Input: single-phase: 115 – 230 Vac Output: 24 Vdc 50°C RoHS Efficiency up to 85% Strong overload without switch-off Flexible Power continuity: from 36 to 72 W DIN Rail Mountable Extremely small size 3 Years warranty Features Input Data Nominal Input Voltage (2 x Vac) Input Voltage range (Vac) Inrush Current (Vn and In Load) Frequency Input Current (115 – 230 Vac) Internal Fuse External Fuse (recommended) Norms and certifications 115 – 230 Vac 90 – 264 19 A 5 msec. 47 – 63 Hz 1 – 0.7 A T4A 6 A (MCB curve B) The CE mark in According to EMC 2014/30/UE and Low voltage directive 2014/35/UE. 24 Vdc 22 – 27 Vdc 50.000F 1.5 sec. (max) 2 A (115) 3 A (230) 1.5 A (115) 2.5 A (230) 3.5 A 3 min. Imax=In50°Cx(1.8 - 2.2) 7A Typ. 20 msec 80 mVpp 85 % Yes. Shut-down output and automatic restart. Yes, Continuous Mode 13 Yes, Continuous Mode Yes (typ. 35 Vdc) Yes Output Data Output Voltage (Vn) Factory Setting 3% Adjustment range (Vadj) Start up with Strong Load (capacitive load) Turn-On delay after applying mains voltage Continuous Current at 24 V < 40°C (In) Continuous Current at 24 V < 50°C (In) Power Boost Current at 24 Vdc 50°C(In) Current max. Overload 4Vdc (permanent) Max current Short Circuit (Icc) Hold-up Time ( min. Vac) Vn In 40°C Residual Ripple Efficiency Over temperature Protection Short-circuit protection Max Dissipation Power at Vn In 40°C Over Load protection Over Voltage Output protection Parallel connection Electrical Safety In compliance to UL508. EN IEC 61010-2-201:2018 According to IEC/EN 60950 (VDE 0805) e EN 50178 (VDE 0160) for assembling device. The unit must be installed according to IEC/EN 60950.Input / Output separation: SELV EN60950-1 6 Edition, and PELV EN 60204-1. Double or reinforced insulation. EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN61000-6-2 Standards Conformity EN 60204-1 Safety of Electrical Equipment Machines Output derating Curve Continuous Load % 160 140 120 100 80 60 40 20 0 -10 Climatic Data Ambient Temperature operation Ambient Temperature Storage Humidity at 25 °C, no condensation General Data Isolation Voltage (In / Out) Isolation Voltage (In / PE) Isolation Voltage (Out / PE) Protection Class (EN/IEC 60529) Reliability: MTBF IEC 61709 Pollution Degree Environment Connection Terminal Blocks Screw Type Protection class Dimension (w-h-d) Weight 3000 Vac 1605 Vac 500 Vac IP 20 > 500.000 h 2 2,5 mm2 (24 – 14 AWG) I with PE connected 50x120x50 mm 0.3 kg approx.
Open the catalog to page 12 Pages
2 Pages
1 Page
2 Pages
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
2 Pages
1 Page
12 Pages
2 Pages
2 Pages
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
2 Pages
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page