video corpo

Cylindrical Mounts - Rubber
1 /19Pages

Cylindrical Mounts - Rubber

Cylindrical Mounts - Rubber
1 /19Pages

Catalog excerpts

Cylindrical Mounts - Rubber-1

Cylindrical Mounts - To 13.3 lbs.www.vibrationmounts.com Phone: 516.328.3662 Fax: 516.328.3365 MATERIAL: Fasteners - Steel, Zinc Plated Isolator - Natural Rubber • FOR COMPRESSION LOADS OF 4.9 TO 13.3 POUNDS (2.2 TO 6 kgf) • FOR SHEAR LOADS OF 2.7 TO 6.4 POUNDS (1.2 TO 2.9 kgf) NOTE: Maximum unthreaded portion of stud does not exceed 1/16 inch (1.59 mm). LOAD DEFLECTION GRAPHS Deflections below the line x-x are considered safe practice for static loads; data above that line are useful for calculating deflections under dynamic loads. DEFLECTION (in.) Catalog Number *At these forcing frequencies, lesser loads will yield less than 81% isolation.

 Open the catalog to page 1
Cylindrical Mounts - Rubber-2

Cylindrical Mounts - To 25 lbs. www.vibrationmounts.com Phone: 516.328.3662 Fax: 516.328.3365 MATERIAL: Fasteners - Hardened Steel, Zinc Plated Isolater - Natural Rubber • FOR COMPRESSION LOADS OF 8 TO 25 POUNDS (3.6 TO 11.3 kgf) • FOR SHEAR LOADS OF 4.4 TO 12.5 POUNDS (2 TO 5.7 kgf) NOTE: Dimensions in ( ) are mm. NOTE: Maximum unthreaded portion of stud does not exceed 1/16 inch (1.59 mm). LOAD DEFLECTION GRAPHS Deflections below the line x-x are considered safe practice for static loads; data above that line are useful for calculating deflections under dynamic loads. DEFLECTION (in.) DEFLECTION...

 Open the catalog to page 2
Cylindrical Mounts - Rubber-3

Cylindrical Mounts - To 28.5 lbs.www.vibrationmounts.com Phone: 516.328.3662 Fax: 516.328.3365 MATERIAL: Fasteners - Steel, Zinc Plated Isolator - Natural Rubber FOR COMPRESSION LOADS OF 22 TO 28.5 POUNDS (10 TO 12.9 kgf) • FOR SHEAR LOADS OF 8.4 TO 11.9 POUNDS (3.8 TO 5.4 kgf) NOTE: Dimensions in ( ) are mm. NOTE: Maximum unthreaded portion of stud does not exceed 1/16 inch (1.59 mm). LOAD DEFLECTION GRAPHS Deflections below the line x-x are considered safe practice for static loads; data above that line are useful for calculating deflections under dynamic loads. DEFLECTION (in.) Catalog Number...

 Open the catalog to page 3
Cylindrical Mounts - Rubber-4

Cylindrical Mounts - To 75 lbs.www.vibrationmounts.com Phone: 516.328.3662 Fax: 516.328.3365 MATERIAL: Fasteners - Steel, Zinc Plated Isolator - Natural Rubber • FOR COMPRESSION LOADS OF 40 TO 75 POUNDS (18.1 TO 34 kgf) • FOR SHEAR LOADS OF 19 TO 42 POUNDS (8.6 TO 19.1 kgf) NOTE: Maximum unthreaded portion of stud does not exceed 1/16 inch (1.59 mm). LOAD DEFLECTION GRAPHS Deflections below the line x-x are considered safe practice for static loads; data above that line are useful for calculating deflections under dynamic loads. DEFLECTION (in.) DEFLECTION (in.) Compression *At these forcing...

 Open the catalog to page 4
Cylindrical Mounts - Rubber-5

Cylindrical Mounts - To 79 lbs.www.vibrationmounts.com Phone: 516.328.3662 Fax: 516.328.3365 MATERIAL: Fasteners - Steel, Zinc Plated Isolater - Natural Rubber • FOR COMPRESSION LOADS OF 33 TO 79 POUNDS (15 TO 35.8 kgf) • FOR SHEAR LOADS OF 18 TO 40 POUNDS (8.2 TO 18.1 kgf) LOAD DEFLECTION GRAPHS Deflections below the line x-x are considered safe practice for static loads; data above that line are useful for calculating deflections under dynamic loads. Catalog Number NOTE: Maximum unthreaded portion of stud does not exceed 1/16 inch (1.6 mm). ALoad Rating A, B, C, or D, see table below. *At these...

