Catalog excerpts
Technical features Thanks to the All-In-One units “DC-UPS” it is possible to optimize the power management, today implemented with two Outputs: one Dynamic and one Static. The available power is automatically shared between load and battery. Supplying power to the load is the top priority of the unit: it is not necessary to double the power of the device, because also the power going to the battery will be steered to the load if the load so requires. The maximum available current at the load output is twice the value of the device rated current In. We call “Battery Care” the concept based on algorithms that implement rapid and automatic charging, battery charging optimization during time, flat batteries recovery and real time diagnostic during installation and operation. Battery faults such as sulphated battery, battery cells in short circuit, accidental battery connection with reversed polarity, disconnection of the battery and more can easily be detected and removed with the aid of the blink code of the diagnosis LED both during the installation and normal operation. The continuous monitoring of the battery status reduces battery damage risk and allows a safe operation in a permanent and unattended system. The battery state-of-health is continuously monitored providing an early diagnostic of battery wear thus allowing a preventive maintenance to be undertaken. Each device is suited for all battery types: by means the user interface it is possible to set predefined charging profiles for Open Lead Acid, Sealed Lead Acid, Gel, NiCd/NiMH with five charging stages, Recovery, Bulk/Boost, Absorption, multimode Float and Refresh, that can be customized by the user using the Modbus RTU interface. Periodic purification can be configured to regularly exercise the battery thus helping prevent sulphation and wear. A rugged casing with bracket for DIN rail mounting provides IP20 protection degree. The CBI2501224A is a feature-rich and heavyduty unit which is extremely compact in size and very a costeffective power management solution. Power Management and controls The new line CBIPlus provide two Outputs: the first is a normal output connected to the internal power supply, the second output is controlled by the internal device and it is configurable, we call “Dynamic Output”. This Dynamic Output can be configured via Modbus RTU as Fuse Breaker, Soft Start, Fade-in and Fade-out, On/Off, PC shutdown and much more. Interconnections The CBI2501224A is equipped with a CAN-based ADELBUS interface which allows the plug-and-play connection of Adelsystem devices Input: Single-phase 100 – 240 - 277 Vac / 140 – 340 Vdc Output Selectable Load: 12 Vdc 10A; 24 Vdc 10A Two utput: 1 Continuous, 1 Dynamic: On/Off by Modbus Output Battery charging: 12 Vdc 10A; 24 Vdc 10A Two load outputs: one static; one dynamic for: On/Off, Dimmer (LED, DC brush motors), Fuse Breaker, PC shutdown and more Modbus RTU for Monitoring, Configuration, History and Alarms. ADELBus: integrated monitoring and control of ADELSystem devices such as MRF10x e-Fuses and display. Suitable for the following battery types: Open Lead Acid, Sealed Lead Acid (AGM/VRLA), lead Gel, Li-Ion and NiCd/NiMH Battery Care: Automatic diagnostic of battery state-of-charge (SoC) and state-of-health (SoH). Charging curve IUoU, constant voltage and constant current. Five charging levels: Recovery, Boost, Absorption, Float (Forced trickle / Forced float / Auto float-trickle), and Refresh Battery purification for battery reinvigoration Protected against short circuit and reversed polarity Signal output (contact free) for: discharged or damaged battery, Mains or Back-up, rectifier failure Protection degree IP20 - DIN rail; Space saving such as electronic fuses and displays