INDUCTIVE FILTER CARDS
9Pages

{{requestButtons}}

Catalog excerpts

INDUCTIVE FILTER CARDS - 1

INDUCTIVE FILTER CARDS Filter Cards Model Number Inductance Line to Line Continuous Current Voltage Rating FC1010 20ìH 10A 200V FC10010 200ìH 10A 250V Filter Cards for Single Phase Loads: Brushed Motors, Voice Coils, and other Single Phase Loads FC15030 300ìH 30A 400V BFC1010 20ìH 10A 200V BFC10010 200ìH 10A 250V BFC15030 300ìH 30A 400V Filter Cards for Three Phase Loads: Brushless Motors, Linear Motors, and other Three Phase Loads BFC15030800 300ìH 30A 800V FC1010 FC10010 FC15030 BFC1010 BFC10010 BFC15030 BFC15030800 Description Features .. Increases Load Inductance .. Small Size, Low Cost, Ease of Use .. Provides Dramatic Noise Reduction Agency Approvals US and Canadian safety compliance with UL 508c, the industrial standard for power conversion electronics. UL registered under file number E140173. Note that machine components compliant with UL are considered UL registered as opposed to UL listed, as would be the case for commercial products. Compliant with European CE for both the Class A EMC Directive 2004/108/EC on Electromagnetic Compatibility (specifically EN 61000-6-4:2001, EN 61000-6-2:2001, EN 61000-3-2:2000, and EN 61000-3-3:1995/A1:2001) and LVD requirements of directive 2006/95/EC (specifically EN 60204-1), a low voltage directive to protect users from electrical shock. The FC and BFC series of filter cards have been designed to complement ADVANCED Motion Controls’ servo drives. These filters contain two inductors for single phase loads and three inductors for three phase loads. Inductive filter cards have two typical applications: 1. To increase the inductance to meet the minimum load inductance requirement of ADVANCED Motion Controls servo drives. Some motors have inductances that are less than the minimum load inductance requirement for the servo drive. For example, “basket-wound” and “pancake” motors do not have a conventional iron core rotor so the winding inductance is usually less than 25 ìH. For this type of application the filter card should be sized so the total inductance of the motor plus filter card meets or exceeds the inductance requirements of the servo drive. The filter card must also be rated to the required current. 2. To reduce the DV/DT of the motor outputs. The main source of emitted drive noise is the high DV/DT (typically about 1V/nanosecond) of the drive’s output power stage. Unfiltered motor outputs can introduce noise in digital encoder signals. For applications with noise sensitive devices (e.g. video cameras, magnetic/capacitive sensors) the use of an external inductive filter card may reduce emitted noise. Note: Most applications do not require external filters. RoHS (Reduction of Hazardous Substances) is intended to prevent hazardous substances such as lead from being manufactured in electrical and electronic equipment. Release Date: 9/14/2010 Revision: 2.01 ADVANCED Motion Controls · 3805 Calle Tecate, Camarillo, CA, 93012 ph# 805-389-1935 · fx# 805-389-1165· www.a-m-c.com Page 1 of 9

Open the catalog to page 1
INDUCTIVE FILTER CARDS - 2

INDUCTIVE FILTER CARDS SPECIFICATIONS Power Specifications Description Units FC1010 FC10010 FC15030 BFC1010 BFC10010 BFC15030 BFC15030800 Inductance (Line to Line) ìH 20 200 300 20 200 300 300 Continuous Current A 10 10 30 10 10 30 30 Voltage Rating VDC 200 250 400 200 250 400 800 Capacitance (C) ìF - .01 .068 - .01 - - Mechanical Specifications Description Units FC1010 FC10010 FC15030 BFC1010 BFC10010 BFC15030 BFC15030800 Connector - Screw Terminals Size (HxWxD) mm (in) 56.5x28.0x15.8 (2.23x1.10x0.62) 65.3x51.3x25.7 (2.57x2.02x1.01) 101.6x88.9x44.5 (4.00x3.5x1.75) 56.5x28.6x15.8...

Open the catalog to page 2
INDUCTIVE FILTER CARDS - 3

INDUCTIVE FILTER CARDS MOUNTING DIMENSIONS Release Date: 9/14/2010 Revision: 2.01 ADVANCED Motion Controls · 3805 Calle Tecate, Camarillo, CA, 93012 ph# 805-389-1935 · fx# 805-389-1165· www.a-m-c.com Page 3 of 9

Open the catalog to page 3
INDUCTIVE FILTER CARDS - 4

INDUCTIVE FILTER CARDS Release Date: 9/14/2010 Revision: 2.01 ADVANCED Motion Controls · 3805 Calle Tecate, Camarillo, CA, 93012 ph# 805-389-1935 · fx# 805-389-1165· www.a-m-c.com Page 4 of 9

Open the catalog to page 4
INDUCTIVE FILTER CARDS - 5

INDUCTIVE FILTER CARDS Release Date: 9/14/2010 Revision: 2.01 ADVANCED Motion Controls · 3805 Calle Tecate, Camarillo, CA, 93012 ph# 805-389-1935 · fx# 805-389-1165· www.a-m-c.com Page 5 of 9

Open the catalog to page 5
INDUCTIVE FILTER CARDS - 6

INDUCTIVE FILTER CARDS Release Date: 9/14/2010 Revision: 2.01 ADVANCED Motion Controls · 3805 Calle Tecate, Camarillo, CA, 93012 ph# 805-389-1935 · fx# 805-389-1165· www.a-m-c.com Page 6 of 9

Open the catalog to page 6
INDUCTIVE FILTER CARDS - 7

INDUCTIVE FILTER CARDS Release Date: 9/14/2010 Revision: 2.01 ADVANCED Motion Controls · 3805 Calle Tecate, Camarillo, CA, 93012 ph# 805-389-1935 · fx# 805-389-1165· www.a-m-c.com Page 7 of 9

Open the catalog to page 7
INDUCTIVE FILTER CARDS - 8

INDUCTIVE FILTER CARDS Release Date: 9/14/2010 Revision: 2.01 ADVANCED Motion Controls · 3805 Calle Tecate, Camarillo, CA, 93012 ph# 805-389-1935 · fx# 805-389-1165· www.a-m-c.com Page 8 of 9

Open the catalog to page 8
INDUCTIVE FILTER CARDS - 9

INDUCTIVE FILTER CARDS CUSTOMIZATION INFORMATION ADVANCED Motion Controls’ products are available in many configurations. All models listed in the selection tables of the website are readily available, standard product offerings. ADVANCED Motion Controls also has the capability to promptly develop and deliver specified products for OEMs with volume requests. Our Applications and Engineering Departments will work closely with your design team through all stages of development in order to provide the best servo drive solution for your system. Equipped with on-site manufacturing for quick-turn...

Open the catalog to page 9

All Advanced Motion Controls catalogs and technical brochures

  1. dc201e60a40nac

    12 Pages

  2. mc1xdzc02-qd

    9 Pages

  3. ps50a

    4 Pages

  4. se10a40

    8 Pages

  5. srst400

    4 Pages

  6. sx30a8

    8 Pages

  7. zbdc6a6

    5 Pages

  8. zbh6a6

    9 Pages

  9. z6a6

    5 Pages

  10. z12a8

    5 Pages

  11. 25a17

    2 Pages

  12. 20a20

    9 Pages

  13. PS16 SERIES

    5 Pages

  14. PS300 SERIES

    4 Pages

Archived catalogs