Overview
The ADOS Multitronik 592 is a modular measurement, control, and warning unit designed for use with gas sensors. It can be configured for stationary or portable use and supports various sensor types via a 4-20 mA current interface or LON® field-bus. The system complies with the German VDI 2053 standard when used with the ADOS 592 TOX CO LON® gas-test sensor.

Applications
  • Garages and tunnels for gas measurement and control.
  • Workplace air monitoring to control concentration levels and prevent explosions.
  • Shelters for air quality monitoring.
  • Exhaust and waste gas measurement at test benches.
  • Monitoring liquid gas reservoirs.
  • Control of cold storage and fruit storage facilities.

Design and Operational Characteristics
The system includes gas sensors with amplifiers, input/output modules, a microcontroller-aided evaluation unit, and optional portable test units. It features a 4-line, 16-digit display for operational information and uses digital inputs/outputs for control. Communication interfaces include RS 232, RS 485, and LON® field-bus.

Technical Specifications
  • Dimensions and weight vary by version: standard, compact, and portable.
  • Protection classes range from IP 40 to IP 55.
  • Sensor inputs support 4-20 mA and LON® techniques.
  • Digital outputs support up to 230 V and 6A.
  • Battery operation exceeds 10 hours with a mains fault display.
  • Power supply ranges from 24 V to 230 V.
  • Test certificates comply with VDI 2053 standards.

Equipment Description
The system is housed in a sheet-steel enclosure with a transparent lockable door, meeting IP 54 standards. It includes power and control units for ventilators and can be equipped with or without an uninterruptible power system (UPS).
See more

Catalog excerpts

Multitronik 592 | Measurement, Control and Warning Unit for Sensors-1

tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:6.00pt "Arial", sans-serif; } .font1 { font:6.90pt "Arial", sans-serif; } .font2 { font:7.00pt "Arial", sans-serif; } .font3 { font:11.00pt "Arial", sans-serif; } .font4 { font:14.00pt "Arial", sans-serif; } .font5 { font:100.00pt "Arial Black", sans-serif; } 6 ADOS est, 1 900 InstrumentationandControl MEASUREMENT, CONTROL AND WARNING UNIT FOR SENSORS ADOS GmbH Tel: +49 (0)2 41 / 97 69 - 0 ^^^m Instrumentation and Control ■ Fax: +49 (0)2 41 / 97 69 - 16 P.O. Box 500 444 52088 Aachen Օ FRG ■ E-Mail: [email protected] Trierer Strasse 23-25 52078 Aachen Օ FRG ■ www.ados.de

 Open the catalog to page 1
Multitronik 592 | Measurement, Control and Warning Unit for Sensors-2

tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:3.75pt "Arial", sans-serif; } .font1 { font:5.00pt "Arial", sans-serif; } .font2 { font:7.00pt "Arial", sans-serif; } .font3 { font:9.00pt "Arial", sans-serif; } .font4 { font:11.00pt "Arial", sans-serif; } .font5 { font:14.25pt "Arial", sans-serif; } .font6 { font:17.00pt "Arial", sans-serif; } MEASUREMENT, CONTROL AND WARNING UNIT FOR SENSORS Multitronik 592 ADOS est, 1 900 Application lomaines d'utilisation ADOS Multitronik 592 is a modular-constructed measure-ment, control and warning unit, designed for universal use with gas...

 Open the catalog to page 2
Multitronik 592 | Measurement, Control and Warning Unit for Sensors-3

tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:3.75pt "Arial", sans-serif; } .font1 { font:5.00pt "Arial", sans-serif; } .font2 { font:7.00pt "Arial", sans-serif; } .font3 { font:9.00pt "Arial", sans-serif; } .font4 { font:11.00pt "Arial", sans-serif; } .font5 { font:14.25pt "Arial", sans-serif; } .font6 { font:17.00pt "Arial", sans-serif; } MEASUREMENT, CONTROL AND WARNING UNIT FOR SENSORS Multitronik 592 ADOS est, 1 900 Design and Operational Characteristics All information significant to opration is displayed in clear text on a 4-line, 16-digit display.This information includes...

 Open the catalog to page 3
Multitronik 592 | Measurement, Control and Warning Unit for Sensors-4

tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:3.75pt "Arial", sans-serif; } .font1 { font:5.00pt "Arial", sans-serif; } .font2 { font:7.00pt "Arial", sans-serif; } .font3 { font:9.00pt "Arial", sans-serif; } .font4 { font:11.00pt "Arial", sans-serif; } .font5 { font:14.25pt "Arial", sans-serif; } .font6 { font:17.00pt "Arial", sans-serif; } MEASUREMENT, CONTROL AND WARNING UNIT FOR SENSORS Multitronik 592 ADOS est, 1 900 echnical Data Version .standard" Sensor inputs: 4-20 mA current interface for Connecting sensors using two- or three-wire techniques LON® four-wire techniques...

 Open the catalog to page 4

All ADOS GmbH, Mess- und Regeltechnik catalogs and technical brochures

  1. Flex ADOS 914

    2  Pages

  2. GWA 2000

    2  Pages

  3. MWS 906 CP

    2  Pages

  4. GW 399

    2  Pages

  5. MWS 903

    2  Pages

  6. TOX 592

    2  Pages

  7. GTR 210

    4  Pages

  8. Biogas 905

    2  Pages

  9. Biogas 401

    2  Pages

  10. ITR 504

    2  Pages

  11. MWS 897

    2  Pages

  12. MWS 906

    2  Pages

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.