CBI2801224A-1

Technical features Thanks to the All In One units (DC-UPS), it will be possible to optimize power management. The available power is automatically allocated between load and battery, supplying power to the load is the first priority of the unit thus it is not necessary to double the power, because also the power going to the battery will go to the load if the load so requires. The maximum available current on the load output is 2 times the value of the device rated current In. We call “Battery Care” the concept base on algorithms that implement rapid and automatic charging, battery charge optimization during time, flat batteries recovery and real time diagnostic during installation and operation. The Real Time Auto-diagnostic system, monitoring battery faults such as, battery Sulfated, elements in short circuit, accidental reverse polarity connection, disconnection of the battery, they can easily be detected and removed by help of Blink Code of Diagnosis Led; during the installation and after sell. The continuous monitoring of battery efficiency, reduces battery damage risk and allows a safe operation in permanent connection. Each device is suited for all battery types, by means of jumpers it is possible setting predefined curves for Open Lead Acid, Sealed Lead Acid, Gel, Ni-Cd (option). They are programmed for two charging levels, boost and charge, but they can be changed to single charging level by the user. A rugged casing with bracket for DIN rail mounting provides IP20 protection degree. They are extremely compact and cost-effective. Norms and Certifications In Conformity to: EN60950 / UL60950-1 and CSA C22.2 No. 609501-07 (Information Technology Equipment Safety Part1: Safety EN IEC 62368-1: 2014/AC:2015; EN54-4 Fire Detection and fire alarm systems; 89/336/EEC; EMC Directive 2014/35/UE and Low voltage Directive 2014/35/UE; DIN41773 (Charging cycle); Emission: IEC 61000-6-4; Immunity: IEC 61000-6-2. CE. Climatic Data Ambient temperature (operation) -25 ÷ +70°C De Rating Ta > 55°C - 2.5% (In) /°C Ambient temperature Storage -40 ÷ +85°C Humidity at 25 °C no condensation 95% to 25°C Altitude: 0 to 2 000m - 0 to 6 560ft No restrictions Altitude: 2 000 to 6 000m - 6 560 to 20 De-rating 000ft 5°C/1000m Cooling Auto convention General Data Insulation voltage (IN/OUT) 3000 Vac Insulation voltage (Input / Earth, PE) 2000 Vac Insulation voltage (Out Load & Battery / 500 Vac Earth, PE) Insulation voltage (Out Load & Battery / 500 Vac Fault System & Main or Back Up terminal) Input: Single-phase 115 – 230 - 277 Vac Output Selectable Load:12 Vdc 15A; 24 Vdc 10A Output Battery charging: 12 Vdc 15A; 24 Vdc 10A Suited for the following battery types: Open Lead Acid, Sealed Lead Acid, Lead Gel, Lead Crystal, Ni-Cd, Li-Ion Automatic diagnostic of battery status. Charging curve IUoU, constant voltage and constant current Battery Life Test function (Battery Care) Four charging levels: Boost, Absorption, Float, Recovery Protected against short circuit and inverted polarity Signal output (contact free) for discharged or damaged battery Signal output (contact free) for mains or Back-UP Modbus RTU for all parameter battery and system Protection degree IP20 - DIN rail; Space saving Insulation voltage (Out Load & Battery / Aux2 & Aux3 / Fault System & Main or Back Up terminal) Leakage Current Protection Class (EN/IEC 60529) Reliability: MTBF IEC 61709 Pollution Degree Environment Connection Terminal Blocks screw Type Protection class (PE Connected) Dimensions (w-h-d) Weight Input Data Nominal Input Voltage Vac Voltage range Vac Inrush Current (Vn – In nom. Load) I2t Frequency Input Current (115 – 230 – 277 Vac) Internal fuse (not replaceable) External Fuse (recommended) MCB curve B Output Data (internal power supply) Select Output Voltage 12 or 24 Vdc. By: Continuous current (without battery) Continuous current ( With battery) Iload= In+ Ibatt Max. current Output Load (Main + Battery) Iload (4 sec.) Max. current Output Load (Back Up) Iload (4 sec.) Start From Battery Without Main (Remote Input Control) Time Buffering; min (switch output off without main input) Efficiency 230 Vac 24Vdc (rated current) Residual Ripple Turn-On delay after applying mains voltage Start up with Strong Load (capacitive load) Dissipation power load max (W) Short-circuit protection) Over Load protection Over Voltage Output protection Overheating Thermal protection Load Output 24 Vdc (jumper selection) Output voltage (at In) Nominal current In = Iload Threshold alarm Battery almost flat 500 Vac < 5mA IP20 > 300.000 h 2 2,5mm(24– 14AWG) I, with PE 100x115x135 mm 0.85 kg 115 – 230 – 277 90 – 135:180 – 305 £ 16 A £ 5 msec. 47 ÷ 63 Hz 5.5 – 3.0 – 2.0 6.3 A 16 A Jumper Enabling Iload=In 2xIn 3 x In max. 2 x In max. RTCONN (cable) Push Button 0.5; 2.5; 10; 15; 20; 30; 45; 60; ∞ ³ 91 % £ 80 mVpp 1 sec. (max) Yes, Unlimited 28 Yes Yes Yes (typ. 35 Vdc) Yes 22 - 28.8 Vdc 10 A ± 5% In 20 – 21 Vdc batt All specifications are subject to change wit

