Ethernet multifunction counter system - 1

Ethernet multifunction counter system 4 EnDat counter inputs, 16 digital I/O, 24 V 4 EnDat 2.2 inputs 16 digital I/O, 24 V, with status LEDs V digital trigger input Integrated Ethernet switch On request: Compare logic for synchro trigger signal Synchronisierbar synchronised in in the µs range µs-Bereich *Operating temperature Synchronisation/time stamp Synchronisierbar Mehr Info auf • 24 V digital trigger input in µs-Bereich Time stamp www.addi-data.com ® • ARM 9 32-bit processor Several MSX-E systems can be synchronised with one an• 64 MB onboard SDRAM for storing data other in the µs range through a synchro connection. • Robust standardized metal housing This allows to start a synchronous data acquisition, to • Power Save Mode: Reduced power consumption when generate trigger events and to synchronise the time on no acquisition runs Mehr Info auf several MSX-E systems. Furthermore, the systems have a www.addi-data.com Kaskadierbar time stamp that logs the point in time at which the data Safety features Edelstahl • Status LEDs for fast error diagnostics was acquired by the system. • Optical isolation 1000 V System B System A • Input filters Synchronisation TSBx TSAx Synchronisierbar Kaskadierbar in µs-Bereich • 8-pin M12 female connectors Edelstahl Edelstahl • 4 x EnDat counter inputs for the acquisition of EnDat encoders • Max. clock frequency 4.5 MHz • Voltage supply of the EnDat encoders via M12 female Synchronisierbar Value Ax1 Value Ax2 Value Axn Value Bx1 Value Bx2 Value Bxn connectors: 5 V ±10%µs-Bereich in Without synchro: TSAx ≠ TSBx • Output of the values Edelstahl value as raw With synchro: TSAx = TSBx or position value (mm or °) The combination of synchronisation and time stamp (TS) • Communication LED for each EnDat input allows the clear allocation of signals that were captured Interfaces by several systems. Sensor inputs Analog Input System MSX-E3011 Counter Digital I/O System MSX-E1701 Mehr Info auf www.addi-data.com More information at www.addi-data.com Fast 24 V trigger input Ethernet switch with 2 ports Synchronisation/trigger In/Out Line in for 24 V supply and cascading Acquisition with synchro Kaskadierbar Edelstahl Synchronisierbar in µs-Bereich Edelstahl Drivers and samples Find software for the MSX-E systems at: www.addi-data.com/ downloads info@addi-data.com www.addi-data.com Communication interfaces • Web server (configuration and monitoring) • Command server SOAP for transferring commands • Data server (TCP/IP or UDP socket) for sending acquisition data • Event server (TCP/IP socket) for sending system events (Diagnostics such as temperature, short-circuits ...) • Command server Modbus TCP and Modbus (UDP) for sending commands Acquisition without synchro Value Ax1 Value Ax2 Value Axn

Open the catalog to page 1
Ethernet multifunction counter system - 2

Intelligent Ethernet systems, counter – MSX-E1731 EnDat EnDat is a bidirectional synchronous-serial ­nterface for position measurement devices. This interface allows to read out absoi lute position values and parameters, to write status and initialisation registers and to transfer additional information about the position value. In addition, ADDI-DATA EnDat 2.2 solutions support the evaluation of diagnostic values and access to the OEM memory. Data is transferred serially. • • • • • • • • Fast data transfer Signal delay time compensation High contour accuracy High transmission safety No...

Open the catalog to page 2
Ethernet multifunction counter system - 3

Intelligent Ethernet systems, counter – MSX-E1731 The ConfigTools program allows an easy administration of the MSX-E systems. These are automatically detected in the network. ConfigTools consists of common and specific functions. In addition, with ConfigTools, the complete configuration of a MSX-E system can be saved and transferred to another system of the same type (clone function). LEDs for counter inputs ConfigTools is included in the delivery. DUAL LEDs for digital I/O Status LEDs 2 x voltage supply, 24 V IN/OUT, optically isolated Change of IP address Display of web interface Firmware...

Open the catalog to page 3
Ethernet multifunction counter system - 4

Intelligent Ethernet systems, counter - MSX-E1731 SpecificationsCounter inputs Input type: EnDat 2.2 Differential inputs: Complies with the EIA standards RS422A Input type: Differential Common mode range: +12 / -7 V Input sensitivity: ± 200 mV Number of inputs: max. 16, 2 per M12 female connector, common ground acc. to IEC 1131-2 Overvoltage protection: 30 V Optical isolation: 1000 V through opto-couplers Input voltage: from 0 to 30 V Input impedance: > 1 MQ Logic input levels: UH (max):30 V typ. UH (min): 18 V typ. UL (max): 16 V typ. UL (min): 0 V...