Catalog excerpts
Input: 115 – 230 Vac Output: 12 Vdc 60°C Flexible Power continuity :from 36 to 72 W Efficiency up to 88% Strong overload without switch-off, up to 50% RoHS “Power Good” Relay Tree mode of output protections: 1) Hiccup mode 2) Continuous Out Mode 3) Manual Reset DIN Rail Mountable Extremely small size 3 Years warranty Features Input Data Nominal Input Voltage (2 x Vac) Input Voltage range (Vac) Inrush Current (Vn and In Load) I2t Frequency Input Current (115 – 230 Vac) Internal Fuse External Fuse (recommended) Norms and certifications 115 – 230 Vac 90 – 264 7 A 5 msec. 47 – 63 Hz 6% 1 – 0.7 A T4A 6 A (MCB curve B) The CE mark in According to EMC 2014/30/UE and Low voltage directive 2014/35/UE. 12 Vdc 10 – 15.5 Vdc 50.000F 1.5 sec. (max) 4 A (115) 6 A (230) 3 A (115) 5 A (230) 7 A up to 3 min. 6 A up to 3 min. Imax=In50°Cx(1.8 - 2.2) 10 A Typ. 20 msec 80 mVpp 88 % Yes. Shut-down output and automatic restart. Yes, Continuous Mode 6 Yes, Continuous Mode Yes (typ. 30 Vdc) Yes Output Data Output Voltage (Vn) Factory Setting 3% Adjustment range (Vadj) Start up with Strong Load (capacitive load) Turn-On delay after applying mains voltage Continuous Current at 12 V up to 40°C (In) Continuous Current at 12 V up to 50°C (In) Power Boost Current at 12 Vdc 50°C(In) Power Boost Current at 15 Vdc 50°C(In) Current max. Overload 4Vdc (permanent) Max current Short Circuit (Icc) Hold-up Time ( min. Vac) 12Vdc 5A Residual Ripple Efficiency Over temperature Protection Short-circuit protection Dissipation power load max (W) Over Load protection Over Voltage Output protection Parallel connection Electrical Safety In compliance to UL508. EN IEC 61010-2-201:2018 According to IEC/EN 60950 (VDE 0805) e EN 50178 (VDE 0160) for assembling device. The unit must be installed according to IEC/EN 60950.Input / Output separation: SELV EN60950-1 6 Edition, and PELV EN 60204-1. Double or reinforced insulation. EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN61000-6-2 Standards Conformity EN 60204-1 Safety of Electrical Equipment Machines Climatic Data Ambient Temperature operation Ambient Temperature Storage Humidity at 25 °C, no condensation General Data Isolation Voltage (In / Out) Isolation Voltage (In / PE) Isolation Voltage (Out / PE) Protection Class (EN/IEC 60529) Reliability: MTBF IEC 61709 Pollution Degree Environment Connection Terminal Blocks Screw Type Protection class Dimension (w-h-d) Weight 3000 Vac 1605 Vac 500 Vac IP 20 > 500.000 h 2 2,5 mm (24 – 14 AWG) I with PE connected 50x120x50 mm 0.3 kg approx.
Open the catalog to page 1All ADELSYSTEM catalogs and technical brochures
-
CBI2501224A
2 Pages
-
DFX60110
1 Pages
-
BAT12Wh
2 Pages
-
DFX6024A
1 Pages
-
DFX6012A
1 Pages
-
DFX1512A
1 Pages
-
DFX1524A
1 Pages
-
CBI6024A
1 Pages
-
CBI6012A
1 Pages
-
CB6024A
1 Pages
-
CB6012A
1 Pages
-
FLEX50048A
1 Pages
-
FLEX28048A
1 Pages
-
FLEX17048A
1 Pages
-
FLEX28012A
1 Pages
-
FLEX17012A
1 Pages
-
FLEX28024B
1 Pages
-
FLEX50024B
1 Pages
-
FLEX17024B
1 Pages
-
FLEX9024B
1 Pages
-
FLEX50024A
1 Pages
-
FLEX28024A
1 Pages
-
FLEX17024A
1 Pages
-
FLEX9024A
1 Pages
-
FLEX6024A
1 Pages
-
DPY353
1 Pages
-
DPY351
2 Pages
-
MRF102
1 Pages
-
DC-UPS Catalogue
12 Pages
-
POWER SUPPLY FLEX Catalogue
2 Pages
-
BATTERY HOLDER 12V
2 Pages
-
CB2420A
1 Pages
-
CB2410AC
1 Pages
-
CB1235A
1 Pages
-
CB243A
1 Pages
-
CB304A
1 Pages
-
CB363A
1 Pages
-
CB123A/48
1 Pages
-
CB1210A
1 Pages
-
CB123A
1 Pages
-
CB122410A
1 Pages
-
CB12245AJ
1 Pages
-
CB12245A
1 Pages
-
BAT12VRLA
1 Pages
-
BAT7.2VRLA
1 Pages
-
BAT3.4VRLA
1 Pages
-
BAT1.2VRLA
1 Pages
-
CBI2801224A
2 Pages
-
CBI4810A
1 Pages
-
CBI2420AP
1 Pages
-
CBI2420A
1 Pages
-
CBI1235A
1 Pages
-
CBI485A
1 Pages
-
CBI2410A
1 Pages
-
CBI245A
1 Pages
-
CBI243A
1 Pages
-
CBI1210A
1 Pages
-
CBI126A
1 Pages
-
CBI123A
1 Pages