SENSORI INDUTTIVI INDUCTIVE SENSORS SENSORI INDUTTIVI SERIE ATEX INDUCTIVE SENSORS ATEX SERIES
Open the catalog to page 1CYLINDRICAL HOUSING 6,5 Dia. - M8-M12-M14-M1-M30 2 WIRES D.C. - VERSION -N CONFORMING: - Directive ATEX 94/9/CE Group “II” Category “1” Gas “G”(Zone 0) and Dust “D”(Zone 20) (Reference standards: EN60079-0:2012, EN60079-11:2012 and EN60079-26:2007) - International Scheme IECEx type of protection “Ex ia” (Reference standards: IEC60079-0:2011, IEC60079-11:2011 and IEC60079-26:2006) - Directive Electromagnetic Compatibility 2004/108/CE - Product standard EN60947-5-6 A EMBEDDABLE (FLUSH MOUNTING) • NOT EMBEDDABLE (NON FLUSH MOUNTING) TECHNICAL CHARACTERISTICS Dimensions in mm MODELS WITH CABLE...
Open the catalog to page 2NAMUR INDUCTIVE SENSORS ATEX/IECEx APPROVALS: EC- Tipe Examination Certificate - ATEX n° IMQ 13 ATEX 019 Certificate of Conformity IECEx n° IECEx IMQ 13.0012X Notification of production quality assurance: CESI 04 ATEX 132 Q 8,2 In presence of metal < 1 mA - In absence of metal >3 mA | 1000 | < 3 -20 - +60 IP67 with cable - IP66 or IP67 H/H1 plug (Depending on connector) Nickelled brass The NAMUR ATEX/IECEx series inductive sensors are electronic proximity sensors whose input current is changed with the approach of a metal actuator (see figs. 1,2 and 3). The small size, low current, voltage...
Open the catalog to page 3RECTANGULAR HOUSING SIPA8 - SIPC8 - SIP10 - SIP12 - SIP40 - SIQ80 2 WIRES D.C. - VERSION-N CONFORMING: - Directive ATEX 94/9/CE Group “II” Category “1” Gas “G”(Zone 0) and Dust “D”(Zone 20) (Reference standards: EN60079-0:2012, EN60079-11:2012 and EN60079-26:2007) - International Scheme IECEx type of protection “Ex ia” (Reference standards: IEC60079-0:2011, IEC60079-11:2011 and IEC60079-26:2006) - Directive Electromagnetic Compatibility 2004/108/CE - Product standard EN60947-5-6 ^ EMBEDDABLE (FLUSH MOUNTING) • NOT EMBEDDABLE (NON FLUSH MOUNTING) MODELS WITH CONNECTOR SIPA8-N1.5 HI AGD1...
Open the catalog to page 4NAMUR INDUCTIVE SENSOR ATEX/IECEx APPROVALS: EC- Tipe Examination Certificate - ATEX n° IMQ 13 ATEX 019 Certificate of Conformity IECEx n° IECEx IMQ 13.0012X Notification of production quality assurance: CESI 04 ATEX 132 Q In presence of metal <1 mA - In absence of metal >3 mA 2000 | 2000 500 < 3 -20 - +60 IP67 with cable - IP66 or IP67 H/H1 plug (Depending on connector) | IP67 with cable with plug IP66 N.B. A = Mutual interference - B = Interference with metallic parts
Open the catalog to page 5NAMUR INDUCTIVE SENSORS ATEX/IECEx RING HOUSING SIA05 - SIA12 - SIA15 - SIA22 - SIA30 - SIA44 - SIA63 2 WIRES D.C. - VERSION - N CONFORMING: - Directive ATEX 94/9/CE Group “II” Category “1” Gas “G”(Zone 0) and Dust “D”(Zone 20) (Reference standards: EN60079-0:2012, EN60079-11:2012 and EN60079-26:2007) - International Scheme IECEx type of protection “Ex ia” (Reference standards: IEC60079-0:2011, IEC60079-11:2011 and IEC60079-26:2006) - Directive Electromagnetic Compatibility 2004/108/CE - Product standard EN60947-5-6 • NOT EMBEDDABLE (NON FLUSH MOUNTING) TECHNICAL CHARACTERISTICS MODELS WITH...
Open the catalog to page 6NAMUR INDUCTIVE SENSORS ATEX/IECEx APPROVALS: EC- Tipe examination certificate - ATEX n° IMQ 13 ATEX 019 Certificate of Conformity IECEx n° IECEx IMQ 13.0012X Notification of production quality assurance: CESI 04 ATEX 132 Q 8,2 In presence of metal <1 mA - In absence of metal >3 mA 600 - 1000 | 600- 800 | 250 - 600 | 100- 200< 0.3 -20 - +60 IP67 with cable - IP66 or IP67 H/H1 plug (Depending on connector)Plastic SELECTION OF RING SENSOR Selection should be made based on the minimum hole diameter required. In this way the sensitivity adjustment can be made within normal parameters and need...
Open the catalog to page 7NAMUR INDUCTIVE SENSORS ATEX/IECEx CONNECTION TO INTRINSICALLY SAFE CIRCUITS The NAMUR series inductive sensors must always be connected to associated equipment with intrinsically safe electronic circuits with an EC Type examination certificate/certificate of conformity (CoG) with the following safety parameters: Where: Vo = Maximum open circuit voltage at the terminals of the intrinsically safe circuit of the associated device. Io = Maximum current that may be taken from the ends of the intrinsically safe circuit of the associated device Po = Maximum power that can be supplied by an...
Open the catalog to page 8La riproduzione del presente catalogo è VIETATA, la Società AECO si riserva di apportare alle proprie apparecchiature le modifiche necessarie, senza preavviso in qualsiasi momento. Reproduction of this catalog is PROHIBITED, the AECO Company reserves the right to make any necessary changes to its equipment without notice at any time. AECO s.r.l. Via G. Leopardi, 5 - 20065 Inzago (Milano) ITALY Tel. ++39 02 954381 - Fax ++39 02 9548528 email: mv.italy@aecosensors.com email: mv.export@aecosensors.com www.aecosensors.com
Open the catalog to page 10All AECO catalogs and technical brochures
-
Catalogue 2018
160 Pages
-
General Catalogue 2016
148 Pages
-
General catalogue
152 Pages
-
AMPLIFIERS FOR SENSORS
4 Pages
-
CONNECTORS
4 Pages
-
REFLECTORS
4 Pages
-
PROXY TESTER
4 Pages
-
SEQUENCE TIMERS
4 Pages
-
POWER SUPPLIES FOR SENSORS
4 Pages
-
INTRINSIC SAFETY ATEX BARRIERS
24 Pages
-
MEMBRANE LEVEL CONTROLS
4 Pages
-
ROTATIVE LEVEL CONTROLS
4 Pages
-
CONDUCTIVITY LEVEL CONTROLS
8 Pages
-
CAPACITIVE LEVEL CONTROLS
20 Pages
-
MAGNETIC REED SENSORS
8 Pages
-
ultrasonic sensors
22 Pages
-
fiber optic SeNSorS
8 Pages
-
PhOTOElECTRIC SENSORS
18 Pages
-
CAPACITIVE SENSORS
18 Pages
-
INDUCTIVE SENSORS
62 Pages
-
CAPACITIVE SENSORS
16 Pages
-
PHOTOELECTRIC SENSORS
22 Pages
-
INDUCTIVE SENSORS
60 Pages
-
LEVEL CONTROLS
12 Pages
-
MAGNETIC SENSORS
6 Pages
-
ROTATION CONTROLS
6 Pages
-
ULTRASONIC SENSORS
2 Pages