1. Catalogs
  2. Adwa Hungary
  3. AD70000 Electrode Rinse Solution

AD70000 Electrode Rinse Solution

AD70000 Electrode Rinse Solution

AD70000 Electrode Rinse Solution

Product catalog summary
Product Identification: The document discusses the Electrode Rinse Solution, code AD70000, primarily composed of water (CAS number 7732-18-5).
Intended Use: This solution is designed for cleaning purposes.
Supplier Information: Supplied by Adwa Hungary Kft., located in Szeged, Hungary, with contact details provided for support.
Emergency Contacts: Includes emergency telephone numbers for various countries.
Hazards Identification: Not classified as hazardous under EC Regulation 1272/2008 (CLP), with no required hazard labeling and no PBT or vPvB substances above 0.1%.
Composition: Primarily water, with no significant quantities of hazardous substances.
First Aid Measures: No specific measures necessary; good industrial hygiene practices are recommended.
Firefighting Measures: Use carbon dioxide, foam, powder, or water spray. Firefighters should wear standard protective gear.
Accidental Release Measures: Use protective equipment, prevent water system entry, and dispose of according to regulations.
Handling and Storage: Prevent environmental leakage, store in labeled containers, and keep away from incompatible materials.
Exposure Controls/Personal Protection: No specific protective equipment required under normal conditions.
Physical and Chemical Properties: Colorless, odorless liquid with a pH of 7, relative density of 1.00, and water solubility.
Stability and Reactivity: Stable under normal conditions with no significant reactivity risks.
Toxicological Information: Does not meet criteria for acute toxicity, irritation, sensitization, mutagenicity, carcinogenicity, reproductive toxicity, or aspiration hazard.
Ecological Information: Use responsibly to avoid environmental contamination; no PBT or vPvB substances above 0.1%.
Disposal Considerations: Waste should be managed by authorized firms, and packaging disposed of according to regulations.
Transport Information: Not classified as dangerous for transport under ADR, RID, IMDG, or IATA regulations.
Regulatory Information: Not subject to specific restrictions or authorizations under various EU regulations.
Other Information: Includes a legend of abbreviations and references to EU regulations.
See more

Catalog excerpts

AD70000 Electrode Rinse Solution-1

Adwa Hungary Kft. AD70000 Electrode Rinse Solution Reviewed Only Dated 13/03/2017 Printed on 10/03/2017 Page n. 1/8 Information Sheet SECTION 1. Identification of the substance/mixture and of the company/undertaking. 1.1. Product identifier. Code. Product name. Chemical name and synonym. EC number. CAS number. Additional product Codes. 1.2. Relevant identified uses of the substance or mixture and uses advised against. Cleaning Solution. Intended use. 1.3. Details of the supplier of the safety data sheet. Name. Full address: e-mail address of the competent person. responsible for the Safety Data Sheet. 1.4. Emergency telephone number. For urgent inquiries refer to. SECTION 2. Hazards identification. 2.1. Classification of the substance or mixture. The product is not classified as hazardous pursuant to the provisions set forth in EC Regulation 1272/2008 (CLP) (and subsequent amendments and supplements). Hazard classification and indication: 2.2. Label elements. Hazard pictograms:

 Open the catalog to page 1
AD70000 Electrode Rinse Solution-2

Adwa Hungary Kft. AD70000 Electrode Rinse Solution Signal words: Reviewed Only Dated 13/03/2017 Printed on 10/03/2017 Page n. 2/8 Hazard statements: -- Precautionary statements: -- This product is not subject to hazard labeling pursuant to EC Regulation 1272/2008 (CLP) and subsequent amendments and supplements. 2.3. Other hazards. On the basis of available data, the product does not contain any PBT or vPvB in percentage greater than 0,1%. SECTION 3. Composition/information on ingredients. 3.1. Substances. The product does not contain substances classified as being hazardous to human health or...

