Applications
Inductive sensors are extensively used in environments with oil, dust, liquids, and vibrations. They are integral to machine tools, textile machines, transfer lines, transport systems, packaging equipment, and the automotive industry for automation solutions.
Standardized Sensing Plate
The standardized sensing plate, as per European standard EN60947-5-2, is a square steel plate, 1 mm thick, matching the sensor's active surface diameter. Larger plates do not enhance the nominal intervention distance, while smaller ones reduce it.
Intervention Distances
  • Nominal Intervention Distance (Sn): The switching value without temperature and voltage variations.
  • Real Intervention Distance (Sr): Measured at nominal conditions, with 0.9Sn ≤ Sr ≤ 1.1Sn.
  • Useful Intervention Distance (Su): Measured within specified limits, with 0.9Sr ≤ Su ≤ 1.1Sr.
Tightening Torques
Ensure not to exceed specified tightening torques during installation to prevent mechanical damage.
Working Principle
Inductive sensors generate an alternating inductive field that changes when a metallic object enters, altering the oscillator state and controlling an external load. The intervention distance varies with metal type. Sensors are protected against polarity inversion and electrical disturbances, with short circuit protection in DC versions.
Sensor Versions
  • Version N: Non-amplified DC sensors for electronic amplified threshold circuits, with ATEX approval.
  • Version B: Two-wire amplified DC sensors for programmable controllers.
  • Version C: Three or four-wire amplified DC sensors, protected against short circuits and polarity inversion.
  • Version A: Two-wire AC sensors with thyristor output amplifier, compatible with PLC units.
Power Supply Suggestions
Adjust supply voltage according to sensor characteristics, using a transformer with secondary voltage lower than required direct voltage. Filter supply voltage with at least 470 µF per 200 mA used. Use a voltage stabilizer for high supply voltage.
Technical Specifications
The document covers models like SIPA8, SIPC8, SIP10, SIP12, SIP17, SIP25, SIP40, and SIQ80, available in 2-wire AC, 3-wire DC, and 4-wire DC versions. Key specifications include adjustable switching distance, continuous voltage range of 6-60V, switching frequency up to 2000 Hz, temperature limits from -25°C to +70°C, and IP ratings from IP65 to IP67. Housing materials include anodized aluminum, plastic, or nickelled brass.
Installation and Connection
Sensors connect via PVC cables or connector plugs (M8, M12). Installation requires maintaining distance from metallic objects to avoid interference and ensuring proper alignment for optimal performance.
Operational Guidelines
Sensors are suitable for detecting, counting, and controlling small metallic parts. They can be paired with a programmable amplifier (ALTP series) for fast-moving object detection. Avoid interference from surrounding metals and ensure proper spacing between objects in the detection area.
Additional Features
Some models offer programmable features and adjustable sensitivity for customization. Sensors support both flush and non-flush mounting, providing installation flexibility.
See more

Catalog excerpts

INDUCTIVE SENSORS-1

SENSORI INDUTTIVI INDUCTIVE SENSORS

 Open the catalog to page 1
INDUCTIVE SENSORS-2

SENSORI INDUTTIVI SERIE SI INDUCTIVE SENSORS SI SERIES I sensori induttivi trovano largo impiego in ogni tipo di applicazione e nelle condizioni più gravose come in presenza di olio, polvere, liquidi in genere e vibrazioni che non condizionano la loro precisione ed il sicuro funzionamento. I sensori AECO sono applicati su macchine utensili ed operatrici, macchine tessili, linee transfer, impianti di trasporto, macchine per il confezionamento, nell’industria automobilistica e per la soluzione di tutti i problemi connessi con l’automazione. Inductive sensors have wide uses in many applications,...