enabling their control and monitoring. Moreover, an electrically-isolated RS485-based standard Modbus RTU interface allows a PC or RTU to monitor and control the CBI2501224A along with the Adelbus devices connected to it. Such integration with all the accessories provided by ADELSYSTEM allows the development of a truly independent system for electrical continuity. At the same time, it allows monitoring and control all parameters in the system by means of application tools. ADELSystem allows you to implement very simple but sophisticated monitoring and control for your energy system and opens your mind to new ways to approach your applications. Norms and Certifications In Conformity to: EN60950 / UL60950-1 and CSA C22.2 No. 609501-07 (Information Technology Equipment Safety Part1: Safety EN IEC 62368-1: 2014/AC:2015; EN54-4 Fire Detection and fire alarm systems; 89/336/EEC EMC Directive; 2014/35/UE (Low Voltage); DIN41773 (Charging cycle); Emission: IEC 61000-6-4; Immunity: IEC 61000-6-2. CE. Climatic Data Ambient temperature (operation) -25 ÷ +80°C De-rating Tamb > 60°C - 2.5% (In) /°C Ambient temperature Storage -40 ÷ +85°C Humidity at 25 °C no condensation 95% to 25°C Altitude: 0 - 6000m / 0 – 20000ft No restrictions Over voltage category IEC62103, EN50178 III Altitude < 2000m Over voltage category IEC62103, EN50178 II Altitude > 2000m Cooling Auto convection General Data Insulation voltage (IN/OUT) 4000 Vac Insulation voltage (Input / Earth, PE) 2500 Vac Insulation voltage (Out Load & Battery / 1000 Vac Earth, PE) Insulation voltage (Out Load & Battery / 1000 Vac Fault System & Main or Back Up terminal) Modbus RTU interface insulation Functional only Leakage Current < 5mA Protection Class (EN/IEC 60529) IP20 Reliability: MTBF IEC 61709 > 300000 h Pollution Degree Environment 2 Input and output Connections: terminal 2 mm Blocks Push-in type (24–12AWG) Signal Conn
Open the catalog to page 1Protection class (PE Connected) Dimensions (w-h-d) Weight Input Data Nominal Input Voltage Vac Input Current at 115 – 240 – 277 Vac (A) Voltage range Vac Voltage range Vdc Input Current at 110 – 340 Vdc (A) Inrush Current (Vn – In nom. Load) I2t Power Factor, typ. at full load Frequency Input Current (115 – 240 – 277 Vac) Internal fuse (not replaceable) External Fuse (recommended) MCB Output Data (internal power supply) Select Output Voltage 12 or 24 Vdc. Continuous current (without battery) Continuous current ( With battery) Iload= In+ Ibatt Max. current Output Load (Main + Battery) Iload...
Open the catalog to page 2All ADELSYSTEM catalogs and technical brochures
-
DFX60110
1 Pages
-
BAT12Wh
2 Pages
-
DFX6024A
1 Pages
-
DFX6012A
1 Pages
-
DFX1512A
1 Pages
-
DFX1524A
1 Pages
-
CBI6024A
1 Pages
-
CBI6012A
1 Pages
-
CB6024A
1 Pages
-
CB6012A
1 Pages
-
FLEX50048A
1 Pages
-
FLEX28048A
1 Pages
-
FLEX17048A
1 Pages
-
FLEX28012A
1 Pages
-
FLEX17012A
1 Pages
-
FLEX6012A
1 Pages
-
FLEX28024B
1 Pages
-
FLEX50024B
1 Pages
-
FLEX17024B
1 Pages
-
FLEX9024B
1 Pages
-
FLEX50024A
1 Pages
-
FLEX28024A
1 Pages
-
FLEX17024A
1 Pages
-
FLEX9024A
1 Pages
-
FLEX6024A
1 Pages
-
DPY353
1 Pages
-
DPY351
2 Pages
-
MRF102
1 Pages
-
DC-UPS Catalogue
12 Pages
-
POWER SUPPLY FLEX Catalogue
2 Pages
-
BATTERY HOLDER 12V
2 Pages
-
CB2420A
1 Pages
-
CB2410AC
1 Pages
-
CB1235A
1 Pages
-
CB243A
1 Pages
-
CB304A
1 Pages
-
CB363A
1 Pages
-
CB123A/48
1 Pages
-
CB1210A
1 Pages
-
CB123A
1 Pages
-
CB122410A
1 Pages
-
CB12245AJ
1 Pages
-
CB12245A
1 Pages
-
BAT12VRLA
1 Pages
-
BAT7.2VRLA
1 Pages
-
BAT3.4VRLA
1 Pages
-
BAT1.2VRLA
1 Pages
-
CBI2801224A
2 Pages
-
CBI4810A
1 Pages
-
CBI2420AP
1 Pages
-
CBI2420A
1 Pages
-
CBI1235A
1 Pages
-
CBI485A
1 Pages
-
CBI2410A
1 Pages
-
CBI245A
1 Pages
-
CBI243A
1 Pages
-
CBI1210A
1 Pages
-
CBI126A
1 Pages
-
CBI123A
1 Pages