CBI6024A - 1

Input: Single-phase 115 – 230 - 277 Vac Output Selectable Load:24Vdc 2.5A Output Battery charging:24 Vdc 2.5A Suited for the following battery types: Open Lead Acid, Sealed Lead Acid, lead Gel, Ni-Cd, Li-Ion Automatic diagnostic of battery status, Battery Life Test function (internal Battery Impedance) Charging curve IUoU, constant voltage and current Four charging levels: Boost, Bulk, Trickle, Recovery Protected against short circuit and inverted polarity Signal output: for battery Fault, Mains or Back-UP Ethernet: SNMP V3, Modbus TCP/IP, HTTPS DIN rail and Wall mount Power Management: Thanks to the All In One units (DC-UPS), it will be possible to optimize power management. The available power is automatically allocated between load and battery, supplying power to the load is the first priority of the unit thus it is not necessary to double the power, because also the power going to the battery will go to the load if the load so requires. The maximum available current on the load output is 3 times the value of the device rated current In. Battery Care: it’s the concept base on algorithms that implement rapid and automatic charging, four state of charge, battery charge optimization during time, flat batteries recovery and real time diagnostic during installation and operation. The Real Time Auto-diagnostic system, monitoring battery faults such as, battery Sulfated, elements in short circuit, accidental reverse polarity connection, disconnection of the battery, they can easily be detected and removed by help of Blink Code of Diagnosis Led; during the installation and after sell. The continuous monitoring of battery efficiency, reduces battery damage risk and allows a safe operation in permanent connection. Each device is suited for all battery types, by means of jumpers it is possible setting predefined curves for Open Lead Acid, Sealed Lead Acid, Gel, NiCd(option). They are programmed for two charging levels, boost and trickle, but they can be changed to single charging level by the user. A rugged casing for DIN rail mounting, IP20 protection degree. They are extremely compact and cost effective. The platform communication for ADELSYSTEM devices, allows the connection of all components in a simple but very powerful way, Ethernet. A protocol communication based on MODbus TCP/IP or SNMP technology. You can select any of the two buses depending on the application. It allows to communicate with all the accessories provided by ADELSYSTEM and to develop an independent system for electrical continuity. At the same time, it allows monitoring and control all parameters in the system, even from the other side of the world, by means of application tools on the cloud. ADELSYSTEM allows you to implement very simple but sophisticated monitoring and control for your energy system and opens your mind to new ways to approach your applications. ADELSYSTEM allows you to implement very simple but sophisticated monitoring and control for your energy system and opens your mind to new ways to approach your applications. The CE mark in conformity to EMC 2014/30/EU: Electromagnetic Compatibility Directive; 2014/35/EU: Low Voltage Directive; ROHS 2011/65/EU: Restriction of the use of certain Hazardous Substances in Electrical and Electronic Equipment (RoHS), as amended by 2015/863/EU. EMC Immunity: EN61000-6-2;EMC Emission: EN61000-6-3. According to: Electrical Equipment for Machinery EN 60204; Electrical safety (of information technology equipment) IEC/EN EN62368-1. Climatic Data Ambient temperature (operation) De Rating Ta > 50°C Ambient temperature Storage Humidity at 25 °C no condensation Cooling General Data Insulation voltage (IN/OUT) Insulation voltage (input / ground) Insulation voltage (Output / ground) Protection Class (EN/IEC 60529) Reliability: MTBF IEC 61709 Pollution Degree Environment Connection Terminal Blocks screw Type Connection Terminal Protection class Dimensions (w-h-d) (Approx.) Weight (Approx.) Input Data Nominal Input Voltage (2 x Vac) Input Voltage range (Vac) Inrush Current (Vn – In nom. Load) I2t Frequency Input Current (115 – 230 Vac) Internal fuse (not replaceable) External Fuse (recommended) MCB curve B Load Output 24 Vdc (jumper selection) Output voltage (at In) Nominal Current In Continuous current (without battery) Iload= In Continuous current ( With battery) Iload= In+ Ibatt Max. Output Load (Main with Battery) Iload= In+ Ibatt (4 sec.) Max. current Output Load (Back Up)Iload (4 sec.) Output On/Off Push Button "Start from Battery without main" Time Buffering; (switch output off without main input) Battery Output Output Voltage Battery Boost-Fast charge Configuration 25°C (V/cell). Jumper Configuration battery type Float Charge Configuration 25°C (V/cell) Jumper Configuration battery type Min. Time Boost/Fast charge (Typ. at IN) Max. Time Bulk charge (Typ. at IN) Min. Time Bulk charge (Typ. At IN) Trickle Charge: Depend on Battery type (V cell) Ni-Cd: Trickle – Boos charging V/cell (20 cell) Recovery Charge End of charging Current (Bulk & Absorption charge) Charging current max Ibatt Charging current limiting Iadj Reverse battery protection Sulfated battery check Detection of element in short circuit Quiescent Current on the battery Charging Curve automatic: IUoU Fast Charge Threshold alarm Battery almost flat Protections against total discharge Follow the Out Load Lead Acid: 2.4 NiCd:1.51; Li-ion: 3.65 Lead Acid: 2.23; 2.25;2.27;2.3 NiCd:1.4; Li-ion: 3.45 1 min. 15 h 1 min. 2.23;2.25;2.27;2.3 1.4V – 1-5V 2 -10 V 6% of current limiting In ± 5% 10 ÷ 100 % / Ibat Yes Yes (by Jumper) Yes £ 5 mA 4 stage Boost /Float 20 – 21 Vdc batt 19 – 20 Vdc batt Signal Output (Open Collector) Main or Backup Power (Sink 20 mA max) Fault Battery / System (Sink 20 mA max) Rectifier Failure “Device” (Sink 20 mA max) Signal Input Battery Start 22 - 28.8 Vdc (17Vdc Ni-Cd) 1.1 x In A ± 5% 2.5 A 2 x In 3 x In max. (A) 2 x In max. Drive by: HRxxxxxx Yes 0.5;2;5;10;15; 20; 30; 45;60;∞ Temp. Comp. Battery (with external probe) ON: 0 Vdc OFF: Vout (Alarm) ON: 0 Vdc OFF: Vout (Alarm) ON: 0 Vdc OFF: Vout (Alarm) Terminal Block Push Button RJ temp (RJ11) Digital Input / Output Communication Protocol (Ethernet) ADELBus TCP/IP - SNMP V3 - HTTPS CAN General Output Data Output Voltage 24 Vdc Nominal current In Turn-On delay after applying mains voltage Start up with Strong Load (capacitive load) Efficiency (at 50% of rated current) Dissipation power load max (W) Start from Battery only, without main Short-circuit protection Over Load protection Over Voltage Output protection Overheating Thermal protection 24 Vdc 2.5 A± 5% 1 sec. (max) Yes, Unlimited ³ 90 % 6 Push Button Yes Yes Yes (typ. 35 Vdc) Yes

