MSX-E3601 / MSX-E3601-2
4Pages

{{requestButtons}}

Catalog excerpts

MSX-E3601 / MSX-E3601-2 - 1

Ethernet system for the acquisition of dynamic signals 8 or 2 SE/diff. inputs, 24-bit, simultaneous acquisition Temperaturbereich -40 °C bis 85 °C MSX-E3601 / MSX-E3601-2 8 or 2 SE/diff. inputs, 24-bit Simultaneous acquisition 8 or 2 current sources for ICP® or IEPE sensors Onboard calibration 24 V digital trigger input Integrated Ethernet switch Cascadable, can be synchronised in the µs range *Operating temperature in µs-Bereich 24 V digital trigger input ARM®9 32-bit processor 64 MB onboard SDRAM for storing data Robust standardized metal housing Power Save Mode: Reduced power consumption when Mehr Info auf no acquisition runs www.addi-data.com Analog inputs • 8 or 2 SE or diff. inputs, 24-bit, AC/DC coupling • One A/D converter per channel: simultaneous acquisition on all analog inputs • Sampling rate up to 128 kHz Kaskadierbar • Antialiasing filter Edelstahl • BNC female connector: - inner conductor for positive input - outer conductor for negative input (diff) or GND (SE) • Gain x1, x10, x100 Synchronisierbar in µs-Bereich Current sources Edelstahl • 8 or 2 current sources for the direct connection of ® ICP sensors (integrated circuit piezoelectric) or IEPE sensors (integrated electronics piezoelectric) • 4 mA typ., 24 V max. Safety features • • • • • Mehr Info auf www.addi-data.com More information on www.addi-data.com Kaskadierbar Edelstahl Drivers and samples Find software for the MSX-E systems at: www.addi-data.com/ downloads Synchronisierbar in µs-Bereich Edelstahl Status LEDs for fast error diagnostics O ptical isolation I nput filters O vervoltage protection ± 40 V I nternal temperature monitoring Fast 24 V trigger input Ethernet switch with 2 ports Synchronisation/trigger In/Out Line in for 24 V supply and cascading Communication interfaces • Web server (configuration and monitoring) • Command server SOAP for transferring commands • Data server (TCP/IP or UDP socket) for sending acquisition data • Event server (TCP/IP socket) for sending system events (Diagnostics such as temperature, short-circuits ...) info@addi-data.com www.addi-data.com Synchronisation/time stamp Time stamp Several MSX-E systems can be synchronised with one another in the µs range through a synchro connection. This allows to start a synchronous data acquisition, to generate trigger events and to synchronise the time on several MSX-E systems. Furthermore, the systems have a time stamp that logs the point in time at which the data was acquired by the system. System B Counter Digital I/O System MSX-E1701 Analog Input System MSX-E3011 Without synchro: TSAx ≠ TSBx With synchro: TSAx = TSBx The combination of synchronisation and time stamp (TS) allows the clear allocation of signals that were captured by several systems. Acquisition with synchro Acquisition without synchro Value Ax1 Value Ax2 Value Axn

Open the catalog to page 1
MSX-E3601 / MSX-E3601-2 - 2

Intelligent Ethernet systems, analog – MSX-E3601 / MSX-E3601-2 Acquisition triggered through trigger or synchro input In sequence mode, a list of channels is acquired. Thereby, the single measurement rows are stored one after another. The client receives the acquired values asynchronously to the acquisition through a socket connection. In the sequence mode, the measurement values are read in chronological order, this means the oldest values are read first. The acquisition can be effected continuously, with or without delay or in combination with a hardware or synchro trigger. Sequence mode...

Open the catalog to page 2
MSX-E3601 / MSX-E3601-2 - 3

Intelligent Ethernet systems – MSX-E3601 / MSX-E3601-2 The ConfigTools program allows an easy administration of the MSX-E systems. These are automatically detected in the network. ConfigTools consists of common and specific functions. In addition, with ConfigTools, the complete configuration of a MSX-E system can be saved and transferred to another system of the same type (clone function). Status LEDs 8 analog inputs, BNC female connector: - inner conductor for pos. input - uter conductor for neg. input o (diff) or GND (SE) ConfigTools is included in the delivery. Change of IP address...

Open the catalog to page 3
MSX-E3601 / MSX-E3601-2 - 4

Analog inputs Number of inputs: Input type: Intelligent Ethernet systems - MSX-E3601 / MSX-E3601-2 8, 1 AD converter per channel 2, simultaneous acquisition, 1 AD converter per channel single-ended or differential (software-configurable) Phase mismatch: Between channels 0-1,2-3, 4-5, 6-7, with gain x1 > 104 dB short input, f = 100 Hz short input, fi 50 Q input, f 50 Q input, fin = 1 kHz Between channels 1-2, 3-4, 5-6, 7-8, with gain x1 ± 0.001° fin < 100 Hz Input ranges Gain x1: Gain x10: Gain x100: SE ± 10 V single-ended ± 1 V single-ended ± 0.1 V single-ended Diff. ± 5 V differential ±...