video corpo

Innova 1314i Gas Monitor Datasheet
8Pages

{{requestButtons}}

Catalog excerpts

Innova 1314i Gas Monitor Datasheet - 1

INNOVA 1314i Highly accurate, reliable, stable, and remote controllable quantitative gas monitoring system The Innova® 1314i Photoacoustic Gas Monitor is a highly accurate, reliable, and stable quantitative gas monitoring system. Its measurement system, based on the photoacoustic infrared detection method, is capable of measuring almost any gas that absorbs infrared light. AT A GLANCE Measurement Technique Photoacoustic Infrared Spectroscopy PRODUCT HIGHLIGHTS Filter Capacity ■ Selectively measures a wide range of gases/vapors ■ Linear response over a wide dynamic range ■ Stable and reliable: ensuring a maximum of only two calibrations a year ■ User-friendly: easy calibration, configuration, and viewing/analyzing of data via PC ■ Accurate: compensates for temperature and pressure fluctuations, water vapor interference, and interference from other known gases ■ Operates immediately: virtually no warm-up time necessary ■ Remote control capability via TCP/IP network interface protocol ■ Expandable up to 24 locations with the Innova 1409 Multipoint Sampler: the gas monitor can operate as the system controller for full standalone operation Up to 5 + water from 27 different filter options Detection Limit Gas dependent, but typically in the ppb region Repeatability 1% of measured value TYPICAL APPLICATIONS ■ Emission monitoring - of exhausts from chemical processes, NH3 in stacks, scrubber efficiency, and filter break-through ■ Process quality control measurements - of trace impurities in pure gas production ■ Occupational health and safety measurements - of possible production or accumulation of toxic/carcinogenic substances in working areas ■ Automotive monitoring - of alcohol content in vehicle exhausts and production of NH3 and N2O in diesel exhausts ©2019 Advanced Energy Industries, Inc.

Open the catalog to page 1
Innova 1314i Gas Monitor Datasheet - 2

Gas selectivity for the Innova 1314i monitor is achieved through the use of optical filters. By installing up to five filters, the 1314i can measure the concentration of up to five component gases and water vapor in any air sample. The detection limit is gas-dependent, but is typically in the ppb region. Reliability is ensured by a series of self tests performed by the monitor. The self tests check software, data integrity, and the 1314i’s components to ensure that they function properly. If a fault is found, it is reported in the measurement results, so that the integrity of the results...

Open the catalog to page 2
Innova 1314i Gas Monitor Datasheet - 3

MEASURING DETAILS Selectivity The gas selectivity of the 1314i is determined by the optical filters installed in its filter wheel. Because water is nearly always present in ambient air and absorbs infrared light at most wavelengths, it contributes to the total acoustic signal in the analysis cell. Therefore, the monitor is permanently fitted with a special filter that measures water vapor and enables the 1314i to compensate for water vapor interference. By selecting different filters, this technique can also be used to cross-compensate for known interferent gases. Calibration After the...

Open the catalog to page 3
Innova 1314i Gas Monitor Datasheet - 4

1Detection limit is @ 5 s S.I.T. 2Measured @ 20°C, 1013 mbar, and relative humidity (RH): 60%. (A concentration of 100x detection limit4 was used in determining these specifications.) 3Measured @ 1013 mbar and RH: 60%. 4Measured @ 20°C and RH: 60%.

Open the catalog to page 4
Innova 1314i Gas Monitor Datasheet - 5

Pumping System Specifications Warning The Innova 1314i must not be placed in areas with flammable gases/vapors in explosive concentrations or be used to monitor explosive concentrations of these. Monitoring of certain aggressive gases or a very high concentration of water vapor may damage the 1314i. Contact your Advanced Energy sales representative for further information.

Open the catalog to page 5
Innova 1314i Gas Monitor Datasheet - 6

MEASUREMENT DATA Online Measurement Results Using one or more of the monitor’s standard interfaces, measurement results are transferred directly to a PC. Here the results can be displayed on screen as real-time values in tables and graphs (see Fig. 1) or integrated into the process system. In the 7820/7880 software, the graphs can be configured to display only the desired gases, defined concentration ranges, and results from statistical analyses. Also, when using the 7880 software, all measurement data is stored in user-defined SQL Server 2014 database. Fig. 1: The graphical window shows up...

Open the catalog to page 6
Innova 1314i Gas Monitor Datasheet - 7

ORDERING INFORMATION Optical filters necessary for the user’s monitoring task can be ordered together with the 1314i and installed by Advanced Energy. The 1314i is then delivered zero-point and humidity interference calibrated. Included Accessories ■ 4 m PTFE tubing (AT 2177) ■ Particle filter (DS 0759B) ■ Fuse(VF0102A) ■ Set-up tree (BR6011) ■ Mains cable ■ USB cable (AS0001A) ■ Calibration software (BZ7002) ■ Offline software (BZ7003) ■ LumaSoft single point monitoring software (7820) ■ Instruction manual Additional Option The 1314i can be span-calibrated for certain gases -contact your...

Open the catalog to page 7
Innova 1314i Gas Monitor Datasheet - 8

Advanced Energy For international contact information visit advancedenergy.com. sales.support@aei.com +1 970 221 0108 ABOUTADVANCED ENERGY Advanced Energy (AE) has devoted more than three decades to perfecting power for its global customers. AE designs and manufactures highly engineered, precision power conversion, measurement and control solutions for mission-critical applications and processes. AE’s power solutions enable customer innovation in complex semiconductor and industrial thin film plasma manufacturing processes, demanding high and low voltage applications, and...

Open the catalog to page 8

All ADVANCED ENERGY catalogs and technical brochures

  1. LCM brochure

    4 Pages

  2. xgen series

    56 Pages

  3. XSOLO

    8 Pages

  4. XF

    8 Pages

  5. COOLX®600

    8 Pages

  6. COOLX®1800

    12 Pages

  7. COOLX®1000

    11 Pages