Extremely small size Safety 100 – 240 – 277 Vac 85 – 305 95 – 370 Vdc 45 – 65 Hz 5% 0 Hz 0.3 A (120 Vac) 0.2 A (230 Vac) 15 A 5 msec. >15 msec (120 Vac) >30 msec (230 Vac) 0.5 A 6 A curve B 6A curve B or 2A curve C Output Data 24 Vdc 3% 22.5 – 28 Vdc 30.000F 1 sec. (max) 0.65 A Derating 2%/K 1.1 A 3 min. 1.3 A 1.3 A 100 mVss 150 mVss No Yes (max four device) Yes Efficiency Efficiency at Vout rated, Iout rated, approx. Power loss at Vout rated, Iout rated, approx. Power loss [W] during no-load operation maximum Reliability: MTBF at 40°C IEC 61709 DIN Rail and wall mounted – IP20 Output Voltage isolated DC Voltage (Vn) Adjustment range (Vadj) Start up with Strong Load (capacitive load) Turn-On delay after applying mains voltage Continuous Current -25 - +55°C In Continuous Current +55 - +70°C In Power Boost Current at 24 Vdc 55° C In Max Short Circuit current (Icc) Enduring Short Circuit current RMS max. Residual Ripple (with nominal value) Peak Parallel connection to increase power Series Connection Redundancy Connection Overload, overvoltage and short-circuit protection Internal Fuse (slow – blow, Internal) External Fuse (recommended) External Circuit Breaker (recommended) Wide temperature range: -25 to 70°C Inrush Current limitation (Vn and In Load) I2t Hold-up Time (Typ.) Nominal Input Voltage (2 x Vac) AC Input Voltage range (Vac) DC Input Range AC Frequency DC Frequency Current consumption (Approx..) Flexible power continuity up to 20 W Input Data Wide input range: 100 – 240 Vac For industrial and residential applications Primary/secondary isolation Pollution Degree Environment Insulation voltage (IN/OUT) Insulation voltage (Input / Earth, PE) Insulation voltage (Out Load / Earth, PE) Galvanic isolation to: EN 62368 and EN 50178 Degree of protection (EN 60529) Yes 2 4000 Vac 2000 Vac 500 Vac Safety extra-low output voltage Uout IP20 Norms and Certifications CE mark in conformity to EMC 2014/30/EU: Electromagnetic Compatibility Directive; 2014/35/EU: Low Voltage Directive; ROHS 2011/65/EU: Restriction of the use of certain Hazardous Substances in Electrical and Electronic Equipment (RoHS), as amended by 2015/863/EU; EMC Immunity: EN610006-2; EMC Emission: EN61000-6-3, EN 55022 Class B Approval CE mark UL/cUL (CSA) approval Mechanics Data Screw type connection Connections Supply Input: L, N: 1 phase Connections Output: +, Protection class MTBFat 40°C Housing material Dimension (WxHxD) DIN 43880 Weight (approx.) Closed-loop control Dynamic mains compensation (Vin rated ±15 %), max. Dynamic load smoothing (Iout: 10/90/10 %), Uout ± typ. Load step setting time 10 to 90%, typ. Load step setting time 90 to 10%, typ. Protection and monitoring Output over voltage protection Short-circuit protection Over Load capability Over Voltage Output protection Status output voltage OK Hiccup. Shut-down output and automatic restart. Hiccup. Shut-down output and automatic restart. 150% In typ. 200ms Yes (typ. 35 Vdc) Green LED Environmental Conditions Ambient Temperature operation Ambient Temperature Storage Humidity at 25 °C in acc. to EN 60721 Vibration (operation) IEC 60068-2-6 -25 up to +70 °C -40 up to +85 °C 95 % no condensation <15 Hz, amplitude 2.5mm <15Hz-150Hz, 2.3g 90 min. 30g in all directions
Open the catalog to page 12 Pages
2 Pages
1 Page
2 Pages
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
2 Pages
1 Page
12 Pages
2 Pages
2 Pages
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
2 Pages
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page