Catalog excerpts
Input Data Nominal Input Voltage (2 x Vac) Manual select Input from 230 to 400-500 Input Voltage range: (230) (400-500) Inrush Current (Vn and In Load) Frequency Input Current (230 – 400 – 500 Vac) Internal Fuse External Fuse (recommended) The CE mark in According to EMC 2014/30/UE and Low voltage directive 2014/35/UE. Electrical Safety Output Data Output Voltage (Vn) Factory Setting 3% Adjustment range (Vadj) Start up with Strong Load (capacitive load) Turn-On delay after applying mains voltage Continuous Current at 24 V < 40°C (In) Continuous Current at 24 V < 50°C (In) Continuous Current at 24 V < 60°C (In) Power Boost Current at 24 Vdc 60°C(In) Current max. Overload 4Vdc (permanent) Maximum Short Circuit Current Icc Hiccup mode: Max 2 sec. Continuous Mode Hold-up Time ( min. Vac) ) Vn In 40°C Residual Ripple Efficiency Over temperature Protection Short-circuit protection Max Dissipation Power at Vn In 40°C Over Load protection Over Voltage Output protection Parallel connection Power Good Contact rating (EN60947.4.1): Max. DC1: 30 Vdc 1 A; AC1: 60 Vac 1A Min.1mA at 5 Vdc 24 Vdc 22 – 27 Vdc 50.000F 1 sec. (max) 7.5 A 6A 5A In (60°C) x 1.5 3 min. Imax=In60°Cx(1.8 - 2.2) 16 A Typ. 20 msec 80 mVpp 89 % Yes. Shut-down output and automatic restart. 1° Manual Reset 2° Hiccup Mode 3° Continuous Out Mode 22 W Yes Yes (typ. 35 Vdc) Yes Resistive load Min permissive load Climatic Data Ambient Temperature operation Ambient Temperature Storage Humidity at 25 °C, no condensation General Data Isolation Voltage (In / Out) Isolation Voltage (In / PE) Isolation Voltage (Out / PE) Protection Class (EN/IEC 60529) Reliability: MTBF IEC 61709 Pollution Degree Environment Connection Terminal Blocks Screw Type Protection class Dimension (w-h-d) Weight Input: 230 – 400 – 500 Vac Output: 24 Vdc 60°C Efficiency up to 89% Strong overload without switch-off, up to 50% Flexible Power continuity: from 120 to 180 W “Power Good” Relay Three mode of output protections: 1) Hiccup mode 2) Continuous Out Mode 3) Manual Reset DIN Rail Mountable Extremely small size 3 Years warranty In compliance to UL508. EN IEC 61010-2-201:2018 According to IEC/EN 60950 (VDE 0805) e EN 50178 (VDE 0160) for assembling device. The unit must be installed according to IEC/EN 60950.Input / Output separation: SELV EN60950-1 and PELV EN 60204-1. Double or reinforced insulation. Standards Conformity EN 60204-1 Safety of Electrical Equipment Machines Output derating Curve Continuous Load % 160 140 120 100 80 60 40 20 0 -10 Output Voltage vs. Output Current, typ. Out Voltage 28 24 20 16 12 8 4 0 3000 Vac 1605 Vac 500 Vac IP 20 > 500.000 h 2 2,5 mm2 (24 – 14 AWG) I with PE connected 55x110x105 mm 0.60 kg approx
Open the catalog to page 1All ADELSYSTEM catalogs and technical brochures
-
CBI2501224A
2 Pages
-
DFX60110
1 Pages
-
BAT12Wh
2 Pages
-
DFX6024A
1 Pages
-
DFX6012A
1 Pages
-
DFX1512A
1 Pages
-
DFX1524A
1 Pages
-
CBI6024A
1 Pages
-
CBI6012A
1 Pages
-
CB6024A
1 Pages
-
CB6012A
1 Pages
-
FLEX50048A
1 Pages
-
FLEX28048A
1 Pages
-
FLEX17048A
1 Pages
-
FLEX28012A
1 Pages
-
FLEX17012A
1 Pages
-
FLEX6012A
1 Pages
-
FLEX28024B
1 Pages
-
FLEX50024B
1 Pages
-
FLEX9024B
1 Pages
-
FLEX50024A
1 Pages
-
FLEX28024A
1 Pages
-
FLEX17024A
1 Pages
-
FLEX9024A
1 Pages
-
FLEX6024A
1 Pages
-
DPY353
1 Pages
-
DPY351
2 Pages
-
MRF102
1 Pages
-
DC-UPS Catalogue
12 Pages
-
POWER SUPPLY FLEX Catalogue
2 Pages
-
BATTERY HOLDER 12V
2 Pages
-
CB2420A
1 Pages
-
CB2410AC
1 Pages
-
CB1235A
1 Pages
-
CB243A
1 Pages
-
CB304A
1 Pages
-
CB363A
1 Pages
-
CB123A/48
1 Pages
-
CB1210A
1 Pages
-
CB123A
1 Pages
-
CB122410A
1 Pages
-
CB12245AJ
1 Pages
-
CB12245A
1 Pages
-
BAT12VRLA
1 Pages
-
BAT7.2VRLA
1 Pages
-
BAT3.4VRLA
1 Pages
-
BAT1.2VRLA
1 Pages
-
CBI2801224A
2 Pages
-
CBI4810A
1 Pages
-
CBI2420AP
1 Pages
-
CBI2420A
1 Pages
-
CBI1235A
1 Pages
-
CBI485A
1 Pages
-
CBI2410A
1 Pages
-
CBI245A
1 Pages
-
CBI243A
1 Pages
-
CBI1210A
1 Pages
-
CBI126A
1 Pages
-
CBI123A
1 Pages