Catalog excerpts

ULTRAVOLT HIGH POWER 1/8C TO 6C SERIESSINGLE OUTPUT 60, 125, OR 250 W CAPACITOR CHARGING SUPPLY The UltraVolt® High Power C Series of regulated DC-to-DC converters are designed for high voltage capacitor charging applications that demand fast rise times with controlled voltage overshoot PRODUCT HIGHLIGHTS ■ Regulated high voltage outputs ranging from 125 to 6000 VDC maximum ■ Single output: positive or negative polarity models ■ Choice of 60, 125, or 250 W maximum power ■ 24 VDC input ■ Output ripple performance < 1.0 % ■ Controlled high voltage overshoot enhances longevity of external load components ■ Temperature coefficient 50 ppm/°C ■ Simplified integration with available 0 to 5 VDC or 0 to 10 VDC interface ■ Reliable modular design ■ Factory-configured performance, control and integration options ■ UL/cUL recognized, IEC-60950-1, CE Mark (LVD and RoHS) Maximum Output Voltage 125, 250, 500, 1 kV, 2 kV, 4 kV, or 6 kV DC Maximum Output Power 60, 125,or 250W Type Single Output TYPICAL APPLICATIONS ■ Capacitive charging and pulsed power applications ■ High potential testing and Electrostatic Discharge (ESD) ■ Automated Test Equipment (ATE) ■ Lasers and opto-electronics ■ Ultrasonic pulse generators Ripple < 1.0 % Control Analog Temperature Coefficient 50 ppm/°C Ordering Information on Page 7 ©2023 Advanced Energy Industries, Inc.
Open the catalog to page 1
1Standard product specifications shown unless noted. Custom configurations are available. 2Nominal ripple measured @ 100% HVout, 100% LOAD . Valid for 10 to 100% HVout range.
Open the catalog to page 2
ULTRAVOLT HIGH POWER 1/8C TO 6C SERIES ELECTRICAL SPECIFICATIONS (CONTINUED) Environmental Operating Temperature Range -40 to 65°C (-40 to 149°F) bottom case temperature Regulatory Certifications UL/cUL recognized, IEC-60950-1, CE mark (LVD and RoHS) MECHANICAL SPECIFICATIONS PART NUMBER PROPRIETARY STATEMENT: ULTRAVOLT INC. CONFIDENTIAL DRAWING PART NUMBER PROPRIETARY STATEMENT: ULTRAVOLT INC. CONFIDENTIAL DRAWING Construction Standard Case A Aluminum (Anodized per MIL-A-8625 Type II) Aluminum (Anodized, -H Option) Zinc-plated steel (-Z11 Option) Static-dissipative polyester Natural...
Open the catalog to page 4
INTERFACE Connections — 60 W and 125 W Units
Open the catalog to page 5
INTERFACE (CONTINUED) Connections — 250 W Units (Continued) RISE TIME / CAPACITOR CHARGING (Co+Cx)x HVout Trise = lout lout = (Co + Cx)xHVout x freq Pout = (Co+Cx) x (HVout)2 2x Trise Trise = Rise time (Seconds) Co = Internal storage capacitance (Farads) Cx = External capacitive load (Farads) freq = Switching frequency (Hz) HVout = Output voltage (VDC) lout = Output current (Amps) Pout = Output power (Watts) STANDARD OPTIONS The High Power C series can be configured with options that adapt its performance and packaging to many application requirements. Customized models to meet specialized...
Open the catalog to page 6
ORDERING INFORMATION * Available only with I5 or I 10 options * -DA and -DAR not available with a -Z11 option Standard Part Output Voltage Output Power Model Output Polarity Input Voltage
Open the catalog to page 7
ABOUT ADVANCED ENERGY Since 1981, Advanced Energy (AE) — and its UltraVolt® family of products — has perfected how power performs for its customers. For both end users and OEMs, AE’s comprehensive portfolio of standard and custom high-voltage components precisely match system specifications to deliver unparalleled energy, quality, and performance. Through close customer collaboration, design expertise, application insight, and world-class support, AE creates successful partnerships and enables customers to push the boundaries of innovation and stay ahead of evolving market needs. PRECISION...
Open the catalog to page 8All ADVANCED ENERGY catalogs and technical brochures
-
CSM Power solutions Catalog
12 Pages
-
Horticultural Lighting sheet
1 Pages
-
LCM brochure
4 Pages
-
eVos me Datasheet
2 Pages
-
eVos datasheet
2 Pages
-
eVerest datasheet
12 Pages
-
Navigator Networks datasheet
8 Pages
-
Paramount Plus datasheet
8 Pages
-
Ascent AMS datasheet
6 Pages
-
Ascent AP datasheet
8 Pages
-
Ascent DMS datasheet
8 Pages
-
Medical Power Supplies Brochure
20 Pages
-
SCR Thyro-PX DC datasheet
8 Pages
-
Impac IGAR 6 Datasheet
8 Pages
-
Luxtron M-1000 Datasheet
4 Pages
-
Luxtron M-1100 Datasheet
4 Pages
-
Glass Solutions Brochures
20 Pages
-
Petrochemical Solutions Brochure
16 Pages
-
Datasheet Impac Series 600
10 Pages
-
Impac Pyrometer Overview
28 Pages
-
Basic Bus Module
2 Pages
-
Thyro S Series Datasheet
10 Pages
-
Thyro PX Series Datasheet
11 Pages
-
Thyro A Series Datasheet
10 Pages
-
Thyro A+ Series Datasheet
8 Pages
-
FBG Analyzer Series
4 Pages
-
ON-SITE INFRARED SURVEY
4 Pages
-
xgen series
56 Pages
-
THYRO-FAMILY ACCESSORIES
12 Pages
-
HIGH VOLTAGE POWER SUPPLIES
8 Pages
-
Apex 3k5PIN Conversion
4 Pages
-
UV 400 Pyrometer Datasheet
8 Pages
-
Luxtron FOT probes
2 Pages
-
Luxtron M924 FOT OEM-Module
4 Pages
-
E2T Pulsar4 Datasheet
8 Pages
-
E2T Quasar 2 Datasheet
4 Pages
-
FlareSpection Datasheet
4 Pages
-
ThermalSpection 724DV Datasheet
12 Pages
-
BoilerSpection Datasheet
4 Pages
-
Innova 3731 Datasheet
8 Pages
-
Gas Sensing Overview
16 Pages
-
XSOLO
8 Pages
-
XF
8 Pages
-
COOLX®600
8 Pages
-
COOLX®1800
12 Pages
-
COOLX®1000
11 Pages
-
POWER FOR GLASS COATING
4 Pages
-
ASCENT AMS DC POWER SUPPLIES
6 Pages
-
IMPAC IS 50-LO/GL
4 Pages
-
IMPAC IPE 140
8 Pages
-
IMPAC IPE 140/39
2 Pages
-
IMPAC IN 140/5 SERIES
8 Pages
-
IMPAC SERIES 8 PRO
8 Pages