 Open the catalog to page 2
AD70000 Electrode Rinse Solution-3

Adwa Hungary Kft. AD70000 Electrode Rinse Solution Reviewed Only Dated 13/03/2017 Printed on 10/03/2017 Page n. 3/8 GENERAL INFORMATION Use jets of water to cool the containers to prevent product decomposition and the development of substances potentially hazardous for health. Always wear full fire prevention gear. Collect extinguishing water to prevent it from draining into the sewer system. Dispose of contaminated water used for extinction and the remains of the fire according to applicable regulations. SPECIAL PROTECTIVE EQUIPMENT FOR FIRE-FIGHTERS Normal fire fighting clothing i.e. fire kit...

 Open the catalog to page 3
AD70000 Electrode Rinse Solution-4

Adwa Hungary Kft. AD70000 Electrode Rinse Solution Reviewed Only Dated 13/03/2017 Printed on 10/03/2017 Page n. 4/8 8.2. Exposure controls. Comply with the safety measures usually applied when handling chemical substances. HAND PROTECTION None required. SKIN PROTECTION None required. EYE PROTECTION None required. RESPIRATORY PROTECTION None required, unless indicated otherwise in the chemical risk assessment. ENVIRONMENTAL EXPOSURE CONTROLS. The emissions generated by manufacturing processes, including those generated by ventilation equipment, should be checked to ensure compliance with environmental...

 Open the catalog to page 4
AD70000 Electrode Rinse Solution-5

Adwa Hungary Kft. AD70000 Electrode Rinse Solution Reviewed Only Dated 13/03/2017 Printed on 10/03/2017 Page n. 5/8 There are no particular risks of reaction with other substances in normal conditions of use. 10.2. Chemical stability. The product is stable in normal conditions of use and storage. 10.3. Possibility of hazardous reactions. No hazardous reactions are foreseeable in normal conditions of use and storage. 10.4. Conditions to avoid. None in particular. However the usual precautions used for chemical products should be respected. 10.5. Incompatible materials. Information not available....

 Open the catalog to page 5
AD70000 Electrode Rinse Solution-6

Adwa Hungary Kft. AD70000 Electrode Rinse Solution Reviewed Only Dated 13/03/2017 Printed on 10/03/2017 Page n. 6/8 12.1. Toxicity. Information not available. 12.2. Persistence and degradability. Information not available. 12.3. Bioaccumulative potential. Information not available. 12.4. Mobility in soil. Information not available. 12.5. Results of PBT and vPvB assessment. On the basis of available data, the product does not contain any PBT or vPvB in percentage greater than 0,1%. 12.6. Other adverse effects. Information not available. SECTION 13. Disposal considerations. 13.1. Waste treatment...

 Open the catalog to page 6
AD70000 Electrode Rinse Solution-7

Adwa Hungary Kft. AD70000 Electrode Rinse Solution 14.5. Environmental hazards. Not applicable. 14.6. Special precautions for user. Not applicable. 14.7. Transport in bulk according to Annex II of Marpol and the IBC Code. Information not relevant. SECTION 15. Regulatory information. 15.1. Safety, health and environmental regulations/legislation specific for the substance or mixture. Seveso Category - Directive 2012/18/EC: Restrictions relating to the product or contained substances pursuant to Annex XVII to EC Regulation 1907/2006. None. Substances in Candidate List (Art. 59 REACH). On the basis...

 Open the catalog to page 7
AD70000 Electrode Rinse Solution-8

Adwa Hungary Kft. AD70000 Electrode Rinse Solution Reviewed Only Dated 13/03/2017 Printed on 10/03/2017 Page n. 8/8 15.2. Chemical safety assessment. No chemical safety assessment has been processed for the mixture and the substances it contains. SECTION 16. Other information. LEGEND: - ADR: European Agreement concerning the carriage of Dangerous goods by Road - CAS NUMBER: Chemical Abstract Service Number - CE50: Effective concentration (required to induce a 50% effect) - CE NUMBER: Identifier in ESIS (European archive of existing substances) - CLP: EC Regulation 1272/2008 - DNEL: Derived No...

 Open the catalog to page 8

All Adwa Hungary catalogs and technical brochures

  1. PRODUCT CATALOG

    20  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.