 Open the catalog to page 5
Cylindrical Mounts - Rubber-6

Cylindrical Mounts - To 86 lbs.www.vibrationmounts.com Phone: 516.328.3662 Fax: 516.328.3365 MATERIAL: Fasteners - Steel, Zinc Plated Isolator - Natural Rubber • FOR COMPRESSION LOADS OF 37 TO 86 POUNDS (16.8 TO 39 kgf) • FOR SHEAR LOADS OF 16 TO 43 POUNDS (7.3 TO 19.5 kgf) NOTE: Dimensions in ( ) are mm. NOTE: Maximum unthreaded portion of stud does not exceed 1/16 inch (1.59 mm). LOAD DEFLECTION GRAPHS Deflections below the line x-x are considered safe practice for static loads; data above that line are useful for calculating deflections under dynamic loads. DEFLECTION (in.) DEFLECTION (in.)...

 Open the catalog to page 6
Cylindrical Mounts - Rubber-7

Cylindrical Mounts - To 105 lbs.www.vibrationmounts.com Phone: 516.328.3662 Fax: 516.328.3365 MATERIAL: Fasteners - Steel, Zinc Plated Isolator - Natural Rubber FOR COMPRESSION LOADS OF 47 TO 105 POUNDS (21.3 TO 47.6 kgf) • FOR SHEAR LOADS OF 27 TO 66 POUNDS (12.2 TO 29.9 kgf) LOAD DEFLECTION GRAPHS Deflections below the line x-x are considered safe practice for q static loads; data above that line are useful for calculating deflections under dynamic loads. *At these forcing frequencies, lesser loads will yield less than 81% isolation.

 Open the catalog to page 7
Cylindrical Mounts - Rubber-8

Cylindrical Mounts - To 120 lbs.www.vibrationmounts.com Phone: 516.328.3662 Fax: 516.328.3365 MATERIAL: Fasteners - Steel, Zinc Plated Isolator - Natural Rubber • FOR COMPRESSION LOADS OF 41 TO 120 POUNDS (18.6 TO 54.4 kgf) • FOR SHEAR LOADS OF 21 TO 63 POUNDS (9.5 TO 28.6 kgf) NOTE: Dimensions in ( ) are mm. LOAD DEFLECTION GRAPHS Deflections below the line x-x are considered safe practice for static loads; data above that line are useful for calculating deflections under dynamic loads. DEFLECTION (in.) DEFLECTION (in.) Compression Forcing Frequency in Cycles per MinuteCatalog Number Maximum...

 Open the catalog to page 8
Cylindrical Mounts - Rubber-9

Cylindrical Mounts - To 123 lbs.www.vibrationmounts.com Phone: 516.328.3662 Fax: 516.328.3365 MATERIAL: Fasteners - Steel, Zinc Plated Isolator - Natural Rubber • FOR COMPRESSION LOADS OF 56 TO 123 POUNDS (25.4 TO 55.8 kgf) • FOR SHEAR LOADS OF 32 TO 63 POUNDS (14.5 TO 28.6 kgf) LOAD DEFLECTION GRAPHS Deflections below the line x-x are considered safe practice for static loads; data above that line are useful for calculating deflections under dynamic loads. Forcing Frequency in Cycles per MinuteCatalog Number Maximum Load lb. (kgf) Forcing Frequency in Cycles per Minute Catalog Number *At these...

 Open the catalog to page 9
Cylindrical Mounts - Rubber-10

Cylindrical Mounts - To 142 lbs.www.vibrationmounts.com Phone: 516.328.3662 Fax: 516.328.3365 MATERIAL: Fasteners - Steel, Zinc Plated Isolator - Natural Rubber • FOR COMPRESSION LOADS OF 56 TO 142 POUNDS (25.4 TO 64.4 kgf) • FOR SHEAR LOADS OF 32 TO 64 POUNDS (14.5 TO 29 kgf) LOAD DEFLECTION GRAPHS Deflections below the line x-x are considered safe practice for static loads; data above that line are useful for calculating deflections under dynamic loads. DEFLECTION (in.) DEFLECTION (in.) Compression Forcing Frequency in Cycles per Minute Catalog Number Maximum Load lb. (kgf) Minimum Load for...

 Open the catalog to page 10

All Advanced Antivibration Components catalogs and technical brochures

  1. Square Mounts

    3  Pages

  2. Catalog V120

    194  Pages

  3. Catalog V100

    245  Pages

  4. Catalog V110

    139  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.