILTRATION OF WELDING FUMES CONSTRUCTION FEATURES ICAP • Filter housing structure made of welded sheet steel with RAL 7032 grey paint finish, with welded rear bracket for wall mounting. • Suction fan collection hopper made of painted sheet steel and functioning also as a flow calming plenum to reduce the velocity of the air flowing through the filter section, increasing filter efficiency and working life. • The multi-stage filter section contains 4 different types of filter, installed in an array with the specific role of progressive...

 Open the catalog to page 2
wall mounted filter with one or two extraction arms-3

62 Facility for installation and maintenance entirely designed to involve as little space as possible while offering the highest possible level of performance. Quality - price ratio that is unparalleled by other products on the market. Low power consumption and silent running on board SUCTION fan. Multi-stage filter section, with progressively increasing efficiency, and with high filtration performance and filter working life. ICAP - ICAPTH ADDED VALUES

 Open the catalog to page 3
wall mounted filter with one or two extraction arms-4

63 Equipments PRODUCT DATA SHEET Issue PRELIMINARY POLYESTER NEEDLEFELT AREA WEIGHT g/m² DENSITY 0,32 g/cm³ THICKNESS mm PORE VOLUME 77 % FIBER POLYESTER COMPOSITION SCRIM POLYESTER FINISH HEAT SET - SURFACE GLAZING LONGITUDINAL CROSS BREAKING LOAD 720 N 750 N BREAKING ELONGATION 27 % 70 % ELONGATION at 50 N N.A. % N.A. % THERMAL STABILITY (SHRINKAGE) 2 % 1 % air at 150°C - 2 h BURST STRENGTH N.A. KPa AIR PERMEABILITY at 200 Pa l/dm² • min FIBER PROPERTIES:POLYESTER OPERATING TEMPERATURE (Dry) CONTINUOUS 150°C Max MOISTURE CONTENT0,4% PEAKS 160°C Max CHEMICAL RESISTANCE 10/08 STYLE 180 400 1,25...

 Open the catalog to page 4
wall mounted filter with one or two extraction arms-5

64 A A B C D B C D ICAP REPLACEMENT PARTS FILTER SECTION FOR ICAP FILTRATION STAGE TYPE AND NAME FILTER THICKNESS EFFICIENCY PENETRATION PFE/350 REGENERABLE PANEL PREFILTER 40 mm EU4 - G4 70% 10 P > 3 ìm PFO/PE REGENERABLE CORRUGATED PANEL FILTER 48 mm F6 85% 3 P > 1 ìm ACTIVATED CARBON FILTER 40 mm 10 Kg PF/55 HIGH EFFICIENCY PANEL FILTER 12 mm F7 90% 1 P > 0,3 ìm All filters used are tested/certified to the standards CEN 779 - EUROVENT 4/4 - CEN EN 1822

 Open the catalog to page 5
wall mounted filter with one or two extraction arms-6

65 Equipments A A B C B C ICAPTH REPLACEMENT PARTS FILTER SECTION FOR ICAPTH FILTRATION STAGE TYPE AND NAME FILTER THICKNESS EFFICIENCY PENETRATION PFO/PE REGENERABLE CORRUGATED PANEL FILTER 48 mm F6 85% 3 P > 1 ìm PF/55 HIGH EFFICIENCY PANEL FILTER 12 mm F7 90% 1 P > 0,3 ìm HEPA PANEL FILTER 68 mm H14 99,999% P < 0,3 ìm All filters used are tested/certified to the standards CEN 779 - EUROVENT 4/4 - CEN EN 1822 Efficiency H14 99,999% P<0,3 ìm

 Open the catalog to page 6
wall mounted filter with one or two extraction arms-7

66 Structure made up of lightweight materials to facilitate installation, with applied wide-section plenums for deceleration of air flow and reduced noise emissions. Latest generation electrical equipment with filter clogged indicator on electrostatic filter versions. Wide filtering section to guarantee extended lifetime of filters, as well as increased filtration and pollutant retention capacity. The ratio between air flow rate and filtration surface area is designed to guarantee optimal efficiency with continuous duty. Intake and return of the same quantity of air into the working environment,...

 Open the catalog to page 7

All AERSERVICE EQUIPMENTS SRL catalogs and technical brochures

  1. BAZ-INDUSTRY

    2  Pages

  2. BAF-INDUSTRY

    4  Pages

  3. BA-INDUSTRY

    4  Pages

  4. EC

    3  Pages

  5. CA

    3  Pages

  6. ELEMAX

    3  Pages

  7. ELE S

    2  Pages

  8. ELE F

    3  Pages

  9. AUTOMOTIVE

    10  Pages

  10. AER

    2  Pages

  11. IBF

    2  Pages

  12. AER

    6  Pages

  13. ECO

    6  Pages

  14. FACE

    6  Pages

  15. FACILE

    6  Pages