 Open the catalog to page 2
INDUCTIVE SENSORS-3

SENSORI INDUTTIVI SERIE SI INDUCTIVE SENSORS SI SERIES SENSORI IN ESECUZIONE N CONFORMI NORME NAMUR EN 60947-5-6 SENSOR VERSION N IN ACCORDANCE WITH NAMUR STANDARDS EN 60947-5-6 Sono sensori non amplificati in corrente continua a due fili che contengono il solo oscillatore e sono adatti a pilotare un circuito elettronico amplificatore a soglia. Necessitano di pochi elementi costruttivi e pertanto offrono la massima sicurezza di esercizio. Grazie alla bassa resistenza Ohmica di chiusura il sensore è insensibile alle dispersioni induttive o capacitive presenti sulla linea di collegamento con l’amplificatore...

 Open the catalog to page 3
INDUCTIVE SENSORS-4

SUGGESTIONS FOR SUPPLYING VOLTAGE TO INDUCTIVE SENSORS ALIMENTAZIONE DI SENSORI INDUTTIVI IN CORRENTE CONTINUA ESEMPIO A / EXAMPLE A ESEMPIO B / EXAMPLE B Stabilizzatore Voltage stabilizer La tensione di alimentazione deve essere adeguata alle caratteristiche dei dispositivi usati. Usare sempre trasformatori con tensione di secondario Vca inferiore alla tensione continua desiderata Vcc. La tensione Vca di secondario da utilizzare si ricava così: Vca = (Vcc + 1) : 1,41 Inoltre la tensione continua Vcc di alimentazione dei dispositivi deve essere filtrata con una capacità C di almeno 470 µF per...

 Open the catalog to page 4
INDUCTIVE SENSORS-5

MODELLI MODELS CILINDRICI PARZIALMENTE SCHERMATI NOT EMBEDDABLE CYLINDRICAL MODELS B PARZIALMENTE SCHERMATI NOT EMBEDDABLE (NON FLUSH MOUNTING) TOTALMENTE SCHERMATI EMBEDDABLE (FLUSH MOUNTING) CILINDRICI TOTALMENTE SCHERMATI EMBEDDABLE CYLINDRICAL MODELS A = Mutua interferenza - B = Influenza con parti metalliche A = Mutual interference - B = Interference with metallic part * = Modelli con portata maggiorata * = Models with extended switching distance A • Gli esempi di installazione sono riferiti alla superficie attiva contrassegnata in giallo. • The installation example makes reference to the...

 Open the catalog to page 5
INDUCTIVE SENSORS-6

SENSORI INDUTTIVI NAMUR • NAMUR INDUCTIVE SENSORS • CUSTODIA CILINDRICA Ø 6.5 - M8-M12-M14-M18-M30 2 FILI C.C. - ESECUZIONE-N • CYLINDRICAL HOUSING Ø 6.5 - M8-M12-M14-M18-M30 2 WIRES D.C. - VERSION-N Ø 6,5 TOTALMENTE SCHERMATI EMBEDDABLE (FLUSH MOUNTING) PARZIALMENTE SCHERMATI NOT EMBEDDABLE (NON FLUSH MOUNTING) CARATTERISTICHE TECNICHE TECHNICAL CHARACTERISTICS Dimensioni / Dimensions MODELLI CON CAVO MODELS WITH CABLE ATEX NAMUR nsors.com cose www.ae Distanza di intervento Sn Switching distance Sn Tensione continua (ond. residua ≤ 10%) Continuous voltage (residual ripple ≤10%) MODELLI CON CONNETTORE...

 Open the catalog to page 6
INDUCTIVE SENSORS-7

SENSORI INDUTTIVI NAMUR • NAMUR INDUCTIVE SENSORS • CONFORMI ALLE NORME NAMUR EN 60947-5-6 • CONFORMING TO NAMUR STANDARDS EN 60947-5-6 M14 x 1 8,2 ("5 ÷ 30" vedi nota 1 a pag. 7) 8,2 ("5 ÷ 30" see note 1 at page 7) In presenza di metallo ≤ 1 mA - In assenza di metallo ≥ 3 mA In presence of metal ≤ 1 mA - In absence of metal ≥ 3 mA 2000 ≤3 -25 ÷ +70 67 (Con attacco H in funzione del connettore) 67 (With H depending on connector) Ottone nichelato Nickelled brass 2 x 0.25 mm2 Non previsto Not foreseen Vedi pag. 7 / See page 7 Vedi pag. 8 - fig. 2 / See page 8 - pict. 2 Vedi pag. 9 / See page 9...

