CBI2801224A
2Pages

{{requestButtons}}

Catalog excerpts

CBI2801224A - 1

Technical features Thanks to the All In One units (DC-UPS), it will be possible to optimize power management. The available power is automatically allocated between load and battery, supplying power to the load is the first priority of the unit thus it is not necessary to double the power, because also the power going to the battery will go to the load if the load so requires. The maximum available current on the load output is 2 times the value of the device rated current In. We call “Battery Care” the concept base on algorithms that implement rapid and automatic charging, battery charge optimization during time, flat batteries recovery and real time diagnostic during installation and operation. The Real Time Auto-diagnostic system, monitoring battery faults such as, battery Sulfated, elements in short circuit, accidental reverse polarity connection, disconnection of the battery, they can easily be detected and removed by help of Blink Code of Diagnosis Led; during the installation and after sell. The continuous monitoring of battery efficiency, reduces battery damage risk and allows a safe operation in permanent connection. Each device is suited for all battery types, by means of jumpers it is possible setting predefined curves for Open Lead Acid, Sealed Lead Acid, Gel, Ni-Cd (option). They are programmed for two charging levels, boost and charge, but they can be changed to single charging level by the user. A rugged casing with bracket for DIN rail mounting provides IP20 protection degree. They are extremely compact and cost-effective. Norms and Certifications In Conformity to: EN60950 / UL60950-1 and CSA C22.2 No. 609501-07 (Information Technology Equipment Safety Part1: Safety EN IEC 62368-1: 2014/AC:2015; EN54-4 Fire Detection and fire alarm systems; 89/336/EEC; EMC Directive 2014/35/UE and Low voltage Directive 2014/35/UE; DIN41773 (Charging cycle); Emission: IEC 61000-6-4; Immunity: IEC 61000-6-2. CE. Climatic Data Ambient temperature (operation) -25 ÷ +70°C De Rating Ta > 55°C - 2.5% (In) /°C Ambient temperature Storage -40 ÷ +85°C Humidity at 25 °C no condensation 95% to 25°C Altitude: 0 to 2 000m - 0 to 6 560ft No restrictions Altitude: 2 000 to 6 000m - 6 560 to 20 De-rating 000ft 5°C/1000m Cooling Auto convention General Data Insulation voltage (IN/OUT) 3000 Vac Insulation voltage (Input / Earth, PE) 2000 Vac Insulation voltage (Out Load & Battery / 500 Vac Earth, PE) Insulation voltage (Out Load & Battery / 500 Vac Fault System & Main or Back Up terminal) Input: Single-phase 115 – 230 - 277 Vac Output Selectable Load:12 Vdc 15A; 24 Vdc 10A Output Battery charging: 12 Vdc 15A; 24 Vdc 10A Suited for the following battery types: Open Lead Acid, Sealed Lead Acid, Lead Gel, Lead Crystal, Ni-Cd, Li-Ion Automatic diagnostic of battery status. Charging curve IUoU, constant voltage and constant current Battery Life Test function (Battery Care) Four charging levels: Boost, Absorption, Float, Recovery Protected against short circuit and inverted polarity Signal output (contact free) for discharged or damaged battery Signal output (contact free) for mains or Back-UP Modbus RTU for all parameter battery and system Protection degree IP20 - DIN rail; Space saving Insulation voltage (Out Load & Battery / Aux2 & Aux3 / Fault System & Main or Back Up terminal) Leakage Current Protection Class (EN/IEC 60529) Reliability: MTBF IEC 61709 Pollution Degree Environment Connection Terminal Blocks screw Type Protection class (PE Connected) Dimensions (w-h-d) Weight Input Data Nominal Input Voltage Vac Voltage range Vac Inrush Current (Vn – In nom. Load) I2t Frequency Input Current (115 – 230 – 277 Vac) Internal fuse (not replaceable) External Fuse (recommended) MCB curve B Output Data (internal power supply) Select Output Voltage 12 or 24 Vdc. By: Continuous current (without battery) Continuous current ( With battery) Iload= In+ Ibatt Max. current Output Load (Main + Battery) Iload (4 sec.) Max. current Output Load (Back Up) Iload (4 sec.) Start From Battery Without Main (Remote Input Control) Time Buffering; min (switch output off without main input) Efficiency 230 Vac 24Vdc (rated current) Residual Ripple Turn-On delay after applying mains voltage Start up with Strong Load (capacitive load) Dissipation power load max (W) Short-circuit protection) Over Load protection Over Voltage Output protection Overheating Thermal protection Load Output 24 Vdc (jumper selection) Output voltage (at In) Nominal current In = Iload Threshold alarm Battery almost flat 500 Vac < 5mA IP20 > 300.000 h 2 2,5mm(24– 14AWG) I, with PE 100x115x135 mm 0.85 kg 115 – 230 – 277 90 – 135:180 – 305 £ 16 A £ 5 msec. 47 ÷ 63 Hz 5.5 – 3.0 – 2.0 6.3 A 16 A Jumper Enabling Iload=In 2xIn 3 x In max. 2 x In max. RTCONN (cable) Push Button 0.5; 2.5; 10; 15; 20; 30; 45; 60; ∞ ³ 91 % £ 80 mVpp 1 sec. (max) Yes, Unlimited 28 Yes Yes Yes (typ. 35 Vdc) Yes 22 - 28.8 Vdc 10 A ± 5% In 20 – 21 Vdc batt All specifications are subject to change wit

