Material Handling | Process Cooling | Temperature Control | Size Reduction Technical Data Sheet PS Series Air-Cooled Packaged Chillers provide 2.0 to 3.5 hp cooling capacities with very compact footprints. These chillers feature a unique enclosure design that simplifies service and maintenance and conserves valuable production floor space. Incorporate these chillers into your planned or existing production layout easily and effectively. All PS Series Packaged Chillers have an operating leaving water temperature range of 30°F to 65°F (-1°C to 18°C). Standard Features • Operating leaving water temperature range 30°F to 65°F (-1°C to 18°C) • Hot gas bypass capacity control • Scroll compressor • R-410a refrigerant • External fill/drain/sight glass • Valved Process water connections • Low Process water pressure switch • Non-ferrous piping • Hot gas bypass capacity control • Scroll compressor • Pressure-actuated Process water bypass valve for system protection • To Process 2.5" dual scale liquid-filled pressure gauge • Fully insulated refrigeration and process piping • High and low refrigerant pressure cut-outs • High compressor discharge temperature cut-out • High pressure spring-actuated refrigerant relief valve • Filter dryer, sight glass, balanced-port thermal expansion valve, refrigeration service access ports Electrical Control Features • Fully accessible NEMA 12 enclosure • Non-fused disconnect switch with MCP motor protection • Microprocessor-based PID auto-tuning controller with To Process and Set Point LED readout • Low and high process water temperature electronic cut-out switch with LCD display • Graphic control panel with status lights Optional Features • 380/3/50 or 575/3/60 operating voltage • Automatic water makeup valve • Process water sidestream 50p filter w/ flowmeter • Audible and visual alarm for high and low water temperature, low water flow, and high and low refrigerant pressure • Compressor hour meter • RS232 or RS485 communications • UL-Labeled electrical subpanel • NEMA-12 control access window ACS Group | 2900 South 160th Street, New Berlin, WI 53151 | P: 1.262.641.8600 E: [email protected] W:
Open the catalog to page 1PS SERIES Product Diagrams Specifications Model NOTE: Nominal operating parameters for SMC air-cooled chillers are 50OF leaving water temperature at 2.4 gpm/ton, with 95OF ambient air. For 50 Hz applications, multiply capacity by 0.83. Nominal 60 Hz flow rate must be maintained. 2900 South 160th Street, New Berlin, WI 53151 | P: 1.262.641.8600 E: [email protected] W: www.aecinternet.com Rev 04.14.2016
Open the catalog to page 22 Pages
2 Pages
2 Pages
12 Pages
4 Pages
2 Pages
2 Pages
2 Pages
4 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
20 Pages
4 Pages
4 Pages
2 Pages
2 Pages
8 Pages
8 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
8 Pages
16 Pages
12 Pages
8 Pages
12 Pages
12 Pages
12 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
4 Pages
2 Pages
2 Pages
2 Pages
4 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
4 Pages