Catalog excerpts

INNOVA 1409 A reliable, fully remote-controlled multipoint gas sampler for up to 24 different locations The Innova® 1409 multipoint sampler is designed to extend the capabilities of Innova gas monitors. The 1409 is delivered as a 6, 12, or 24 channel multipoint sampler, enabling gas samples to be drawn from up to 24 different sampling locations and delivered to the gas monitor. PRODUCT HIGHLIGHTS ■ Full remote control over the USB interface: the system controller can either be the gas monitor or an online PC ■ 6 to 24 sample input channels depending on the configuration ■ Self-test function ■ Pneumatic system constructed of AISI-316 Stainless Steel and PTFE tubing to minimize gas adsorption ■ Integrates seamlessly with the Innova Photoacoustic Gas Monitors ■ LED indicators for active channel and interface TYPICAL APPLICATIONS ■ Occupational safety and health area monitoring - air sampling in up to 24 locations and delivery of the sample to an Innova photoacoustic monitor ■ Leak monitoring - air sampling with good spatial distribution (up to 24 sampling points) across large enclosed rooms, and delivering the sample to a central monitor unit ■ Multipoint gas analysis - parallel processing of multiple gas cells or chambers with a unique monitor ©2019 Advanced Energy Industries, Inc.
Open the catalog to page 1
The sampling system is configured from the system controller: either directly via the front panel interface of the gas monitor, or using one of the available software (BZ7007 or LumaSoft 7880). The 1409 communicates with the gas monitor over a USB interface. When using LumaSoft 7880 as a system controller, the computer is connected to the gas monitor via the RS232 serial, USB, or Ethernet interface. The pneumatic system of the 1409 is shown below. The sampler system is constructed of AISI-316 stainless steel and PTFE (poly-tetrafluoroethylene) tubing to minimize adsorption of samples. The...
Open the catalog to page 2
TECHNICAL DATA Sampler Specifications Included Accessories ■ Knurled nuts to secure tubing to nozzles (3xYM0652) ■ USB interface cable (AS0001) ■ Remote/offline software (BZ7007) ■ Mains cable ■ Instruction manual Warning The Innova 1409 must not be placed in areas with flammable gases/vapors in explosive concentrations or be used to monitor explosive concentrations of these. Certain aggressive gases can damage the internal airways of the 1409. Contact your Advanced Energy sales representative for further information. Pump Performance Two external pumps are available:
Open the catalog to page 3
MEASURING DETAILS Control of the 1409 The 1409 is remotely controlled either by using the gas monitor as a system controller (the monitoring/ sampling system then operates in standalone mode), or by LumaSoft 7880 Multipoint Software running on a computer connected to the gas monitor and communicating over the RS232, USB, or Ethernet interface. Commands and information requests are sent over the USB interface to the 1409 to control the sampler system and to read-out data. System Use The 1409 combined with a gas monitor offers wide-ranging monitoring capabilities. The 1409 makes it possible...
Open the catalog to page 4
MONITORING SETUPS Online Multipoint Monitoring The Innova 1409 Multipoint Sampler is connected to one Innova Photoacoustic Gas Monitor via USB interface. The system (Sampler + Monitor) is controlled remotely by the LumaSoft Gas Multipoint 7880 software from a PC which can connect to the gas monitor via RS232, USB, or Ethernet. The software provides online monitoring features, including a real-time display of the data. Standalone Multipoint Monitoring The Innova 1409 Multipoint Sampler is connected to one Innova Photoacoustic Gas Monitor via USB interface. The gas monitor is the system...
Open the catalog to page 5
Data Output Seongi Data I Tan* Rang* FotMeaftsan** 07 35 18 Tuwday 0«ob*r 13.2015 (3* L«tMNw»«M 093300 feday Nov*rbar 06.2015 □ * RabMh Oat* l Tana Rang* LumaSoft 7880 With LumaSoft 7880, the systems operates in online mode with numeric and graphic windows showing the measurement values and other appropriate information for each sample channel and each gas in real time. BZ7007 When the gas monitor and the 1409 Multipoint Sampler run as a standalone system, the Remote/ offline software (BZ7007) can be used to retrieve the measurement log from the monitor’s memory and then export it in MS...
Open the catalog to page 6
Advanced Energy For international contact information visit advancedenergy.com. sales.support@aei.com +1 970 221 0108 ABOUTADVANCED ENERGY Advanced Energy (AE) has devoted more than three decades to perfecting power for its global customers. AE designs and manufactures highly engineered, precision power conversion, measurement and control solutions for mission-critical applications and processes. AE’s power solutions enable customer innovation in complex semiconductor and industrial thin film plasma manufacturing processes, demanding high and low voltage applications, and...
Open the catalog to page 8All ADVANCED ENERGY catalogs and technical brochures
-
CSM Power solutions Catalog
12 Pages
-
Horticultural Lighting sheet
1 Pages
-
LCM brochure
4 Pages
-
eVos me Datasheet
2 Pages
-
eVos datasheet
2 Pages
-
eVerest datasheet
12 Pages
-
Navigator Networks datasheet
8 Pages
-
Paramount Plus datasheet
8 Pages
-
Ascent AMS datasheet
6 Pages
-
Ascent AP datasheet
8 Pages
-
Ascent DMS datasheet
8 Pages
-
Medical Power Supplies Brochure
20 Pages
-
SCR Thyro-PX DC datasheet
8 Pages
-
Impac IGAR 6 Datasheet
8 Pages
-
Luxtron M-1000 Datasheet
4 Pages
-
Luxtron M-1100 Datasheet
4 Pages
-
Glass Solutions Brochures
20 Pages
-
Petrochemical Solutions Brochure
16 Pages
-
Datasheet Impac Series 600
10 Pages
-
Impac Pyrometer Overview
28 Pages
-
Basic Bus Module
2 Pages
-
Thyro S Series Datasheet
10 Pages
-
Thyro PX Series Datasheet
11 Pages
-
Thyro A Series Datasheet
10 Pages
-
Thyro A+ Series Datasheet
8 Pages
-
FBG Analyzer Series
4 Pages
-
ON-SITE INFRARED SURVEY
4 Pages
-
xgen series
56 Pages
-
THYRO-FAMILY ACCESSORIES
12 Pages
-
HIGH VOLTAGE POWER SUPPLIES
8 Pages
-
Apex 3k5PIN Conversion
4 Pages
-
UV 400 Pyrometer Datasheet
8 Pages
-
Luxtron FOT probes
2 Pages
-
Luxtron M924 FOT OEM-Module
4 Pages
-
E2T Pulsar4 Datasheet
8 Pages
-
E2T Quasar 2 Datasheet
4 Pages
-
FlareSpection Datasheet
4 Pages
-
ThermalSpection 724DV Datasheet
12 Pages
-
BoilerSpection Datasheet
4 Pages
-
Innova 3731 Datasheet
8 Pages
-
Gas Sensing Overview
16 Pages
-
XSOLO
8 Pages
-
XF
8 Pages
-
COOLX®600
8 Pages
-
COOLX®1800
12 Pages
-
COOLX®1000
11 Pages
-
POWER FOR GLASS COATING
4 Pages
-
ASCENT AMS DC POWER SUPPLIES
6 Pages
-
IMPAC IS 50-LO/GL
4 Pages
-
IMPAC IPE 140
8 Pages
-
IMPAC IPE 140/39
2 Pages
-
IMPAC IN 140/5 SERIES
8 Pages
-
IMPAC SERIES 8 PRO
8 Pages