Open the catalog to page 1
CBI2801224A - 2

Float Charge Switch Configuration 25°C (V/cell): Max.Time Boost–Bulk charge (Typ. at IN) Min.Time Boost–Bulk charge (Typ. at IN) Charging current max Ibatt Charging current limiting Iadj Recovery Charge 12V / 24Vdc Reverse battery protection Sulfated battery check Short circuit Element Detection Quiescent Current on the battery Charging Curve automatic: IUoU Remote Input Control (RTCONN cable) Threshold alarm Battery almost flat 12V/24V LVD. (Protections against total Batt. discharge) 12V / 24V 19 – 20 Vdc batt Signal Input / Output (RJ45) Temp. Comp. Battery (with external probe) Follow...

Open the catalog to page 2

All ADELSYSTEM catalogs and technical brochures

  1. DFX6024A

    1 Pages

  2. DFX6012A

    1 Pages

  3. DFX1512A

    1 Pages

  4. DFX1524A

    1 Pages

  5. CBI6024A

    1 Pages

  6. CBI6012A

    1 Pages

  7. CB6024A

    1 Pages

  8. CB6012A

    1 Pages

  9. FLEX50048A

    1 Pages

  10. FLEX28048A

    1 Pages

  11. FLEX17048A

    1 Pages

  12. FLEX28012A

    1 Pages

  13. FLEX17012A

    1 Pages

  14. FLEX6012A

    1 Pages

  15. FLEX28024B

    1 Pages

  16. FLEX50024B

    1 Pages

  17. FLEX17024B

    1 Pages

  18. FLEX9024B

    1 Pages

  19. FLEX50024A

    1 Pages

  20. FLEX28024A

    1 Pages

  21. FLEX17024A

    1 Pages

  22. FLEX9024A

    1 Pages

  23. FLEX6024A

    1 Pages

  24. DPY353

    1 Pages

  25. DPY351

    2 Pages

  26. MRF102

    1 Pages

  27. CB2420A

    1 Pages

  28. CB2410AC

    1 Pages

  29. CB1235A

    1 Pages

  30. CB243A

    1 Pages

  31. CB304A

    1 Pages

  32. CB363A

    1 Pages

  33. CB123A/48

    1 Pages

  34. CB1210A

    1 Pages

  35. CB123A

    1 Pages

  36. CB122410A

    1 Pages

  37. CB12245AJ

    1 Pages

  38. CB12245A

    1 Pages

  39. BAT12VRLA

    1 Pages

  40. BAT7.2VRLA

    1 Pages

  41. BAT3.4VRLA

    1 Pages

  42. BAT1.2VRLA

    1 Pages

  43. CBI4810A

    1 Pages

  44. CBI2420AP

    1 Pages

  45. CBI2420A

    1 Pages

  46. CBI1235A

    1 Pages

  47. CBI485A

    1 Pages

  48. CBI2410A

    1 Pages

  49. CBI245A

    1 Pages

  50. CBI243A

    1 Pages

  51. CBI1210A

    1 Pages

  52. CBI126A

    1 Pages

  53. CBI123A

    1 Pages