MRF102
1Pages

{{requestButtons}}

Catalog excerpts

MRF102 - 1

Warning when the current exceed 80% ADELBus I/O for driverer, monotoring and Configuration. ADELViewSystem for programming and Control the device Sequential Output Switch start. Reduce Inrush Current 2 Load Output, with adjustable current range 1..10A Power Boost 150% Two output switchable in Parallel (max 15A) Power limitation of the output to 100 VA, in according to NEC Class 2 Monitoring for trigger switch off output for max Current or min Voltage on the channel Alarm Output Open Collector DIN Rail and Wall Mount General Electronic Circuit Breacker Fuse, for protections about Overload and Short Circuit, Two channel electronic circuit with active current limitation for output load. It can operate in the field 12 and 24Vdc, for installation in DIN rail and Wall Mount. AUX1: connection 2 pin AMP 1: as ADELBus for Driving, Monitoring, Configuring 2: Out Alarm for For SwitchOff Output - Common Signaling for disconnection Last Output - Single Channel: Current, set current threshold, Status On/Off - Reason for Output disconnection Connection for monitoring device: Configuration Aux1 Diagnosis Technical Data Input Data Supply voltage / at DC / Rated value DC Input Voltage range (Vdc) Overvoltage overload capability Input current / at rated input voltage 12 - 24 V / Rated Value Maximum current consumption Required Back Up Fuse Input Voltage Reset Output Output Data Voltage curve / at output Drop Out Number of outputs Output current / up to 60 °C / per output / rated value Adjustable switch Off out current Type of response value setting Parallel switching of outputs Bridging of equipment’s Start Up Surge voltage shutdown load circuit Max Capacitive Load Rated Surge Voltage 12 – 24 V 8 – 32 V 35 V 20 A max (30A peak max 10 sec) Xxx A (12 VDC) - Xxx A (24 VDC) Not required. Integrated failsafe element (internal fuse) 7 …32 Vdc Controlled DC voltage 0.2 V 2 10 A 1 …10A via Blink code Led Yes No < 0.5 sec. >32 Vdc 50.000 uF 0.5 KV Efficiency Efficiency Power loss [W] (typ) Power dissipation 97% 17W (Nominal Operation) 0.9 W (No Load operation) Switching - off per output Iout = 1.0 ...1.5 x set value Iout = 1.5 ...1.8 x set value Iout = 1.2 ...2 x set value Iout > 2 x set value Iout > set value and Vin < 15% (24V); (12V) Turn On Output after Switch Off Waiting time after switch off Out Protection and Monitoring Internal Fuse protection type Dielectric strength Display version switch-off after approx. 5 s switch-off after approx. 1 s switch-off after approx. 0,1 s switch-off after approx. 0,03 s switch-off after approx. 0,03 s - Hiccup Mode - Manual Reset - By Press Button - 5 sec (Hover load / Short Circuit) 16A per output (not replaceable) Max 32 Vdc (on Load Circuit) Three-color LED per output: green LED for "Output switched through"; yellow LED for "Output switched off manually"; red LED for "Output switched off due to overcurrent" Input 12 or 24V Input 0V Outputs Signal Output: Ambient Conditions Nominal Temperature operation Ambient Temperature operation Ambient Temperature Storage Humidity at 25 °C, no condensation Vibration (operation) IEC 60068-2-6 Altitude: 0 to 2 000m - 6560 to 20 000ft General Data Protection Class (EN/IEC 60529) Reliability: MTBF IEC 61709 Protection class Housing material Foot latch material Screw type connection IP20 > 700.000 h (Automatically Switch Off Beck Light after 30 sec) III Polycarbonate Plastic POM 0.2 - 2.5 mm2 (24 – 12 AWG) 0.6 - 0.8 Nm 18 x 90 x 61 0.1 kg approx. Dimension (w-h-d) mm Weight Immunity and Emission The CE mark in conformity to EMC 2014/30/EU: Electromagnetic Compatibility Directive; 2014/35/EU: Low Voltage Directive; ROHS 2011/65/EU: Restriction of the use of certain Hazardous Substances in Electrical and Electronic Equipment (RoHS), as amended by 2015/863/EU • EMC Immunity: EN61000-6-2 • EMC Emission: EN61000-6-3, EN 55022 ClassB Electrical Safety for mounting According to: • Electrical Equipment for Machinery EN 60204 • Electrical safety (of information technology equipment) IEC/EN EN62368-1. • Safety requirements for electrical equipment for measurement, control and Laboratory use IEC/EN 61010 RTConn: connector cable for the connection to AUX1. It is possible drive the device true this cable true the net ADELBus.

Open the catalog to page 1

All ADELSYSTEM catalogs and technical brochures

  1. CBI2501224A

    2 Pages

  2. DFX60110

    1 Pages

  3. BAT12Wh

    2 Pages

  4. DFX6024A

    1 Pages

  5. DFX6012A

    1 Pages

  6. DFX1512A

    1 Pages

  7. DFX1524A

    1 Pages

  8. CBI6024A

    1 Pages

  9. CBI6012A

    1 Pages

  10. CB6024A

    1 Pages

  11. CB6012A

    1 Pages

  12. FLEX50048A

    1 Pages

  13. FLEX28048A

    1 Pages

  14. FLEX17048A

    1 Pages

  15. FLEX28012A

    1 Pages

  16. FLEX17012A

    1 Pages

  17. FLEX6012A

    1 Pages

  18. FLEX28024B

    1 Pages

  19. FLEX50024B

    1 Pages

  20. FLEX17024B

    1 Pages

  21. FLEX9024B

    1 Pages

  22. FLEX50024A

    1 Pages

  23. FLEX28024A

    1 Pages

  24. FLEX17024A

    1 Pages

  25. FLEX9024A

    1 Pages

  26. FLEX6024A

    1 Pages

  27. DPY353

    1 Pages

  28. DPY351

    2 Pages

  29. CB2420A

    1 Pages

  30. CB2410AC

    1 Pages

  31. CB1235A

    1 Pages

  32. CB243A

    1 Pages

  33. CB304A

    1 Pages

  34. CB363A

    1 Pages

  35. CB123A/48

    1 Pages

  36. CB1210A

    1 Pages

  37. CB123A

    1 Pages

  38. CB122410A

    1 Pages

  39. CB12245AJ

    1 Pages

  40. CB12245A

    1 Pages

  41. BAT12VRLA

    1 Pages

  42. BAT7.2VRLA

    1 Pages

  43. BAT3.4VRLA

    1 Pages

  44. BAT1.2VRLA

    1 Pages

  45. CBI2801224A

    2 Pages

  46. CBI4810A

    1 Pages

  47. CBI2420AP

    1 Pages

  48. CBI2420A

    1 Pages

  49. CBI1235A

    1 Pages

  50. CBI485A

    1 Pages

  51. CBI2410A

    1 Pages

  52. CBI245A

    1 Pages

  53. CBI243A

    1 Pages

  54. CBI1210A

    1 Pages

  55. CBI126A

    1 Pages

  56. CBI123A

    1 Pages