TDS ACE VII ZERO LOSS
20Pages

{{requestButtons}}

Catalog excerpts

TDS ACE VII ZERO LOSS - 1

Technical Data Sheet BOOSTER LINE ACE VII ZERO LOSS ELECTRIC

Open the catalog to page 1
TDS ACE VII ZERO LOSS - 2

Technical Data Sheet Big performance, small consumption

Open the catalog to page 2
TDS ACE VII ZERO LOSS - 3

Technical Data Sheet Technical data Type of gas Air - Helium - Nitrogen - Argon Intake pressure Nominal pressure Working pressure Permissible ambient temperature range Permissible altitude Operating voltage, standard Other operating voltage Steel - Colour Black RAL 9005 Powder coating painting - Scratch proof Compressor Flow rate Purification System 2 Hyperfilter with activated carbon 1.960 m3/h 1 Standard model. Dimensions and weight may vary depending on accessories. Electric motor Power Three-phase electric Operating voltage/frequency Different voltage / frequency available on request....

Open the catalog to page 3
TDS ACE VII ZERO LOSS - 4

Technical Data Sheet

Open the catalog to page 4
TDS ACE VII ZERO LOSS - 5

Technical Data Sheet Control pannel Main switch 4th stage pressure gauge/ working pressure Stop pushbutton Condensate discharge valve Condensate discharge pushbutton Purification system Power indicator light Filter cartridge Hyperfilter x nitrogen Minimum oil pressure switch Direction of rotation indicator light Electric motor Safety valve Oil level warning light Electrical cabinet Maintenance valve pressure Hour meter Pumping unit Control Panel Condensate separator Final condensate separator 1st stage pressure gauge Circuit pressure discharge valve 2nd stage pressure gauge Suction filter...

Open the catalog to page 5
TDS ACE VII ZERO LOSS - 6

Technical Data Sheet Forced lubrification with low pressure gear pump

Open the catalog to page 6
TDS ACE VII ZERO LOSS - 7

Technical Data Sheet First stage for gas recovery Pipes, fitting and nuts in stainless steel AISI 316 Intermediate condensate separator after the second and third stage Synthetic Oil Coltri ST 755 with special formulation for HP compressors Discover more on Coltri Oil ST 755

Open the catalog to page 7
TDS ACE VII ZERO LOSS - 8

Technical Data Sheet High pressure final condensate separators double effect Safety valves after each stage of compression Special cast iron cylinders with low roughness lapping Roller Bearings for intensive work Forged aluminum connecting rods Forged steel crankshaft

Open the catalog to page 8
TDS ACE VII ZERO LOSS - 9

Technical Data Sheet High-flow first, second and third stage valves Fourth stage in tempered steel with 6 piston rings in special cast iron Second and third stage with pushing pistons to eliminate lateral forces on the pistons It ensures that the compressor only works if the oil pressure, downstream of the pump, is higher than 1.5 bar.

Open the catalog to page 9
TDS ACE VII ZERO LOSS - 10

Technical Data Sheet Technical data pumping unit MCH 36 ACE VII ZERO LOSS 11 KW Intake pressure Flow rate Speed (RPM) Number of stages Cylinder bore 2nd stage Cylinder bore 3rd stage Cylinder bore 4th stage Direction of rotation from flywheel side Counter clockwise (left) Drive type

Open the catalog to page 10
TDS ACE VII ZERO LOSS - 11

Technical Data Sheet Standard equipment Purification system Hyperfilter for nitrogen DOUBLE HYPERFILTER regenerable or disposable cartridge Hyperfilter body Cartridge spring Hyperfilter cartridge Stainless hook Felt disc Purification system Operating pressure (Standard) Filtered gas volume (nitrogen) When using a filter cartridge of the type shown in the figure.

Open the catalog to page 11
TDS ACE VII ZERO LOSS - 12

Technical Data Sheet Stand-alone kit with Hyperfilter Purification system Pressure gauge Safety valve Condensate separator Manual filter discharge Automatic condensate drain for external separator* Stainless steel frame with provision for wall mounting

Open the catalog to page 12
TDS ACE VII ZERO LOSS - 13

Technical Data Sheet

Open the catalog to page 13
TDS ACE VII ZERO LOSS - 14

Technical Data Sheet Additional purification system with Hyperfilter Safety valve (variable according to customer request) Pressure maintenance valve External Hyperfilter separator and filters kit Ground or stand-alone stainless steel support Automatic condensate drain High pressure final condensate separator double effect The automatic condensate drain removes water from the intermediate separator and the final separator automatically during operation (every 7 minutes). Consists of: 1 x solenoid valve

Open the catalog to page 14
TDS ACE VII ZERO LOSS - 15

Technical Data Sheet Condensate separation system • Interstage separator after 2nd stage, forged and anodized aluminum • Double final separator for removal of oil/water condensate • Final safety valve, mounted on the separator housing • Pressure maintenance valve / non-return valve * Measured at our facility using ASCO HORA 160 ANALYZER. 1 The level of CO2 in the intake air must not exceed the maximum level of CO2 as per EN 12021:2014 2 Reported values exceed ISO 8573-1 standards.

Open the catalog to page 15
TDS ACE VII ZERO LOSS - 16

Technical Data Sheet Compressor control and automatic condensate drain system • Motor protection switch. • Pressure switch with fixed setting 232 or 300 bar. • Autostart with pressure differential 15 bar (optional). • Transformer. • Drainage of all separators between the individual stages and also of the final separator during compressor operation (standard drain interval every 15 minutes for a period of 6 seconds). • Timer for automatic condensate drainage device. • Interstage pressure gauges display the operating pressure for the individual compression stages. This pressure information...

Open the catalog to page 16
TDS ACE VII ZERO LOSS - 17

Technical Data Sheet Plugs available according to electric motor 230 V three-phase electric motor 9h/200 - 250V~ 50÷60 Hz 32 A 3P+ 400 V three-phase electric motor 6h/380 - 415V~ 50÷60 Hz 16 A 3P+ 400 V three-phase electric motor 6h/200/346 - 240/415V~ 50÷60 Hz 32 A 3P+N+

Open the catalog to page 17
TDS ACE VII ZERO LOSS - 18

Technical Data Sheet Data sheet three-phase electric motor 11 kW SPECIFICA TECNICA MOTORE EL. Electric motor technical data sheet No Descrizione/Description 1 Codice Soga / ref.code Descrizione / Description Carcassa motore / Framesize Forma di costruzione / Mounting type Potenza nominale / Rated output Tipo di servizio / Duty type Fattore di potenza / Power factor Coppia nominale motore/ Rated motor torque Tensione / Rated voltage Frequenza / Rated frequency Corrente nominale / Rated current Velocità nominale / Rated speed Corrente avviamento / Corrente nominale Starting current / Rated...

Open the catalog to page 18
TDS ACE VII ZERO LOSS - 19

Technical Data Sheet Data sheet three-phase electric motor 15 kW SPECIFICA TECNICA MOTORE EL. Electric motor technical data sheet No Descrizione/Description 1 Codice Soga / ref.code Descrizione / Description Carcassa motore / Framesize Forma di costruzione / Mounting type Potenza nominale / Rated output Tipo di servizio / Duty type Fattore di potenza / Power factor Coppia nominale motore/ Rated motor torque Tensione / Rated voltage Frequenza / Rated frequency Corrente nominale / Rated current Velocità nominale / Rated speed Corrente avviamento / Corrente nominale Starting current / Rated...

Open the catalog to page 19

All AEROTECNICA COLTRI S.p.A. catalogs and technical brochures

  1. CNG EVO