CB1210A - 1

Technical features Input Data The CB series is a “Switching technology” and “Battery Care philosophy”, since years parts of the core know-how at ADEL system, led to the development of this advanced multi-stage battery charging method, completely automatic and suited to meet the most advanced requirements of battery manufacturers. The Battery Care concept is base on algorithms that implement rapid and automatic charging, battery charge optimization during time, flat batteries recovery and real time diagnostic during installation and operation. The Real Time Autodiagnostic system, monitoring battery faults such as, elements in short circuit, accidental reverse polarity connection, disconnection of the battery, they can easily be detected and removed by help of Blink Code of Diagnosis Led; during the installation and after sell. Each device is suited for all battery types, by means of jumpers it is possible setting predefined curves for Open Lead Acid, Sealed Lead Acid, Gel, NiCd(option). They are programmed for two charging levels, boost and trickle. A rugged casing with bracket for DIN rail mounting provide IP20 protection degree. General Data Insulation voltage (In /Out) Insulation voltage (In / PE) Insulation voltage (Out / PE) Protection Class (EN/IEC 60529) Protection class Reliability: MTBF IEC 61709 Pollution Degree Environment Connection Terminal Blocks screw Type Dimensions (w-h-d) Weight 3000 Vac 1605 Vac 500 Vac IP20 I, with PE connected > 300.000 h 2 2,5mm(24–14AWG) 65x115x135 mm 0.65 Kg approx Climatic Data Ambient temperature (operation) De Rating Ta > 50°C Ambient temperature Storage Humidity at 25 °C no condensation Cooling Norms and Certifications In Conformity to: IEC/EN 60335-2-29 Battery chargers; EN60950 / UL60950-1 and CSA C22.2 No. 60950-1-07 (Information Technology Equipment) – Safety – Part1:General Requirement. Electrical safety; EN54-4 Fire Detection and fire alarm systems; 89/336/EEC EMC Directive; 2014/35/UE (Low Voltage); DIN41773 (Charging cycle); Emission : IEC 61000-6-4; Immunity: IEC 61000-6-2. CE. Signal Output (free switch N°2 contact) Main or Backup Power Low Battery Fault Battery Input: Single-phase 115 ÷ 277 Vac Output: Battery charging 12 Vdc; 10 A Suited for the following battery types: Open Lead Acid, Sealed Lead Acid, lead Gel and Ni-Cd (option) Automatic diagnostic of battery status. Charging curve IUoUo, constant voltage and current Switching technology, output voltage 14.4 Vdc Three charging levels: Boost, Trickle, Recovery. Protected against short circuit, inverted polarity, over Load. Signal output (contact free) for fault battery state Protection degree IP20 - DIN rail Nominal Input Voltage (2 x Vac) Input Voltage range (Vac) Inrush Current (Vn and In Load) I2t Frequency Input Current (115 – 230 Vac) Internal Fuse External Fuse (recommended) Battery Output (Battery Care) Boost charge (25 °C) (Typ. at In) Max. time Bust Charge (tpy. At In) Min. time Bust Charge (tpy. At In) Trickle charge (25 °C) (Typ. at In) Jumper Configuration battery type (V cell) Ni-Cd (optional) Recovery Charge Charging. Max Ibatt (In) Efficiency (50% of In) Dissipation power load max (W) Charging current limiting Iadj Quiescent Current Charging Curve automatic: IUoUo Detection of element in short circuit Short-circuit protection) Over Load protection Over Voltage Output protection Charging Aautomatic multi-stage charging and real time diagnostic allow fast recharge and recovery of deep discharged batteries, adding value and reliability to the system hosting. Type of charging it is Voltages and current stabilized IUoUo. The state of charging battery and Autodiagnosis of the systems are identified by a flashing code on a Diagnosis LED and Fault Battery LED: State Diagnosis LED Battery Fault LED Trickle 1 Blink/sec OFF Charging Boost 2 Blink/sec OFF Type Recovery 5 Blink/sec OFF Reverse polarity ON 1Blink Battery No connect ON 2Blink Auto ON diagnosis Element in Short C. 3Blink Replace Battery ON 5Blink Type of Signal Output Contact Max. current can be switched (EN60947.4.1): Max. DC1: 30 Vdc 1 A; AC1: 60 Vac 1A Min.1mA at 5 Vdc Resistive load Min. load

Open the catalog to page 1

All ADELSYSTEM catalogs and technical brochures

  1. DFX6024A

    1 Pages

  2. DFX6012A

    1 Pages

  3. DFX1512A

    1 Pages

  4. DFX1524A

    1 Pages

  5. CBI6024A

    1 Pages

  6. CBI6012A

    1 Pages

  7. CB6024A

    1 Pages

  8. CB6012A

    1 Pages

  9. FLEX50048A

    1 Pages

  10. FLEX28048A

    1 Pages

  11. FLEX17048A

    1 Pages

  12. FLEX28012A

    1 Pages

  13. FLEX17012A

    1 Pages

  14. FLEX6012A

    1 Pages

  15. FLEX28024B

    1 Pages

  16. FLEX50024B

    1 Pages

  17. FLEX17024B

    1 Pages

  18. FLEX9024B

    1 Pages

  19. FLEX50024A

    1 Pages

  20. FLEX28024A

    1 Pages

  21. FLEX17024A

    1 Pages

  22. FLEX9024A

    1 Pages

  23. FLEX6024A

    1 Pages

  24. DPY353

    1 Pages

  25. DPY351

    2 Pages

  26. MRF102

    1 Pages

  27. CB2420A

    1 Pages

  28. CB2410AC

    1 Pages

  29. CB1235A

    1 Pages

  30. CB243A

    1 Pages

  31. CB304A

    1 Pages

  32. CB363A

    1 Pages

  33. CB123A/48

    1 Pages

  34. CB123A

    1 Pages

  35. CB122410A

    1 Pages

  36. CB12245AJ

    1 Pages

  37. CB12245A

    1 Pages

  38. BAT12VRLA

    1 Pages

  39. BAT7.2VRLA

    1 Pages

  40. BAT3.4VRLA

    1 Pages

  41. BAT1.2VRLA

    1 Pages

  42. CBI2801224A

    2 Pages

  43. CBI4810A

    1 Pages

  44. CBI2420AP

    1 Pages

  45. CBI2420A

    1 Pages

  46. CBI1235A

    1 Pages

  47. CBI485A

    1 Pages

  48. CBI2410A

    1 Pages

  49. CBI245A

    1 Pages

  50. CBI243A

    1 Pages

  51. CBI1210A

    1 Pages

  52. CBI126A

    1 Pages

  53. CBI123A

    1 Pages