Overview: The CB6012A is a single-phase power supply and battery charger designed for various battery types including Open Lead Acid, Sealed Lead Acid, Lead Gel, and Ni-Cd. It features automatic diagnosis and battery status monitoring with a charging curve of IUoU, which includes constant current and constant voltage phases.
Specifications: The input voltage range is 90 – 305 Vac with a nominal input voltage of 100 – 240 – 277 Vac. The output is 12 Vdc at 5A. The device is protected against short circuits, inverted polarity, and overloads, and has a protection degree of IP20. It can be mounted on a DIN rail or wall.
Technical Features: The CB series employs switching technology and a battery care philosophy, offering multi-stage, fully automatic battery charging. It includes real-time diagnostics and self-diagnosis systems to detect battery faults. The device supports preset curves for different battery types and features a sturdy housing for mounting.
Input Data: The device has an inrush current of ≤ 50 A and operates at a frequency of 47 – 63 Hz ±6%. The internal fuse is rated at 2.5 A, with a recommended external fuse of 10 A (MCB curve C).
Battery Charger Output: Fast/Boost charge voltages are 14.1 V for Lead and 14.5 V for Ni-Cd. Recovery charge ranges from 2 – 10 V with a charging current of 5 A ± 5%. The device includes reverse polarity protection and end-of-charge control.
Generic Output Data: The maximum time for bulk-absorption charge is 16 hours, with a minimum of 2 minutes for bulk charge. Float charge voltages vary by battery type, and the device features short-circuit, overload, and thermal protection.
Connection and Monitoring: The device provides signal outputs for main or backup input power, low battery, and fault battery states. The maximum current for signal output is 30 Vdc 1 A or 60 Vac 1 A.
General Data: The insulation voltage is 4000 Vac, with a protection class of IP20. The device has a reliability MTBF of over 300,000 hours and is made of polycarbonate. It operates in temperatures from -25 to +70°C and can be stored from -40 to +85°C.
Norms and Certifications: The device conforms to the Low Voltage Directive 2014/35/UE and the Electromagnetic Compatibility Directive 2014/30/UE. It is pending UL 1236 recognition.
Charging: The charging type follows the IUoU stabilized voltage and current method. The charging status and self-diagnosis are indicated by LED codes, with different blink rates for recovery, boost, absorption, and float charging states.
See more

Catalog excerpts

CB6012A-1

Technical features The CB series is a "Switching Technology" and "Battery Care Philosophy" that has been part of ADEL's core system know-how for years, leading to the development of this advanced, multi-stage, fully automatic battery charging method suitable for meeting the most advanced requirements of battery manufacturers. The Battery Care concept is based on algorithms that implement rapid and automatic charging, optimization of battery charging over time, recovery of discharged batteries, and real-time diagnostics during installation and operation. The real-time self-diagnosis system, which monitors battery faults such as shorted elements, accidental reverse polarity connections, and battery disconnections, can be easily detected and removed with the help of the flashing code of the diagnosis LED; during installation and after sale. Each device is suitable for all types of batteries. Preset curves can be set for open lead acid, sealed lead acid, gel, Ni-Cd. A sturdy housing with bracket for DIN rail and wall mounting. Internal Fuse External Fuse (recommended) Battery Charger Output Fast/Boost Charge Recovery Charge Charging Current In End of charging current to Float (Bulk & Absorption charge) Charging current limiting Iadj Quiescent Current (Input main Voltage ON) Quiescent Current (Input main Voltage OFF) Remote Charge Input Control Fast/Boost charge Power Supply function can be configured pushing the button at switch-on Efficiency (50% of In) Dissipation Power load max (W) Residual Ripple Charging Curve automatic: IUoU Short-circuit protection) Over Load protection Overheating Thermal Protection Over Voltage Output protection Insulation voltage (In / Out) Protection Class (EN/IEC 60529) Protection class Reliability: MTBF IEC 61709 Pollution Degree Environment Connection Terminal Blocks screw Type Housing material Dimensions (w-h-d) Weight Climatic Data Ambient temperature Operation Ambient temperature Storage Humidity at 25 °C no condensation Cooling Vibration IEC60068-2-6 Conforming to Low Voltage Directive (LVD) 2014/35/UE Electrical safety: IEC/EN 62368-1 Conforming to Electromagnetic Compatibility (EMC) Directive 2014/30/UE Emission: IEC/EN 61000-6-3 Immunity: IEC/EN 61000-6-2 UL 1236 Recognition Pending Generic Output Data Max. time Bulk-Absorption Charge (typ. At In) Min. time Bulk Charge (typ. At In) Float Charge: Battery type can be configured pushing the button at switch-on. (V/cell) Battery Tester Battery Detection of element in short circuit Reverse polarity protection Battery Disconnected (Protection No Spark) Battery Voltage Wrong End of charge control Signal Output (free switch contact) Main or Backup Input Power Low Battery Fault Battery Type of Signal Output Contact (free switch contact) Max. current can be switched (EN60947.4.1): Max. DC1: 30 Vdc 1 A; AC1: 60 Vac 1A Min.1mA at 5 Vdc General Data Input Data Nominal Input Voltage UL ratings Input Voltage range Inrush Current Frequency Input Current Input: Single-phase 100 – 240 - 277 Vac Output: 12 Vdc 5A Power Supply Function Suited for the following battery types: Open Lead Acid, Sealed Lead Acid, Lead Gel, Ni-Cd Battery Care: automatic diagnosis and battery status Charging curve IUoU: constant current and constant voltage High efficiency with quasi-resonant switching technology Charging type: Boost, Absorption, Float, Recovery. Protected against short circuit, inverted polarity, over Load. Signal output (Free Switch Contact): Fault battery state, Mains/Back-Up. Protection degree IP20 DIN rail or Wall Mount 16 h 2 min. 2.23 V (Open Lead) 2.25 V (AGM) 2.30 V (Gel) 1.4V (Ni-Cd) “10 cell” 300 mA No  5mA 0mA (Vbat < 26.3V) Terminal Block Contact Yes The charging type is IUoU stabilized voltage and current in accordance with DIN41773. The battery charging status and self-diagnosis of the systems are identified by a flashing code on the diagnosis LED and the battery fault LED: State Charging Type Auto Diagnosis Recovery Boost – Bulk Absorption Float Reverse polarity Battery No connect Element in Short C. Replace Battery LED Green Charging State 5 Blink/sec 2 Blink/sec 1 Blink/sec 1 Blink/2 sec LED Orange Battery Fault

