AEC's Hybrid Adiabatic Cooling System is designed to provide efficient and reliable cooling by combining dry air cooling in cooler months with evaporative cooling in warmer months. This hybrid system offers significant savings in water, energy, and maintenance while ensuring safe process cooling across various applications and environments. The system's closed-loop design minimizes the risk of harmful bacteria growth.

Mechanical Features
  • Constructed with a stainless steel frame (304SS).
  • Equipped with thermoplastic misting nozzles and aluminum fins coated with phenolic epoxy.
  • Available with two fan options: 35” fan with a 3 hp motor or 38” fan with a 5 hp motor.
  • Supports glycol additives like Ethylene Glycol (EG) and Propylene Glycol (PG).

Controls
  • Utilizes Carel c.Pco PLC Control for fan cycling and water spray management.
  • Features PID fan staging control and Ethernet connectivity with the pump tank system.

Benefits
  • Water & Energy Savings: Up to 95% water savings and 86% energy savings compared to traditional systems.
  • Health & Safety: Reduced risk of Legionnaires’ disease and other safety issues.
  • Low Maintenance: Freeze-proof, scale-resistant, and corrosion-resistant design.

Specifications
The system can be configured with two to seven fans, with varying heights to meet cooling requirements. The cooling capacity increases with the number of fans and the height of the unit.

Performance Data
  • Standard Output: Models range from HCS002 to HCS007, with cooling capacities from 144,000 to 530,000 BTU/hr.
  • High Output: Models range from HCS012 to HCS017, with cooling capacities from 277,000 to 962,000 BTU/hr.

Each model's performance is based on specific conditions, including fluid composition, ambient air conditions, and electrical ratings.
See more

Catalog excerpts

AEC’s Hybrid Adiabatic Cooling System-1

Material Handling | Process Cooling | Temperature Control | Size Reduction Technical Specifications AEC's Hybrid Adiabatic Cooling System is a freeze proof solution that combines dry air cooling during the cooler months of the year with evaporative cooling during the warmer months, creating a true hybrid cooling system. It provides exceptional savings in water, energy, and maintenance while providing dependable, safe process cooling for nearly any application - in any environment. By eliminating standing water in the system, the potential for harmful bacteria growth is practically eliminated. With the closed-loop system, intelligent controls and robust fabrication - the AEC Hybrid Adiabatic Cooing System is an efficient, flexible, and sustainable approach to process cooling. WATER & ENERGY SAVINGS LOW MAINTENANCE IMPROVED HEALTH & SAFETY • Reduced water consumption, save • Freeze Proof • Reduced Risk of Legionnaries' Disease up to 95% annually versus traditional • Scale Resistant • Reduced Safety Issues tower systems. • Corrosion Resistant • No Blowdown • Reduced energy usage, save up to 86% versus packaged air cooled chillers. • Simplified Durable Design • Environmentally Friendly Mechanical Features • Stainless steel frame construction - 304SS • Misting nozzles — thermoplastic, (2) per section on each side • Aluminum fins — standard configuration is 14 fins per inch, phenolic epoxy coated. • Fans — 35" fan / 3 hp motor on 32.5" (STANDARD OUTPUT) — 38" fan / 5 hp motor on 70" (HIGH OUTPUT) • Glycol Additives: • EG (Ethylene glycol) organic compound additive. • PG (Propylene glycol) Used in food processing and considered safer for human and animal exposure Controls • Carel c.Pco PLC Control • Controls fan cycling & water spray • PID fan staging control • Setpoint is the temperature that activates the first fan. • Ethernet connectivity with pump tank system.

 Open the catalog to page 1
AEC’s Hybrid Adiabatic Cooling System-2

SpecificationsStandard Output 32.5" Face Height Hybrid Adiabatic Cooling System Number of 3 hp Fans * Capacity is based on the following conditions Fluid is 35% Ethylene Glycol, Ambient Air Conditions Dry Bulb = 95 °F, Wet Bulb = 77 °F, 82 °F Water spray on temperature, 95 °F Entering Fluid Temperature (EFT), 85 °F Leaving Fluid Temperature (LFT), 20 ft. head maximum head pressure, MCA & MOPD Ratings for 480V/3ph/60hz. ** Height is to the top of the mounted control panel SOLENOID VALVES LIFT POINTS Configuration AEC'S Hybrid Adiabatic Cooling System may contain two to seven BAR fans and varies...

 Open the catalog to page 2

All AEC, Inc. - ACS Group catalogs and technical brochures

  1. T50-Series

    2  Pages

  2. AF1000 Series

    2  Pages

  3. 30RB Series

    2  Pages

  4. AF Series

    2  Pages

  5. TDV Series

    2  Pages

  6. ECU Series

    2  Pages

  7. 30RAP Series

    2  Pages

  8. 7 Series BTP

    4  Pages

  9. A3 SERIES

    2  Pages

  10. AVL series

    2  Pages

  11. GH-F

    2  Pages

  12. AF1000

    2  Pages

  13. BD series

    8  Pages

  14. Blending

    12  Pages

  15. Drying Brochure

    12  Pages

  16. PolyMag?

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.