Material Handling | Process Cooling | Temperature Control | Size Reduction Technical Specifications AEC's Hybrid Adiabatic Cooling System is a freeze proof solution that combines dry air cooling during the cooler months of the year with evaporative cooling during the warmer months, creating a true hybrid cooling system. It provides exceptional savings in water, energy, and maintenance while providing dependable, safe process cooling for nearly any application - in any environment. By eliminating standing water in the system, the potential for harmful bacteria growth is practically eliminated. With the closed-loop system, intelligent controls and robust fabrication - the AEC Hybrid Adiabatic Cooing System is an efficient, flexible, and sustainable approach to process cooling. WATER & ENERGY SAVINGS LOW MAINTENANCE IMPROVED HEALTH & SAFETY • Reduced water consumption, save • Freeze Proof • Reduced Risk of Legionnaries' Disease up to 95% annually versus traditional • Scale Resistant • Reduced Safety Issues tower systems. • Corrosion Resistant • No Blowdown • Reduced energy usage, save up to 86% versus packaged air cooled chillers. • Simplified Durable Design • Environmentally Friendly Mechanical Features • Stainless steel frame construction - 304SS • Misting nozzles — thermoplastic, (2) per section on each side • Aluminum fins — standard configuration is 14 fins per inch, phenolic epoxy coated. • Fans — 35" fan / 3 hp motor on 32.5" (STANDARD OUTPUT) — 38" fan / 5 hp motor on 70" (HIGH OUTPUT) • Glycol Additives: • EG (Ethylene glycol) organic compound additive. • PG (Propylene glycol) Used in food processing and considered safer for human and animal exposure Controls • Carel c.Pco PLC Control • Controls fan cycling & water spray • PID fan staging control • Setpoint is the temperature that activates the first fan. • Ethernet connectivity with pump tank system.

Open the catalog to page 1
AEC’s Hybrid Adiabatic Cooling System - 2

SpecificationsStandard Output 32.5" Face Height Hybrid Adiabatic Cooling System Number of 3 hp Fans * Capacity is based on the following conditions Fluid is 35% Ethylene Glycol, Ambient Air Conditions Dry Bulb = 95 °F, Wet Bulb = 77 °F, 82 °F Water spray on temperature, 95 °F Entering Fluid Temperature (EFT), 85 °F Leaving Fluid Temperature (LFT), 20 ft. head maximum head pressure, MCA & MOPD Ratings for 480V/3ph/60hz. ** Height is to the top of the mounted control panel SOLENOID VALVES LIFT POINTS Configuration AEC'S Hybrid Adiabatic Cooling System may contain two to seven BAR fans and...

Open the catalog to page 2

All AEC catalogs and technical brochures

  1. T50-Series

    2 Pages

  2. 30RB Series

    2 Pages

  3. AF Series

    2 Pages

  4. TDV Series

    2 Pages

  5. ECU Series

    2 Pages

  6. 30RAP Series

    2 Pages

  7. 7 Series BTP

    4 Pages

  8. A3 SERIES

    2 Pages

  9. AVL series

    2 Pages

  10. GH-F

    2 Pages

  11. AF1000

    2 Pages

  12. BD series

    8 Pages

  13. Blending

    12 Pages

  14. PolyMag?

    2 Pages