Open the catalog to page 1

All ADELSYSTEM catalogs and technical brochures

  1. DFX6024A

    1 Pages

  2. DFX6012A

    1 Pages

  3. DFX1512A

    1 Pages

  4. DFX1524A

    1 Pages

  5. CBI6012A

    1 Pages

  6. CB6024A

    1 Pages

  7. CB6012A

    1 Pages

  8. FLEX50048A

    1 Pages

  9. FLEX28048A

    1 Pages

  10. FLEX17048A

    1 Pages

  11. FLEX28012A

    1 Pages

  12. FLEX17012A

    1 Pages

  13. FLEX6012A

    1 Pages

  14. FLEX28024B

    1 Pages

  15. FLEX50024B

    1 Pages

  16. FLEX17024B

    1 Pages

  17. FLEX9024B

    1 Pages

  18. FLEX50024A

    1 Pages

  19. FLEX28024A

    1 Pages

  20. FLEX17024A

    1 Pages

  21. FLEX9024A

    1 Pages

  22. FLEX6024A

    1 Pages

  23. DPY353

    1 Pages

  24. DPY351

    2 Pages

  25. MRF102

    1 Pages

  26. CB2420A

    1 Pages

  27. CB2410AC

    1 Pages

  28. CB1235A

    1 Pages

  29. CB243A

    1 Pages

  30. CB304A

    1 Pages

  31. CB363A

    1 Pages

  32. CB123A/48

    1 Pages

  33. CB1210A

    1 Pages

  34. CB123A

    1 Pages

  35. CB122410A

    1 Pages

  36. CB12245AJ

    1 Pages

  37. CB12245A

    1 Pages

  38. BAT12VRLA

    1 Pages

  39. BAT7.2VRLA

    1 Pages

  40. BAT3.4VRLA

    1 Pages

  41. BAT1.2VRLA

    1 Pages

  42. CBI2801224A

    2 Pages

  43. CBI4810A

    1 Pages

  44. CBI2420AP

    1 Pages

  45. CBI2420A

    1 Pages

  46. CBI1235A

    1 Pages

  47. CBI485A

    1 Pages

  48. CBI2410A

    1 Pages

  49. CBI245A

    1 Pages

  50. CBI243A

    1 Pages

  51. CBI1210A

    1 Pages

  52. CBI126A

    1 Pages

  53. CBI123A

    1 Pages