1. Catalogs
  2. AEC, Inc. - ACS Group
  3. PS Series 2.0 to 3.5 hp

PS Series 2.0 to 3.5 hp

PS Series 2.0 to 3.5 hp

PS Series 2.0 to 3.5 hp

Product catalog summary
Overview: The PS Series Air-Cooled Packaged Chillers offer cooling capacities ranging from 2.0 to 3.5 hp with compact designs suitable for efficient integration into production layouts. They operate within a leaving water temperature range of 30°F to 65°F (-1°C to 18°C).
Standard Features:
  • Hot gas bypass capacity control and scroll compressor.
  • R-410a refrigerant and non-ferrous piping.
  • External fill/drain/sight glass and valved process water connections.
  • Pressure-actuated process water bypass valve for system protection.
  • Fully insulated refrigeration and process piping.
  • High and low refrigerant pressure cut-outs and high compressor discharge temperature cut-out.
  • Filter dryer, sight glass, balanced-port thermal expansion valve, and refrigeration service access ports.
Electrical Control Features:
  • Fully accessible NEMA 12 enclosure with non-fused disconnect switch and MCP motor protection.
  • Microprocessor-based PID auto-tuning controller with LED readout.
  • Low and high process water temperature electronic cut-out switch with LCD display.
  • Graphic control panel with status lights.
Optional Features:
  • Different operating voltages (380/3/50 or 575/3/60).
  • Automatic water makeup valve and process water sidestream filter with flowmeter.
  • Audible and visual alarms for various conditions.
  • Compressor hour meter and RS232 or RS485 communications.
  • UL-Labeled electrical subpanel and NEMA-12 control access window.
Specifications:
  • Models PSA 2 and PSA 3.5 feature hermetic scroll compressors and SS copper-brazed plate evaporators.
  • Aluminum fin/copper tube condensers with washable filters.
  • Reservoir capacity of 6 gallons (polyethylene) and discharge air openings at 18.5”.
  • Nominal cooling capacities of 2.2 and 3.3 tons, respectively, with specific water flow rates and electrical requirements.
Additional Notes:
  • Nominal operating parameters are based on a 50°F leaving water temperature at 2.4 gpm/ton with 95°F ambient air.
  • For 50 Hz applications, capacity should be multiplied by 0.83.
  • Optional additional process pump horsepower reduces chiller capacity by 0.2 tons per hp.
See more

Catalog excerpts

PS Series 2.0 to 3.5 hp-1

Material Handling | Process Cooling | Temperature Control | Size Reduction Technical Data Sheet PS Series Air-Cooled Packaged Chillers provide 2.0 to 3.5 hp cooling capacities with very compact footprints. These chillers feature a unique enclosure design that simplifies service and maintenance and conserves valuable production floor space. Incorporate these chillers into your planned or existing production layout easily and effectively. All PS Series Packaged Chillers have an operating leaving water temperature range of 30°F to 65°F (-1°C to 18°C). Standard Features • Operating leaving water temperature range 30°F to 65°F (-1°C to 18°C) • Hot gas bypass capacity control • Scroll compressor • R-410a refrigerant • External fill/drain/sight glass • Valved Process water connections • Low Process water pressure switch • Non-ferrous piping • Hot gas bypass capacity control • Scroll compressor • Pressure-actuated Process water bypass valve for system protection • To Process 2.5" dual scale liquid-filled pressure gauge • Fully insulated refrigeration and process piping • High and low refrigerant pressure cut-outs • High compressor discharge temperature cut-out • High pressure spring-actuated refrigerant relief valve • Filter dryer, sight glass, balanced-port thermal expansion valve, refrigeration service access ports Electrical Control Features • Fully accessible NEMA 12 enclosure • Non-fused disconnect switch with MCP motor protection • Microprocessor-based PID auto-tuning controller with To Process and Set Point LED readout • Low and high process water temperature electronic cut-out switch with LCD display • Graphic control panel with status lights Optional Features • 380/3/50 or 575/3/60 operating voltage • Automatic water makeup valve • Process water sidestream 50p filter w/ flowmeter • Audible and visual alarm for high and low water temperature, low water flow, and high and low refrigerant pressure • Compressor hour meter • RS232 or RS485 communications • UL-Labeled electrical subpanel • NEMA-12 control access window ACS Group | 2900 South 160th Street, New Berlin, WI 53151 | P: 1.262.641.8600 E: [email protected] W:

 Open the catalog to page 1
PS Series 2.0 to 3.5 hp-2

PS SERIES Product Diagrams Specifications Model NOTE: Nominal operating parameters for SMC air-cooled chillers are 50OF leaving water temperature at 2.4 gpm/ton, with 95OF ambient air. For 50 Hz applications, multiply capacity by 0.83. Nominal 60 Hz flow rate must be maintained. 2900 South 160th Street, New Berlin, WI 53151 | P: 1.262.641.8600 E: [email protected] W: www.aecinternet.com Rev 04.14.2016

 Open the catalog to page 2

All AEC, Inc. - ACS Group catalogs and technical brochures

  1. T50-Series

    2  Pages

  2. AF1000 Series

    2  Pages

  3. 30RB Series

    2  Pages

  4. AF Series

    2  Pages

  5. TDV Series

    2  Pages

  6. ECU Series

    2  Pages

  7. 30RAP Series

    2  Pages

  8. 7 Series BTP

    4  Pages

  9. A3 SERIES

    2  Pages

  10. AVL series

    2  Pages

  11. GH-F

    2  Pages

  12. AF1000

    2  Pages

  13. BD series

    8  Pages

  14. Blending

    12  Pages

  15. Drying Brochure

    12  Pages

  16. PolyMag?

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.