video corpo

Protect 8 S14

Protect 8 S14

Protect 8 S14

Product catalog summary
Specifications:
The Protect 8 S14 is an industrial-grade monoblock UPS designed for harsh environments. It supports input and output voltages of 380/400/415 VAC for 3-phase and 220/230/240 VAC for 1-phase configurations. It features a compact design, high overload capacity, and high efficiency even at low output power. The UPS is user-friendly, easy to maintain, and offers a lifespan of over 20 years. It is robust, reliable, and suitable for environments with high humidity and temperatures, operating up to 4000 meters above sea level. The system supports redundant parallel operation of up to 8 UPS units and provides isolated output voltage with a fully redundant control architecture.
Features:
The Protect 8 S14 includes a state-of-the-art double-conversion topology, ensuring flexibility and suitability for demanding applications. It meets EMC and international standards, offering a cost-effective solution with minimal operating costs. The UPS is designed for critical load operations, ensuring reliability, availability, and maintainability.
Typical Applications:
The UPS is ideal for industrial applications such as oil & gas, petrochemical, energy and power, transportation, water treatment, instrumentation, process control, and various industrial production processes.
Benefits:
The Protect 8 S14 offers high efficiency, a small footprint, versatile communication capabilities, and intelligent battery charge and monitoring control. It supports lithium-ion battery charging options and has a large battery voltage range.
Technical Data:
  • Rectifier Unit: Nominal DC voltage of 384 V, input frequency range of 50/60 Hz ±10%, and input current at nominal load of 17 – 195 A.
  • Inverter Unit: DC input of 384 V ±20%, with nominal power ranging from 10 – 120 kVA for 3-phase and 10 – 60 kVA for 1-phase configurations.
  • Static Bypass Switch: Nominal AC voltage of 3 x 400 V for 3-phase and 230 V for 1-phase, with a nominal frequency of 50/60 Hz.
  • General Data: Efficiency up to 94% or >95% with ECO Mode, noise level <62 – 70 dB (A), operation temperature from -10 °C to 40 °C, and maximum altitude of 1000 m without derating.
Standards:
The UPS complies with IEC 62040-1 for safety, IEC 62040-2 for EMC immunity and emission, and IEC 62040-3 for performance. It also adheres to RoHS and WEEE environmental standards and carries CE marking.
See more

Catalog excerpts

Protect 8 S14-1

POWER SOLUTIONS industrial UPS with compact design The state-of-the-art, double-conversion topology and design of the Protect 8 UPS series is flexible and can meet practically all customer requirements. The system is suitable for use in harsh environments. Protect 8 S14 is a robust and easy to operate UPS, meeting the relevant EMC and other international standards. With an expected lifetime of at least 20 years, the Protect 8 S14 is a rugged and cost-effective solution optimized for minimal operating costs. Designed for highly demanding applications, the Protect 8 S14 will ensure safe operation of all types of critical loads, delivering total control wherever reliability, availability and maintainability are required. Typical applications For all industrial applications • Oil & Gas, Petrochemical (offshore, onshore, pipelines) • Energy and Power (generation, transmission, distribution) • Transportation (rail, airports, shipping, highways, tunnels) • Water (desalination, treatment) • Instrumentation & Process control (chemicals, mining, steel, paper, emergency lightning) • All industrial production processes • Without input transformer - unique solution available on the market • Dedicated to very harsh environments • Compact design with small foot print • High overload capacity • High efficiency even at low output power • User friendly, easy to operate, easy to maintain • Easy service for more than 20 years of life span • Robust and reliable solution suitable for stringent seismic spectrum • High humidity level and temperature range, able to operate up to 4000 m above

 Open the catalog to page 1
Protect 8 S14-2

Specifications RECTIFIER UNIT Nominal DC voltage Nominal AC voltage Input frequency range Operation range (min./max.) Input current at nominal load Rectifier type ––Standard ––Option INVERTER UNIT DC Input @3 phase output voltage configuration ––Nominal AC voltage ––Nominal output current ––Nominal power @1 phase output voltage configuration ––Nominal AC voltage ––Nominal output current ––Nominal power Output voltage static stability Output voltage dynamic response Recovery time Frequency Frequency static stability (on internal clock) Frequency synchronization range Power factor at nominal load...