 Open the catalog to page 1

All ADELSYSTEM catalogs and technical brochures

  1. CBI6048A

    2  Pages

  2. CBI2501224A

    2  Pages

  3. DFX60110

    1  Page

  4. BAT12Wh

    2  Pages

  5. DFX1524A

    1  Page

  6. DFX1512A

    1  Page

  7. DFX6012A

    1  Page

  8. DFX6024A

    1  Page

  9. CBI6024A

    1  Page

  10. CBI6012A

    1  Page

  11. CB6024A

    1  Page

  12. FLEX50048A

    1  Page

  13. FLEX28048A

    1  Page

  14. FLEX17048A

    1  Page

  15. FLEX28012A

    1  Page

  16. FLEX17012A

    1  Page

  17. FLEX6012A

    1  Page

  18. FLEX28024B

    1  Page

  19. FLEX50024B

    1  Page

  20. FLEX17024B

    1  Page

  21. FLEX9024B

    1  Page

  22. FLEX50024A

    1  Page

  23. FLEX28024A

    1  Page

  24. FLEX17024A

    1  Page

  25. FLEX9024A

    1  Page

  26. FLEX6024A

    1  Page

  27. DPY353

    1  Page

  28. DPY351

    2  Pages

  29. MRF102

    1  Page

  30. CB2420A

    1  Page

  31. CB2410AC

    1  Page

  32. CB1235A

    1  Page

  33. CB243A

    1  Page

  34. CB304A

    1  Page

  35. CB363A

    1  Page

  36. CB123A/48

    1  Page

  37. CB1210A

    1  Page

  38. CB123A

    1  Page

  39. CB122410A

    1  Page

  40. CB12245AJ

    1  Page

  41. CB12245A

    1  Page

  42. BAT12VRLA

    1  Page

  43. BAT7.2VRLA

    1  Page

  44. BAT3.4VRLA

    1  Page

  45. BAT1.2VRLA

    1  Page

  46. CBI2801224A

    2  Pages

  47. CBI4810A

    1  Page

  48. CBI2420AP

    1  Page

  49. CBI2420A

    1  Page

  50. CBI1235A

    1  Page

  51. CBI485A

    1  Page

  52. CBI2410A

    1  Page

  53. CBI245A

    1  Page

  54. CBI243A

    1  Page

  55. CBI1210A

    1  Page

  56. CBI126A

    1  Page

  57. CBI123A

    1  Page

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.