brochure expression CMS
5Pages

{{requestButtons}}

Catalog excerpts

brochure expression CMS - 1

Over 25 Years of Mass Spec Experience Mass Spectrometers Designed for Chemists Compact. Fast. Easy. Versatile. Advion.com

Open the catalog to page 1
brochure expression CMS - 2

Compact Mass Spectrometry Unrivalled Utility and Flexibility With over 25 years of mass spectrometry and chemistry expertise, Advion has produced a family of compact mass spectrometers (CMS) designed for the chemist. The affordability, small size and ease-of-use makes them ideal for use directly at the chemist’s bench, giving immediate answers and informed decisions instead of waiting in line at a central analytical service laboratory. Now every chemist can have a mass spec that works the same hours they do. With electrospray (ESI) and atmospheric pressure chemical ionization (APCI) ion...

Open the catalog to page 2
brochure expression CMS - 3

The Industry’s Broadest Range of Innovative Sampling Techniques Advion provides an extensive range of innovative sample introduction systems that are fully integrated with the expression CMS to provide solutions for all the chemist's needs. From the simplest, fastest direct probe analysis requiring no sample preparation to ultra-high performance compound separation with state-of-the-art liquid chromatography systems. Plate Express™ TLC Plate Reader Plate Express provides a simple, automated means of obtaining mass spectra directly from TLC plates, combined with Advion’s expression compact...

Open the catalog to page 3
brochure expression CMS - 4

Full-Feature & Easy-to-Use Software for Simplified Operation and Compound Identification Maximize Your Results and Return on Investment Simultaneous integration with several techniques Placed at the center of the chemist’s workflow, the expression CMS can provide critical information for many processes; reaction monitoring, separation, purification, and impurity determination. Advion’s Full Suite of software products for the expression CMS It can be integrated with several techniques at once and the chemist can move effortlessly between these techniques in seconds without the need to...

Open the catalog to page 4
brochure expression CMS - 5

Specification Ion Source ESI, APCI or APCI/ASAP Polarity Positive & negative ion switching in a single analysis Flow Rate Range ESI: 10 pL/min to 1 mL/min APCI: 10 pL/min to 2 mL/min m/z Range expression5m/z 10 to 1,200 injection at 100 pL/min) 100:1 S/N (RMS) with SIM of m/z 609.3. Accuracy +/- 0.1 m/z units of the entire acquisition range Stability 0.1 m/z units at m/z 1,200 over 12 hour period at operating temperature of 20°C +/- 1°C Polarity Switching 50 ms Speed Dynamic Range 4.5 orders of magnitude System/Space Requirements Gas Supply 60 psi, >98% pure Nitrogen...

Open the catalog to page 5