RPS-16

RPS-16

RPS-16

Product catalog summary
Overview: The document details the technical specifications and installation guidelines for RPS sanitary sampling valves, which are used for aseptic sampling of liquids and pharmaceutical products. These valves are constructed from AISI 316L stainless steel and are fully autoclavable.
Specifications:
  • Material: The valve body and shaft are made of AISI 316L. O-rings and plugs are available in standard silicone, with optional materials including FKM, EPDM, or TFM PTFE.
  • Max Working Conditions: The valves can operate under pressures up to 10 bar and temperatures of 150°C.
  • Process Connections: The standard connection is a 1/2" BS clamp, with optional connections such as 1" BS clamp, 3/8"-1/2" gas male thread, and butt-weld.
  • Outlet Connections: The standard is a LUER SLIP joint, with options for a rubber hose or rapid connection.
Installation Guidelines:
  • Valves can be installed by welding, screwing, or clamping. The flow direction is unidirectional, and reference screws must be correctly oriented to ensure proper flow.
  • The luer outlet should be horizontal and parallel to the floor. For upward flow, reference screws should be at the bottom; for downward flow, they should be at the top.
Documentation: Each valve is traceable and comes with material test certificates (EN 10 204 3.1), compliance certificates for cGMP and FDA standards, and surface roughness tapes.
Ordering Information: The document provides a detailed guide on specifying parts, including options for seals, connection types, and execution styles.
Installation Instructions: The document outlines the installation procedures for valves, emphasizing the importance of ensuring the correct flow direction by checking the orientation of reference screws. The luer outlet must be horizontal and parallel to the floor. For upward flow, reference screws should be at the bottom, and for downward flow, they should be at the top.
Sampling Characteristics: RPS sampling valves are designed for aseptic sampling of liquids and pharmaceuticals. Made from AISI 316L, they are autoclavable and can be modified for different process connections. The design prevents bacterial deposits and allows representative sampling. The valve operates by turning a knurled ratchet.
Technical Data:
  • Materials: Valve body and shaft are AISI 316L; O-ring and plug options include silicone, FKM, EPDM, and TFMPTFE.
  • Max Working Conditions: Pressure up to 10 bar and 150°C.
  • Process Connections: Standard clamp 1/2" BS, with optional sizes and types.
  • Outlet Connections: Standard LUER SLIP joint, with optional rubber hose and rapid connection.
Flush Tank Washing Valves: The VAW aseptic valve is designed for hygienic cleaning of process tanks. It features a clean design for full drainability and reduced water and cleaning agent consumption. The valve is typically welded to the tank and can be positioned to clean various parts of the equipment.
See more

Catalog excerpts

RPS-16-2

Esecuzione H a faccia piana H execution flat face RPS-05AGPAH-XX-31A Esecuzione T con tubo di sample T execution with sampling pipe RPS-05AHZCT-XX-31A

 Open the catalog to page 2
RPS-16-3

Presa campione sanitaria Dimensioni - Esecuzione standard Overall dimensions - Standard execution Tappo in silicone Silicone cap ∅i 2.5 Foro di flussaggio - ∅3 Flushing orifice Altre lungh. a richiesta Other lenght on request Valvola chiusa - 101 Valve close Valvola aperta - 104 Valve open Butt Weld 23 Luer slip Vite di riferimento Locking screw INSTALLAZIONE In funzione del tipo di connessione, la valvola potrà essere installata con corpo a saldare, clampato o filettato. Essendo il senso del flusso unidirezionale, bisogna rispettare l'orientamento della vite di riferimento per un corretto flussaggio...

 Open the catalog to page 3
RPS-16-4

Ricambi Spare parts cod. KPS-05-VV Tampone e o-ring in FKM - siringabile Plug seal and o-ring in FKM - syringable cod. KPS-05-XX Tampone e o-ring in SILICONE - siringabile Plug seal and o-ring in SILICONE - syringable cod. KPS-05-TV Tampone in TFM PTFE e o-ring in FKM - NON siringabile Plug seal in TFM PTFE and o-ring in FKM - NOT syringable To specify the part completely, start with the product description and select the additional options as shown below: H flat face T deep tube ZC luer slip XX PA rubber hose VV ZG quick connection TV AG 1/2” clamp AJ 1” clamp QC butt weld RPS LC 1/4”...

 Open the catalog to page 4
RPS-16-5

Sanitary sampling valves CHARACTERISTICS The RPS fully autoclavable sampling valves are designed for aseptic sampling of liquids and pharmaceutical products. Campionamento standard. Standard Sampling Made entirely in AISI 316L, the standard version is in the form of a rod with a 1/2" clamp and no welding. On request, the connection to the process may be modified as indicated. Easily installed onto distribution lines or onto tanks, this valve can be kept in aseptic conditions between one sample and another by using a silicon cap which closes the "luer slip" outlet. It's special design prevents...

 Open the catalog to page 5
RPS-16-6

ASEPTIC SAMPLING VALVES SANITARY SAMPLING VALVES SANITARY SAMPLING BOTTLE TANK BOTTOM ASEPTIC VALVE SPRING CHECK VALVES HIGH PURITY BALL VALVES BUTTERFLY VALVES SIGH GLASS-FLOW INDICATOR CLAMP FITTINGS TANK CONNECTIONS SILICONE HOSE & FITTINGS MAGNETIC MIXER DIAPHRAGM VALVES WASHING DEVICES AERRE INOX s.r.l. Via Gerola, 4 I-26010 Fiesco (Cremona) Tel. +39 0374 370 828 Fax +39 0374 370 833 www.aerreinox.it Get the information you need and more at [email protected]

 Open the catalog to page 6
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.