Input Data Nominal Input Voltage (2 x Vac) Manual select Input from 115 to 230 Input Voltage range: (Vac) Inrush Current (Vn and In Load) Frequency Input Current (230 – 400 – 500 Vac) Internal Fuse External Fuse (recommended) The CE mark in According to EMC 2014/30/UE and Low voltage directive 2014/35/UE. Electrical Safety Output Data Output Voltage (Vn) Factory Setting 3% Adjustment range (Vadj) Start up with Strong Load (capacitive load) Turn-On delay after applying mains voltage Continuous Current at 12 V < 40°C (In) Continuous Current at 12 V < 50°C (In) Continuous Current at 12 V < 60°C (In) Power Boost Current at 12 Vdc 60°C(In) Current max. Overload 4Vdc (permanent) Maximum Short Circuit Current Icc Hiccup mode: Max 2 sec. Continuous Mode Hold-up Time ( min. Vac) ) 12Vdc 5A Residual Ripple Efficiency Over temperature Protection Short-circuit protection Dissipation power load max (W) Over Load protection Over Voltage Output protection Parallel connection Power Good Contact rating (EN60947.4.1): Max. DC1: 30 Vdc 1 A; AC1: 60 Vac 1A Min.1mA at 5 Vdc Input: 115 – 230 Vac Output: 12 Vdc 60°C Flexible Power continuity: from 120 to 180 W Efficiency up to 91% Strong overload without switch-off, up to 50% “Power Good” Relay Tree mode of output protections: 1) Hiccup mode 2) Continuous Out Mode 3) Manual Reset DIN Rail Mountable Extremely small size 3 Years warranty 12 Vdc 12 – 15 Vdc 50.000F 1 sec. (max) 14 A 12 A 10 A In (60°C) x 1.5 3 min. Imax=In60°Cx(1.8 - 2.2) 20 A Typ. 20 msec 80 mVpp 91 % Yes. Shut-down output and automatic restart. 1° Manual Reset 2° Hiccup Mode 3° Continuous Out Mode 17 Yes Yes (typ. 35 Vdc) Yes In compliance to UL508. EN IEC 61010-2-201:2018 According to IEC/EN 60950 (VDE 0805) e EN 50178 (VDE 0160) for assembling device. The unit must be installed according to IEC/EN 60950.Input / Output separation: SELV EN60950-1 and PELV EN 60204-1. Double or reinforced insulation. Standards Conformity EN 60204-1 Safety of Electrical Equipment Machines Resistive load Min permissive load Climatic Data Ambient Temperature operation Ambient Temperature Storage Humidity at 25 °C, no condensation General Data Isolation Voltage (In / Out) Isolation Voltage (In / PE) Isolation Voltage (Out / PE) Protection Class (EN/IEC 60529) Reliability: MTBF IEC 61709 Pollution Degree Environment Connection Terminal Blocks Screw Type Protection class Dimension (w-h-d) Weight 3000 Vac 1605 Vac 500 Vac IP 20 > 500.000 h 2 2,5 mm2 (24 – 14 AWG) I with PE connected 55x110x105 mm 0.60 kg approx.
Open the catalog to page 12 Pages
2 Pages
1 Page
2 Pages
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
2 Pages
1 Page
12 Pages
2 Pages
2 Pages
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
2 Pages
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page