 Open the catalog to page 1
CBI2801224A-2

Float Charge Switch Configuration 25°C (V/cell): Max.Time Boost–Bulk charge (Typ. at IN) Min.Time Boost–Bulk charge (Typ. at IN) Charging current max Ibatt Charging current limiting Iadj Recovery Charge 12V / 24Vdc Reverse battery protection Sulfated battery check Short circuit Element Detection Quiescent Current on the battery Charging Curve automatic: IUoU Remote Input Control (RTCONN cable) Threshold alarm Battery almost flat 12V/24V LVD. (Protections against total Batt. discharge) 12V / 24V 19 – 20 Vdc batt Signal Input / Output (RJ45) Temp. Comp. Battery (with external probe) Follow Out...

 Open the catalog to page 2

All ADELSYSTEM catalogs and technical brochures

  1. CBI6048A

    2  Pages

  2. CBI2501224A

    2  Pages

  3. DFX60110

    1  Page

  4. BAT12Wh

    2  Pages

  5. DFX1524A

    1  Page

  6. DFX1512A

    1  Page

  7. DFX6012A

    1  Page

  8. DFX6024A

    1  Page

  9. CBI6024A

    1  Page

  10. CBI6012A

    1  Page

  11. CB6024A

    1  Page

  12. CB6012A

    1  Page

  13. FLEX50048A

    1  Page

  14. FLEX28048A

    1  Page

  15. FLEX17048A

    1  Page

  16. FLEX28012A

    1  Page

  17. FLEX17012A

    1  Page

  18. FLEX6012A

    1  Page

  19. FLEX28024B

    1  Page

  20. FLEX50024B

    1  Page

  21. FLEX17024B

    1  Page

  22. FLEX9024B

    1  Page

  23. FLEX50024A

    1  Page

  24. FLEX28024A

    1  Page

  25. FLEX17024A

    1  Page

  26. FLEX9024A

    1  Page

  27. FLEX6024A

    1  Page

  28. DPY353

    1  Page

  29. DPY351

    2  Pages

  30. MRF102

    1  Page

  31. CB2420A

    1  Page

  32. CB2410AC

    1  Page

  33. CB1235A

    1  Page

  34. CB243A

    1  Page

  35. CB304A

    1  Page

  36. CB363A

    1  Page

  37. CB123A/48

    1  Page

  38. CB1210A

    1  Page

  39. CB123A

    1  Page

  40. CB122410A

    1  Page

  41. CB12245AJ

    1  Page

  42. CB12245A

    1  Page

  43. BAT12VRLA

    1  Page

  44. BAT7.2VRLA

    1  Page

  45. BAT3.4VRLA

    1  Page

  46. BAT1.2VRLA

    1  Page

  47. CBI4810A

    1  Page

  48. CBI2420AP

    1  Page

  49. CBI2420A

    1  Page

  50. CBI1235A

    1  Page

  51. CBI485A

    1  Page

  52. CBI2410A

    1  Page

  53. CBI245A

    1  Page

  54. CBI243A

    1  Page

  55. CBI1210A

    1  Page

  56. CBI126A

    1  Page

  57. CBI123A

    1  Page

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.