 Open the catalog to page 7
INDUCTIVE SENSORS-8

SENSORI INDUTTIVI NAMUR • NAMUR INDUCTIVE SENSORS • CUSTODIA RETTANGOLARE SIPA8 - SIPC8 - SIP10 - SIP12 - SIP17 - SIP40 - SIQ80 2 FILI C.C. - ESECUZIONE-N • RECTANGULAR HOUSING SIPA8 - SIPC8 - SIP10 - SIP12 - SIP17 - SIP40 - SIQ80 2 WIRES D.C. - VERSION-N PORTATA STANDARD STANDARD SWITCHING DISTANCE Zona sensibile / Sensing surface Zona sensibile / Sensing surface Zona sensibile / Sensing surface TOTALMENTE SCHERMATI EMBEDDABLE (FLUSH MOUNTING) PARZIALMENTE SCHERMATI NOT EMBEDDABLE (NON FLUSH MOUNTING) CARATTERISTICHE TECNICHE TECHNICAL CHARACTERISTICS Dimensioni / Dimensions MODELLI CON CAVO...

 Open the catalog to page 8
INDUCTIVE SENSORS-9

SENSORI INDUTTIVI NAMUR • NAMUR INDUCTIVE SENSORS • CONFORMI ALLE NORME NAMUR EN 60947-5-6 • CONFORMING TO NAMUR STANDARDS EN 60947-5-6 Zona sensibile Sensing surface Zona sensibile Sensing surface Sensibilità orientabile in 5 posizioni Sensitivity adjustable in 5 positions Zona sensibile Sensing surface Zona sensibile Sensing surface Sensibilità orientabile in 5 posizioni Sensitivity adjustable in 5 positions 8,2 ("5 ÷ 30" vedi nota 1 a pag. 7) 8,2 ("5 ÷ 30" see note 1 at page 7) In presenza di metallo ≤ 1 mA - In assenza di metallo ≥ 3 mA In presence of metal ≤ 1 mA - In absence of metal ≥...

 Open the catalog to page 9
INDUCTIVE SENSORS-10

SENSORI INDUTTIVI Ø 4mm• INDUCTIVE SENSORS Ø 4mm • CUSTODIA CILINDRICA - 3 FILI IN C.C. - ESECUZIONE-C • CYLINDRICAL HOUSING - 3 WIRES D.C. - VERSION-C PORTATA STANDARD STANDARD SWITCHING DISTANCE PORTATA MAGGIORATA EXTENDED SWITCHING DISTANCE TOTALMENTE SCHERMATI EMBEDDABLE (FLUSH MOUNTING) CARATTERISTICHE TECNICHE TECHNICAL CHARACTERISTICS Dimensioni / Dimensions AMPLIFICATI 3 FILI C.C. AMPLIFIED 3 WIRES D.C. Tensione continua (ond. residua ≤ 10%) Continuous voltage (residual ripple ≤10%) Isteresi Hysteresis Distanza di intervento Sn Switching distance Sn Corrente max di uscita Max output current...

 Open the catalog to page 10
INDUCTIVE SENSORS-11

SENSORI INDUTTIVI M5 x 0,5 • INDUCTIVE SENSORS M5 x 0,5 • CUSTODIA CILINDRICA - 3 FILI IN C.C. - ESECUZIONE-C • CYLINDRICAL HOUSING - 3 WIRES D.C. - VERSION-C 6 ÷ 30 < 10 2000 ≤3 150 < 10 < 1,4 Presente Incorporated Presente Incorporated - 25 ÷ + 70 In funzione del connettore Depending on connector 67 Acciaio inox Stainless steel 3 x 0.14 mm2 H1 (M8) Vedi pag. 7 / See page 7 Vedi pag. 8 - fig. 4 / See page 8 - pict. 4

 Open the catalog to page 11
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.